The 3-Phase Pressure Switches are used to regulate the tank pressure between two preset values on 3 phase electrically driven air compressors. The 3-Phase pressure switches are available with an unloader valve, which prevents compressors from starting under load, and it is available with an On-Off knob for manual cut off the compressor.
Technical Data
Model | Unloader Valve | Min On (Cut-In) (Bar) | Max Off (Cut-Out) (Bar) | Differential (Bar) | Factory Setting (Bar) | Electrical Rating | Pipe Fittings | Contact Arrangement | |
Current | Voltage | ||||||||
PA01-1 | 2.0 | 8.0 | 1.0-3.0 | 3.8-5.0 | 16A | 400V | G1/4" or G1/2" Female | N.C. | |
PA01-2 | 1 | 2.0 | 8.0 | 1.2-3.5 | 3.6-5.0 | 16A | 400V | G1/4" or G1/2" Female | N.C. |
PA01-3 | 3.0 | 11.0 | 1.2-3.0 | 5.5-7.0 | 16A | 400V | G1/4" or G1/2" Female | N.C. | |
PA01-4 | 1 | 3.0 | 11.0 | 1.4-4.0 | 5.3-7.0 | 16A | 400V | G1/4" or G1/2" Female | N.C. |
PA01-5 | 4.0 | 16.0 | 1.4-4.0 | 8.0-10.0 | 16A | 400V | G1/4" or G1/2" Female | N.C. | |
PA01-6 | 1 | 4.0 | 16.0 | 2.0-4.4 | 7.8-10.0 | 16A | 400V | G1/4" or G1/2" Female | N.C. |