Developed by Xinzhou, this heat pump drying system reuses heat from the dehumidification unit, as well as heat produced by the equipment itself, thus resulting in an energy saving and faster drying performance.
As one type of low temperature drying equipment, the heat pump drying system is designed for drying agricultural products, such as shiitake mushrooms, wheat, rice, vegetables, and more. A low nutrient loss is guaranteed, as is an appealing appearance.
Tea Incense Stick Peanut Ceramics Shiitake Mushroom PaperXinzhou offers clients a series of heat pump drying systems, parameters of which are listed below. We also offer customization services.
Reference:
Ambient Temperature: 20℃
COP Value: 3.8
Parameters of XZST-03-I and XZST-O3-Ⅱ Heat Pump Drying SystemModel | Compressor Power (Kw) | Rated Heat | Fan Heater Power (KW) | Cooling Fan Power (Kw) | Circulating Air Volume (m³/h) | Noise | Dimension | Voltage/Frequency | Highest Hot Air Temperature | Ambient Temperature Range | Freezing Medium | |
External Machine for Cooling | Internal Machine for Heating | |||||||||||
XZST-03-I | 10.5KW | 2.2KW | 0.25KW | 0.25KW | 3200 m³/h | 65dB(A) | 680x360x1060 | 720x680x800mm | 380V~/3N/50HZ | High Temperature Type: 80°C Common Type: 60°C | 20-43°C | Mixing Freezing Mediums |
XZST-O3-Ⅱ | 10.5KW | 2.2KW | 1.1KW | 0.25KW | 3200 m³/h | 65dB(A) | 680x360x1060 | 720x680x800mm |
Model | Compressor Power (Kw) | Rated Heat | Fan Heater Power (KW) | Cooling Fan Power (Kw) | Circulating Air Volume (m³/h) | Noise | Dimension | Voltage/Frequency | Highest Hot Air Temperature | Ambient Temperature Range | Freezing Medium | ||
External Machine for Cooling | Internal Machine for Heating | ||||||||||||
XZST-05-I | 18KW | 3.7KW | 0.35KW | 0.35KW | 5600 m³/h | 65dB(A) | 820x820x980 mm | 840x840x850mm | 380V~/3N/50HZ | High Temperature Type: 80°C Common Type: 60°C | 20-43°C | Mixing Freezing Mediums | |
XZST-05-Ⅱ | 18KW | 3.7KW | 2.2KW | 0.35KW | 5600 m³/h | 65dB(A) | 820x820x980 mm | 840x840x850mm |
Model | Compressor Power (Kw) | Rated Heat | Fan Heater Power (KW) | Cooling Fan Power (Kw) | Circulating Air Volume (m³/h) | Noise | Dimension | Voltage/Frequency | Highest Hot Air Temperature | Ambient Temperature Range | Freezing Medium | |
External Machine for Cooling | Internal Machine for Heating | |||||||||||
XZST-10-I | 35KW | 7.5KW | 0.75KW | 4KW | 11000m³/h | 70dB(A) | 880x1280x1350mm | 1400x980x900mm | 380V~/3N/50HZ | High Temperature Type: 80°C Common Type: 60°C | 20-43°C | Mixing Freezing Mediums |
XZST-10-Ⅱ | 35KW | 7.5KW | 0.75KW | 4KW | 11000m³/h | 70dB(A) | 880x1280x1350mm | 1400x980x900mm |