The low noise condensing units are theoutstanding Refrigeration Equipment that we offered. Delivering Semi-Hermetic Bitzer compressor, they are applicable to temperature rangeof -5℃~5℃and -15℃~-25℃,
Application
Our low noise condensing units are suitable for food fresh keeping, ice makingfor supermarkets and other users.
Middle and HighTemperature Low Noise Condensing Units:
Model | Capac | Input | Fan | Pipe | ||||||
W | KW | Air m3/h | Dia | Input w | Number | Volt | Pole | Liquid | Gas | |
LC-1 | 3990 | 2.1 | 4600 | 450 | 180 | 1 | 380 | 6 | 3/8″ | 5/8″ |
LC-2 | 4820 | 2.5 | 4600 | 450 | 180 | 1 | 380 | 6 | 3/8″ | 5/8″ |
LC-3 | 5670 | 2.8 | 4600 | 450 | 180 | 1 | 380 | 6 | 1/2″ | 7/8″ |
LC-4 | 6780 | 3.2 | 4600 | 450 | 180 | 1 | 380 | 6 | 1/2″ | 7/8″ |
LC-5 | 8350 | 4.0 | 6150 | 500 | 320 | 1 | 380 | 6 | 1/2″ | 7/8″ |
LC-6 | 9640 | 4.4 | 6800 | 560 | 280 | 1 | 380 | 8 | 1/2″ | 7/8″ |
LC-7 | 11850 | 5.4 | 6800 | 560 | 280 | 1 | 380 | 8 | 1/2″ | 1-1/8″ |
LC-8 | 14480 | 6.4 | 6800 | 560 | 280 | 1 | 380 | 8 | 5/8″ | 1-1/8″ |
LC-9 | 19190 | 8.0 | 13600 | 560 | 560 | 2 | 380 | 8 | 5/8″ | 1-1/8″ |
LC-10 | 23150 | 9.7 | 13600 | 560 | 560 | 2 | 380 | 8 | 5/8″ | 1-3/8″ |
LC-11 | 27700 | 11.4 | 16400 | 610 | 760 | 2 | 380 | 8 | 7/8″ | 1-5/8″ |
LC-12 | 32300 | 13.4 | 16400 | 610 | 760 | 2 | 380 | 8 | 7/8″ | 1-5/8″ |
Remarks:
1. Test condition: -5℃/50℃.
2. Air flow is the max value at 0 static pressure.
3. Power supply: 380V/50HZ.
4. Refrigerant for all is R22.
Middle and LowTemperature Low Noise Condensing Units:
Model | Capac | Input | Fan | Pipe | ||||||
W | KW | Air m3/h | Dia | Input w | Number | Volt | Pole | Liquid | Gas | |
LC-20 | 3520 | 2.3 | 4600 | 450 | 180 | 1 | 380 | 6 | 3/8″ | 7/8″ |
LC-21 | 4450 | 2.7 | 4600 | 450 | 180 | 1 | 380 | 6 | 3/8″ | 7/8″ |
LC-22 | 4960 | 3.1 | 4600 | 450 | 180 | 1 | 380 | 6 | 1/2″ | 7/8″ |
LC-23 | 6160 | 3.8 | 4600 | 450 | 180 | 1 | 380 | 6 | 1/2″ | 1-1/8″ |
LC-24 | 7280 | 4.2 | 6800 | 560 | 280 | 1 | 380 | 8 | 1/2″ | 1-1/8″ |
LC-25 | 9650 | 5.1 | 6800 | 560 | 280 | 1 | 380 | 8 | 5/8″ | 1-1/8″ |
Lc-26 | 11880 | 6.4 | 6800 | 560 | 280 | 1 | 380 | 8 | 5/8″ | 1-3/8″ |
LC-27 | 13800 | 7.7 | 12300 | 500 | 640 | 2 | 380 | 6 | 5/8″ | 1-3/8″ |
LC-28 | 16150 | 8.4 | 13600 | 560 | 560 | 2 | 380 | 8 | 7/8″ | 1-3/8″ |
LC-29 | 21100 | 11.8 | 13600 | 560 | 560 | 2 | 380 | 8 | 7/8″ | 1-5/8″ |
LC-30 | 24450 | 13.4 | 16400 | 610 | 760 | 2 | 380 | 8 | 7/8″ | 2-1/8″ |
Remarks:
1. Test condition: -20℃/ 50℃.
2. Air flow is the max value at 0 static pressure.
3. Power supply: 380V/50HZ.
4. Refrigerant for all is R22.
5. The CIC liquid injection system is needed at the lower temperature.