Home Air Cooled Chiller (Screw Water Chiller)

Air Cooled Chiller (Screw Water Chiller)

Air Cooled Chiller (Screw Water Chiller)

Air cooled chiller absorbs the heat from the processing water through the ventilation. The condenser's fans expel heat to the atmosphere from the evaporator, cooling compressor and the pipes.
Our air cooled chiller adopts imported copper pipes and automatic welding elbow, which improves the air tightness and eradicates the emission of freezing medium.

Air Cooled Chiller (Screw Water Chiller)


Our air cooled chiller adopts fins for heat dissipation punched by high-speed punch machine. Because the rims of good quality are flanged twice, fins attach to copper pipes more closely and enable the high heat exchange efficiency.
 


Technical Parameters of Fan Cooling Spiral Long Rod Freezing Unit


Single Compressor Series



  Type Parameters

PC-40 ASCS

PC-50 ASCS

PC-60 ASCS

PC-70 ASCS

PC-80 ASCS

Rated Cooling Capacity

50HZ

Btu/h

391927

498103

564334

654464

756542

Kcal/h

98710

125451

142132

164832

190542

KW

114.8

145.9

165.3

191.7

221.6

USRT

32.6

41.5

47.0

54.5

63.0

Input Power Supply

~380V/3PHASE/HZ

Input Power(KW)

35.5

44.2

45.6

52.9

60.5

Cooling Loop

1

1

1

1

1

Coolant Flow Control

Heat Expansion Value Elecitronic Expansion Valve(Optional)

Cooling Media

R22/407C/134A

Compressor

Pattern

Semi-sealed Spiral Long Rod Style

Quantity

1

1

1

1

1

Starting Method

Y-△ Starting

Capacity Control(%)

100-75-50-25

Condenser

Pattern

High Effective Red Copper Pipes Covered Into Aluminum Fins

Air flow(CMH)

50340

63690

69570

80670

93030

Enine Power(KW)

3.44

5.16

5.16

5.16

6.88

Evaporator

Pattern

High Effective Inner Grooved Copper Pole Shell and Pole condenser Made in Kobe

Quantity

1

1

1

1

1

Presure Loss(Kpa)

72

72

72

72

72

Water Flow(m3/h)

22.5

28.5

31.5

36.5

42.2

Temperature Controller

CAREL micro-computer controlled system for refrigeration

Safety Device

High/Low Voltage Switch, Exhausting Overheat Protection, Fusible Plug Anti-Freezing Temperature Controller Compressor Heat Protector, Overcurrent Relay, Phase Sequence Protector/Lack Phase Protector, Lack Pressure Protection

Pipes Connection

Freezing Water Flow In/Out(Inch)

2.5

2.5

3

3

3

Machine Weight(Kg)

925

1080

1200

1500

1680

Machine Weight(Kg)

990

1160

1300

1600

1800


 


 


Type ParametersPC-100 ASCSPC-120 ASCSPC-140 ASCSPC-160 ASCSPC-180 ASCS
Rated Cooling Capacity50HZBtu/h9303151120475133453314912351682078
Kcal/h234308282201336113375580423646
KW272.5328.2390.9436.8492.7
USRT77.593.3111.1124.2140.1
Input Power Supply~380V/3PHASE/HZ
Input Power (KW)73.188.0103.5114.6128.7
Cooling Loop11111
Coolant Flow ControlHeat Expansion Value Elecitronic Expansion Valve(Optional)
Cooling MediaR22/407C/134A
CompressorPatternSemi-sealed Spiral Long Rod Style
Quantity11111
Starting MethodY-△ Starting
Capacity Control(%)100-75-50-25
CondenserPatternHigh Effective Red Copper Pipes Covered Into Aluminum Fins
Air flow(CMH)113970137280163080181890207240
Enine Power(KW)6.888.610.3212.0413.76
EvaporatorPatternHigh Effective Inner Grooved Copper Pole Shell and Pole condenser Made in Kobe
Quantity11111
Presure Loss(Kpa)8585858585
Water Flow(m3/h)51.962.574.583.295.7
Temperature ControllerCAREL micro-computer controlled system for refrigeration
Safety DeviceHigh/Low Voltage Switch, Exhausting Overheat Protection, Fusible Plug Anti-Freezing Temperature Controller Compressor Heat Protector, Overcurrent Relay, Phase Sequence Protector/Lack Phase Protector, Lack Pressure Protection
Pipes ConnectionFreezing Water Flow In/Out(Inch)44444
Machine Weight(Kg)20002360280030003700
Machine Weight(Kg)21002600300032004000

 


Double Compreesor Series


  Type

Parameters

PC-80 ASCS

PC-100 ASCS

PC-120 ASCS

PC-160 ASCS

Rated Cooling Capacity

50HZ

Btu/h

784196

996205

1129010

1513426

Kcal/h

197506

250903

284351

381169

KW

229.7

291.8

330.7

443.3

USRT

65.3

83.0

94.0

126.0

Input Power Supply

~380V/3PHASE/HZ

Input Power (KW)

71.0

88.4

91.2

121.0

Cooling Loop

2

2

2

2

Coolant Flow Control

Heat Expansion Value Elecitronic Expansion Valve(Optional)

Cooling Media

R22/407C/134A

Compressor

Pattern

Semi-sealed Spiral Long Rod Style

Quantity

2

2

2

2

Starting Method

Y-△ Starting

Capacity Control(%)

100-75-50-25

Condenser

Pattern

High Effective Red Copper Pipes Covered Into Aluminum Fins

Air flow(CMH)

100680

127380

139140

186060

Enine Power(KW)

6.88

5.16

8.6

12.041

Evaporator

Pattern

High Effective Inner Grooved Copper Pole Shell and Pole condenser Made in Kobe

Quantity

1

1

1

1

Presure Loss(Kpa)

85

85

85

85

Water Flow(m3/h)

44.9

57.1

63.0

84.4

Temperature Controller

CAREL micro-computer controlled system for refrigeration

Safety Device

High/Low Voltage Switch, Exhausting Overheat Protection, Fusible Plug Anti-Freezing Temperature Controller Compressor Heat Protector, Overcurrent Relay, Phase Sequence Protector/Lack Phase Protector, Lack Pressure Protection

Pipes Connection

Freezing Water Flow In/Out(Inch)

4

4

4

4

Machine Weight(Kg)

1800

2000

2400

3200

Machine Weight(Kg)

2000

2200

2600

3500


 


 


Notice
Cooling output is based on the temperature conditions regulated in JIS B8613 standard
Inlet temperature of freezing water: 12℃
Outlet temperature of freezing water: 7℃
Inlet temperature of cooling water: 30℃
Outlet temperature of cooling water: 35℃


Besides the types in the form above, our company welcomes consumers to have various needs and we will produce and offer new types according to your needs. Our company reserves the right to adjust the product design and norm without notification.



 