Low Frequency Online UPS (Uninterrupted Power Supply) WZZ
Applications of Low Frequency Online UPS (Uninterrupted Power Supply):
Our low frequency online UPS are widely used to protect computer and peripheraldevices, date centers, telecommunications facilities, medical equipments, firefighting lighting and many other electrical equipments where an unexpectedpower disruption could cause serious business disruption or data loss etc.;
Features of LowFrequency Online UPS (Uninterrupted Power Supply):
1. High quality electric power supply: IGBT 20KHz SPWM modulate; over 340control points for each cycle wave;
2. Short circuit protection is available in our low frequency online UPS;
3. Parallel balanced current technology is adopted to enhance the performancereliability of our uninterrupted power supply;
4. On-line mode battery testing: we can test the battery quality when the UPSis power on;
5. 500 times of electric power supply abnormality can be memorized; and ifconnected with computers, more power supply abnormality can be recorded forconvenient maintenance and repairing. And the abnormality record could also besent out through emails.
6. 100% unbalance protection design: WZZ series low frequency online UPS canwork normally under phase loss conditions; and the output voltage stability is±1%;
7. Intelligent battery charging and management: floating charging and equalizedcharging are both available; alternative type constant voltage and constantcurrent intelligent management system is available to protect the battery andprolong battery life.
8. Digitalized CPU control: several modules of microprocessors are adopted todrive the system directly and as a result simplified the analog line; and theCPU load utilization, voltage and current utilization etc. can be calculated.
9. Dry contact signal, monitoring panel signal, RS-232 to RS-485 or RS-442signals are all available in this electric power supply product.
10. Communication interface is equipped, so out uninterrupted power supply canbe linked to computer and realize remote monitoring through internet.
Parameters of LowFrequency Online UPS (Uninterrupted Power Supply):
Model | WZZ-10 | WZZ-20 | WZZ-30 | WZZ-40 | WZZ-50 | WZZ-60 | WZZ-70 | WZZ-80 | WZZ-90 | WZZ-100 | WZZ-110 | WZZ-120 | |
Performance Parameters of Low Frequency Online UPS | |||||||||||||
UPS type | Low Frequency Online UPS | ||||||||||||
Rated capacity | 10K | 15K | 20K | 30K | 40K | 50K | 60K | 80K | 100K | 120K | 150K | 200K | |
Input | Voltage | 380Vac ± 20%3P4W G | |||||||||||
Frequency | 50Hz ± 5% | ||||||||||||
Out put | Steady voltage | 380Vac ± 1% 3P4W G | |||||||||||
Transient voltage | Load change: 0 – 100% – 0<±5%; | ||||||||||||
Frequency | 50Hz ± 0.5% | ||||||||||||
Switching time | Electricity disruption or electricity recovery: Zero; Switching between UPS and bypass: <1ms | ||||||||||||
Wave form | Sinewave | ||||||||||||
Wave form distortion | <2% (linear load) | ||||||||||||
Wave crest ratio | 3:1 | ||||||||||||
General features | Battery voltage | 192Vdc (single unit; 16 batteries) | 384Vdc (single unit; 32 batteries) | ||||||||||
Battery backup time | 10-15 minutes | ||||||||||||
Full load power (%) | 90% | 92% | 93% | ||||||||||
Overload | 150%: 1 minute; 125%: 10 minutes; 110%: 30 minutes | ||||||||||||
Appearance of Low Frequency Online UPS | |||||||||||||
Weight (kg) | 300 | 360 | 360 | 420 | 520 | 680 | 760 | 850 | 1050 | 1200 | 1450 | 1650 | |
Width (mm) | 530 | 650 | 650 | 850 | 1300 | ||||||||
Depth (mm) | 700 | 700 | 800 | 800 | 800 | ||||||||
Height (mm) | 1150 | 1540 | 1690 | 1690 | 1900 | ||||||||
Environmental Parameters of Low Frequency Online UPS | |||||||||||||
Ambient temperature | -5℃ - 40℃ (no condensation) | ||||||||||||
Noise (DBA) | <55 (one meter away) | <60 (one meter away) | <65 (one meter away) | <70 (one meter away) | |||||||||
Others | |||||||||||||
Safety standards | IEC 146-4,IEC 810-1 / 3 / 4,IEC 1000-4-2 / 3 / 4 | ||||||||||||
Bypass repairing | Auto bypass switch/manual bypass switch are available; zero interrupt protection | ||||||||||||
Warning system | Sound and light warning | ||||||||||||
Communications service | 24 hour auto reporting system is available; so as to timely remove UPS failures. | ||||||||||||
Communication interface | RS – 232 to RS-485 interface; in favor of Windows 95 / 98 / me / XP , Novell or Linux systems. |