Home CMS 30kVA UPS, Scalable to 150kVA, 400V, 40pcs Battery

CMS 30kVA UPS, Scalable to 150kVA, 400V, 40pcs Battery

CMS 30kVA UPS system uses modules with power of 30kVA and is scalable to a maximum of 150kVA power capacity. Sicon provides the following 4 standard 3 phase modular UPS systems.

CMS 30kVA UPS, Scalable to 150kVA, 400V, 40pcs Battery
CMS 60KVA UPS System Maximum power: 60kVA Power module model: CM30 Module power: 30kVA Direct voltage: ±240V Dimension: 600*800*1200mm (W*D*H), standard 19 inch cabinet Weight: 150kg
CMS 90KVA UPS System Maximum power: 90kVA Power module model: CM30 Module power: 30kVA Direct voltage: ±240V Dimension: 600*800*1200mm (W*D*H), standard 19 inch cabinet Weight: 200kg

CMS 120KVA UPS System Maximum power: 120kVA Power module model: CM30 Module power: 30kVA Direct voltage: ±240V Dimension: 600*800*1600mm (W*D*H), standard 19 inch cabinet Weight: 200kg

CMS 150KVA UPS System Maximum power: 150kVA Power module model: CM30 Module power: 30kVA Direct voltage: ±240V Dimension: 600*800*1600 mm (W*D*H), standard 19 inch cabinet Weight: 260kg

UPS System Technical Parameters Module
Module model CM30
Module power 30 kVA
Power connection 3/3 phase
Module dimension (W*D*H)mm 482*465*133
Weight(kg) Approximate 20 kg
Module charging Each module provides 7.5kVA charging power
Input power factor ≥ 0.99
Maximum heat dissipation power 1900W
THDI (%) ≤ 3%
Mains Input
Input mode 3-phase +N +E, 1-phase +N +E
Input voltage 380V/220V±20%, 400V/230V±20%, 415V/240V±20%
Input frequency 50Hz±10%, 60Hz±10%
Power woke-in (Sec.) 60sec
THDI (%) <3%
Input PF ≥0.99
Bypass Input
Input voltage 380V/220V±20%, 400V/230V±20%, 415V/240V±20%
Input frequency 50 Hz, 60 Hz
Range of Frequency Synchro 50 Hz±4%, 60 Hz±4%
DC Input
Rated Input voltage ±384VDC
Input voltage tolerance ±345V~±440V DC
Battery charging
Charging current limited yes
Charging ability 10 hours (2 hours back up)
Stability of charging voltage ±1%
AC output
UPS power factor 1
Output voltage 380V/220V AC, 400V/230V AC, 415V/240V AC
Output frequency ±4%;±0.2% (battery supply)
Output voltage stability ±1%
Output voltage recovering time <20ms (load 0~100% change)
Overload ability Operate 10mins with 125% load
Transfer from mains to battery supply 0ms
Transfer from bypass to inverter supply
Peak factor 3:01
Waveform distortion ≤1% ( linear load ), ≤3%( non-linear load )
Overall efficiency ≥95% (AC~AC), ≥98% (DC~AC)
Load share precision ≤5%
Operation environment
Ambient temperature -25℃~60℃
Operating temperature -5℃~40℃
Maximum operation altitude ≤1500m
Relative humidity ≤95% non-cadency
Protection degree IP30
Cooling Air cooling
Applicable safety standards EN62040-1-1:2003 IEC60950-1:2001
Electromagnetic compatibility EN62040-2:2006
Acoustic noise ≤55DB
Others
Cabinet Standard 19 inch cabinet
Monitor management system UPSupervisor
Interface RS232, RS485 and 8 try contact, TCP/IP adapter, SNMP(optional)
Display Touch LCD/LED Screen

Recommended Products