Model | Max daisy chain(LED Qty) | Color | Luminous flux(Output) | Color temperature(K) | Color rendering index R(CRI) | Nominal voltage | Dimension | Power(W/M) | Luminous flux(lm/M) |
(CCT) | (V DC) | (length*width*height mm) | |||||||
GT0612-2806-120W-24 | 120-LED/M | red/green/blue/yellow/write/pure write/Warm White/ice blue/Rose red | 720-960lm/PC | 2700-6500K | ≥80% | 24 | 5000*6*12 | 12 | 1300-1500 |
GT0815-2806-120W-24 | 120-LED/M | red/green/blue/yellow/write/pure write/Warm White/ice blue/Rose red | 720-960lm/PC | 2700-6500K | ≥80% | 24 | 5000*8*15 | 12 | 1300-1500 |
GT1023-2810-120W-24 | 120-LED/M | red/green/blue/yellow/write/pure write/Warm White/ice blue/Rose red | 720-960lm/PC | 2700-6500K | ≥80% | 24 | 5000*10*23 | 12 | 1300-1500 |
Precaution: Please note that the strips are not bendable in all directions. Please follow the instructions.
Face the light surface, fold the strip, the minimum bending diameter is 40mm (as the picture shows) Light surface upwards, the strip is bendable to right or left naturally, the minimum bending diameter is 50mm (as shown) Face to the side surface, (as shown). Do not bend downward Face to the side surface, (as shown). Do not bend upward or risk damaging the stripLED strips are low voltage products, you must use the AC-DC switching power supply (transformer). Do not connect the LED strip directly to the AC110V or AC220V, otherwise, it will burn out the LED strips, which can be dangerous.
Please read the specifications thoroughly before installation by professional staff to ensure safety.
Installation Instructions: The main power cable uses 2x1.5mm2. If the LED Rigid Bar lines need to be lengthened, then the lamp power needs a wire above 0.75mm2 / 18 # specifications in order to avoid overloading the power cord leading to excessive heat. The power supply and power cord length straight between the lamp must not exceed 3 meters. If it does, line loss will increase. Please use the connection diagram in the wiring scheme The screws into the lamp mounting should feature straight holes and lock in place When LED Rigid Bar trails have a bare wire conductor, first strip off about 10mm then screw into the connection head insulation protection. To ensure waterproofing and corrosion protection of the power line after screwing Terminals, we recommend an injection with one-component silicone (or neutral glass, plastic, or with waterproof grease), covering bare copper wire power cord for protection Do not touch live wire Recommend switching power supply with the relevant regulatory certification (short circuit protection, overvoltage protection, overcurrent protection). Packaging diagram: Packaging instructions: Carton package, box size:250*350mm Carton outer size:457*337*320mm Each box contains 50 bags, total 50PCS Net Weight(NW)6.5(1±10%)kg Gross Weight(GW):8.7(1±10%)kg Note: The above package quantity and weight of packaging is only for illustration. Examples of applications: