The air pressure switch (25-175 PSI) is used to regulate the tank pressure between two preset values on small (up to 175psi) electrically driven air compressors. The air pressure switch is available with an unloader valve, which prevents compressors from starting under load, and an auto-off disconnect lever for manual cut off the compressor. A four port manifold style is available which provides a means for easy mounting of valves and gauges.
Features
Corrosion resistant and non metallic cover
No wire looping
Visible contact
No drift pressure setting
Captive cover screw
Ample wiring room
2 ground screw
Easy to adjust
Automatic unloader valve is available
Technical Data
MODEL | Min On (Cut-In)PSI | Max Off (Cut-Out) PSI | Differential PSI | Factory Setting PSI | Electrical Rating | Pipe Fittings | Contact Arrangement | |
120VAC | 240VAC | |||||||
PA03-1 | 25 | 100 | 20-30 | 50-80 | 20A | 12A | NPT 1/4 Male or Female NPT | NC |
PA03-2 | 35 | 150 | 30-40 | 85-115 | 20A | 12A | 1/4" Male or Female NPT | NC |
PA03-3 | 50 | 175 | 35-55 | 110-150 | 20A | 12A | 1/4" Male or Female NPT | NC |
Note: 1Kgf/cm2 = 14.2PSI, 1bar = 14.5PSI
Model | Min On (Cut-In)PSI | Max Off (Cut-Out) PSI | Differential PSI | Factory Setting PSI | Electrical Rating | Pipe Fittings | Contact Arrangement | |
120VAC | 240VAC | |||||||
PA03-4 | 25 | 100 | 20-30 | 50-80 | 20A | 12A | 1/4" Female NPT (4 Port) | NC |
PA03-5 | 35 | 150 | 30-40 | 85-115 | 20A | 12A | 1/4" Female NPT (4 Port) | NC |
PA03-63 | 50 | 175 | 35-55 | 110-150 | 20A | 12A | 1/4" Female NPT (4 Port) | NC |