DFF20-1 high power DC electrical measuring system consists of a rectification power supply (10 kw or 20kw), a 20kw generator, one or multiple (3~5) receivers, stimulators, dummy loads, AB electrodes, AB power lines, reels, measure electrodes and other accessories. DFF20-1 high power DC electrical measuring systems are widely used for metal and nonmetal mineral resource survey, high-precision mineral resource survey and the exploration of underground water resources.
Feature There are three synchronization mechanisms to ensure accuracy, including GPS, pulse delay and high accuracy quartz clock. The transmitter and rectification power supply are separated, so that the system is more portable and convenient for field work.
The system is controlled by microcomputer and equipped with a large LCD screen and a touch panel, providing convenience to operators.
Real-time storage of power supply current and sampling at every minute provide convenience for accurate calculation of apparent resistivity.
There is overvoltage, overcurrent and overheat protection.
The special small transformer is efficient and light-weighted.
Specification 1. DJS-9 DC electrical receiver Maximum measuring voltage | ±2.5V |
Voltage resolution | 0.01mV |
Measurement accuracy | ±1% (when>10mV) ±0.2mV (when 3mV~10mV) |
SP compensation range | ±1000mV |
Synchronization modes | GPS, high accuracy quartz clock, software |
Adapt power-on line | 1~60s optional |
Superposition Times | 1~10 optional |
Instrument Delay Time | 100ms ~1000ms optional |
Interference Suppression on 50Hz Power Frequency | Better than 60dB |
Instrument Input Impedance | >5 MΩ |
Power | 7.2V8.8Ah chargeable lithium battery (continuously powering for 50 hours) |
Volume | 240×95×240mm |
Weight | 1.5kg |
2. DJR waveform DC electrical receiver Measuring voltage range | ±40V (32bit A/D) |
Voltage resolution | 5nV |
Relative measure error | ≤±0.2% |
Instrument input impedance | ≥50MΩ |
Input protection voltage | 1000V |
Screen | 5-inch 24bit true-color LCD |
Storage capacity | 8G-64G |
Waterproof level | IP67 |
Working temptation | -20-+60℃ |
Volume | 240 mm×95 mm×240mm |
Weight | 1.5kg |
3. DKG rectification power supply Specification | 5A/2000V | 10A/2000V |
AC voltage | Single-phrase 220V | Three-phrase 380V |
Power frequency | 50HZ | 50HZ |
Output voltage | 2000VDC | 2000VDC |
Output current | 5A | 10A |
Weight | 50KG | 83KG |
Volume (mm) | 560*320*500 | 800*400*600 |
Maximum output power | 10KW | 20KW |
4. DJF20-1 20KW transmitter Output voltage range | 0--2000V |
Output current | 0.1A-10A |
Battery | Built-in 12V lithium battery or out-connected 12V battery |
Weight | 35kg |
Volume | 560mm×320mm×500mm |