Home Shape Memory Alloy Boiler Flow Switch

Shape Memory Alloy Boiler Flow Switch

Our shape memory alloy based switches are specially designed to automatically adjust the water flow according to incoming water temperature. They maintain a stable water flow even as water pressure changes. Based on specific water flow rate, these switches automatically output the corresponding signals to the controller for flow control.

Shape Memory Alloy Boiler Flow Switch


SCG-1-T84 Shape Memory Alloy Boiler Flow Switch


Operating voltage 5V-12V DC
Maximum operating current 25mA(DC 12V)/15mA(DC 5V)
Load capacity ≤15mA DC12≤10mA DC5(RPLUS=1kΩ)
Start flow ≤1.5L/min
Flow pulse characteristics f=8.1Q-3(f Frequency HZ, Q Flow L/min)
Accuracy(flow rate-pulse output) 3-17L/min±10%
Allow pressure resistance ≤1.75Mpa

* When the water temperature is 20℃, the water flow remains stable at 9 ± 0.5 L/min.
* When the water temperature is 5℃, the water flow remains stable at 6 ± 0.5 L/min.



SCG-1-T87 Shape Memory Alloy Boiler Flow Switch





Operating voltage 5V-12V DC
Maximum operating current 25mA(DC 12V)/15mA(DC 5V)
Load capacity ≤15mA DC12≤10mA DC5(RPLUS=1kΩ)
Start flow ≤1.5L/min
Flow pulse characteristics f=8.1Q-3(f Frequency HZ, Q Flow L/min)
Accuracy(flow rate-pulse output) 3-17L/min±10%
Allow pressure resistance ≤1.75Mpa

* When the water temperature is 20℃, the water flow remains stable at 9 ± 0.5 L/min.
* When the water temperature is 5℃, the water flow remains stable at 6 ± 0.5 L/min.



SCG-1-T88 Shape Memory Alloy Boiler Flow Switch





Maximum operating current 25mA(DC 12V)/15mA(DC 5V)
Load capacity ≤15mA DC12≤10mA DC5(RPLUS=1kΩ)
Start flow ≤1.5L/min
Flow pulse characteristics f=8.1Q-3(f Frequency HZ, Q Flow L/min)
Accuracy(flow rate-pulse output) 3-17L/min±10%
Allow pressure resistance ≤1.75Mpa

* When the water temperature is 20℃, the water flow remains stable at 10.5 ± 0.5 L/min.
* When the water temperature is 5℃, the water flow remains stable at 5.5 ± 0.5 L/min.



SCG-1-T93 Shape Memory Alloy Boiler Flow Switch





Operating voltage 5V-12V DC
Maximum operating current 25mA(DC 12V)/15mA(DC 5V)
Load capacity ≤15mA DC12≤10mA DC5(RPLUS=1kΩ)
Start flow ≤1.5L/min
Flow pulse characteristics f=8.1Q-3(f Frequency HZ, Q Flow L/min)
Accuracy(flow rate-pulse output) 3-17L/min±10%
Allow pressure resistance ≤1.75Mpa

* When the water temperature is 20℃, the water flow remains stable at 12.5 ± 0.5 L/min.
* When the water temperature is 5℃, the water flow remains stable at 6.5 ± 0.5 L/min.



SCG-1-T103 Shape Memory Alloy Boiler Flow Switch





Operating voltage 5V-12V DC
Maximum operating current 25mA(DC 12V)/15mA(DC 5V)
Load capacity ≤15mA DC12≤10mA DC5(RPLUS=1kΩ)
Start flow ≤1.5L/min
Flow pulse characteristics f=8.1Q-3(f Frequency HZ, Q Flow L/min)
Accuracy(flow rate-pulse output) 3-17L/min±10%
Allow pressure resistance ≤1.75Mpa ≤1.75Mpa

* When the water temperature is 20℃, the water flow remains stable at 10.5 ± 0.5 L/min.
* When the water temperature is 5℃, the water flow remains stable at 6.5 ± 0.5 L/min.



SCG-1-T107 Shape Memory Alloy Boiler Flow Switch





Operating voltage 5V-12V DC
Maximum operating current 25mA(DC 12V)/15mA(DC 5V)
Load capacity ≤15mA DC12≤10mA DC5(RPLUS=1kΩ)
Start flow ≤1.5L/min
Flow pulse characteristics f=8.1Q-3(f Frequency HZ, Q Flow L/min)
Accuracy(flow rate-pulse output) 3-17L/min±10%
Allow pressure resistance ≤1.75Mpa

* When the water temperature is 20℃, the water flow remains stable at 15 ± 0.5 L/min.
* When the water temperature is 5℃, the water flow remains stable at 11.5 ± 0.5 L/min.



SCG-1-S115 Shape Memory Alloy Boiler Flow Switch





Operating voltage 5V DC
Maximum operating current 25mA(DC 12V)/15mA(DC 5V)
Load capacity ≤15mA DC12≤10mA DC5(RPLUS=1kΩ)
Start flow ≤1.5L/min
Flow pulse characteristics f=8.1Q-3(f Frequency HZ, Q Flow L/min)
Accuracy(flow rate-pulse output) 3-17L/min±10%
Allow pressure resistance ≤1.75Mpa

* When the water temperature is 20℃, the water flow remains stable at 10.5 ± 0.5 L/min.
* When the water temperature is 5℃, the water flow remains stable at 5.5 ± 0.5 L/min.



SCG-1-S120 Shape Memory Alloy Boiler Flow Switch





Operating voltage 5V DC
Maximum operating current 15mA (DC 5V)
Load capacity ≤10mA DC5 (RPLUS=1kΩ)
Start flow ≤1.5L/min
Flow pulse characteristics f=8.1Q-3(f Frequency HZ, Q Flow L/min)
Accuracy(flow rate-pulse output) 3-17L/min±10%
Allow pressure resistance ≤1.75Mpa

* When the water temperature is 20℃, the water flow remains stable at 10.5 ± 0.5 L/min.
* When the water temperature is 5℃, the water flow remains stable at 5.5 ± 0.5 L/min.



SCG-1-S123 Shape Memory Alloy Boiler Flow Switch


Operating voltage 5V ~ 12V DC
Maximum operating current 25mA (DC 12V)/ 15mA (DC 5V)
Load capacity ≤15mA DC12 ≤10mA DC5 (RPLUS=1kΩ)
Start flow ≤1.5L/min
Flow pulse characteristics f=8.1Q-3(f Frequency HZ, Q Flow L/min)
Accuracy(flow rate-pulse output) 3-17L/min±10%
Allow pressure resistance ≤1.75Mpa

* When the water temperature is 20℃, the water flow remains stable at 10 ± 0.5 L/min.
* When the water temperature is 5℃, the water flow remains stable at 6.5 ± 0.5 L/min.



SCG-1-T118 Shape Memory Alloy Boiler Flow Switch


Operating voltage 5V ~ 12V DC
Maximum operating current 25mA (DC 12V)/ 15mA (DC 5V)
Load capacity ≤15mA DC12 ≤10mA DC5 (RPLUS=1kΩ)
Start flow ≤1.5L/min
Flow pulse characteristics f=8.1Q-3(f Frequency HZ, Q Flow L/min)
Accuracy(flow rate-pulse output) 3-17L/min±10%
Allow pressure resistance ≤1.75Mpa

* When the water temperature is 20℃, the water flow remains stable at 10 ± 0.5 L/min.
* When the water temperature is 5℃, the water flow remains stable at 6.5 ± 0.5 L/min.