Offline UPS (Uninterrupted Power Supply) WK
Applicationsof Offline UPS (Uninterrupted Power Supply):
Offline UPS WK is especially designed as the electric power supply of themonitoring equipments in various places.
Features ofOffline UPS (Uninterrupted Power Supply):
1. Modular type offline UPS:
our small size uninterrupted power supply is convenient for install andmaintenance;
2. High input voltage and low input voltage protection:
so the electric power supply product can work normally under the voltage rangeof 165-275V;
3. It can work normally even under frequency drift conditions;
4. Good load bearing ability:
this offline UPS adopted high quality power devices to enhance its load bearingability.
5. Good electromagnetic compatibility;
6. Shorter charge time and longer battery life:
our uninterrupted power supply adopted high power high frequency charger andadvanced charge method;
7. Variety of protections: protection for low voltage of batteries, overloadprotection, output short circuit protection,
anti-surge interference and lightning proof protections;
8. Unattended operation;
Parameters ofOffline UPS (Uninterrupted Power Supply):
Model | Offline UPS WK | ||||
Performance Parameters of Offline UPS | |||||
Input | Voltage | 165 - 275Vac | |||
Frequency | 50Hz±15% | ||||
Max. input current | 3A | ||||
Output | Voltage | DC5.5V | DC12V | AC24V | AC24V |
Max. output current | 5A | 5A | 5A | 5A | |
Battery | Built-in batteries | 17AH/12VDC (2 batteries) | |||
Charge duration | 12 hours (90%) | ||||
Protections | Low voltage of batteries | Alarming and auto power off; Auto power on after commercial power recovery | |||
Overload/short circuit | Stop output | ||||
Commercial power surge | Surge Absorbing | ||||
Lightning | Pressure sensitive and fuse | ||||
Switching time | ≤8ms | ||||
Working state & Warnings | Commercial power state | Under this sate when the indicator light is on | |||
Charge state | Under this sate when the indicator light is on | ||||
Inverting state | Under this sate when the indicator light is flickering | ||||
Voice warning | Alarming every 4 seconds under inverting state; long time alarming until power off while the battery is under voltage. | ||||
Others | Applicable environment | Indoor and outdoor | |||
Ambient temp. | -5oC - 50oC | ||||
Noise | <=50db | ||||
Insulating strength | EN50081-1/EN20081-2 | ||||
EMC | EN50155/EN50121.3.2 | ||||
Installation | Fixed on the ground | ||||
Net weight | 21KG | ||||
Gross weight | 22KG | ||||
Offline UPS size | 446 ×200 × 200 (L×W×H) |