Introduction
The fresh air ventilation duct air conditioner uses direct evaporation of the refrigerant to adjust the temperature of the outdoor air and bring it closer to that of the indoor air. With a balanced and easy air supply design, the indoor air quality is significantly improved through a more simplified design. The unit's energy efficiency has also been improved due to a special condensing heat recovery technology that solves frosting issues prevalent in cold weather. The unit can be operated 24/7, and achieve an air purification, humidification, dehumidification and oxygen increase in order to satisfy various customer requirements.
Model Project | WMV200L | WMV300L | WMV400L | WMV500L | WMV600L | WMV800L | WMV1000L | ||
System | Indoor unit | ||||||||
Unit characteristics | Refrigerating capacity | kW | 15.3 | 19.0 | 25.3 | 31.8 | 39.5 | 52.0 | 65.0 |
Heating capacity | kW | 8.5 | 9.1 | 14.5 | 18.0 | 22.8 | 29.8 | 41.5 | |
Noise | dB | 52 | 56 | 64 | 65 | 66 | 68 | 69 | |
Humidification | Type | Electrode humidification / Wet film humidification / Steam humidification | |||||||
Refrigerant control | Thermal expansion valve /Electronic expansion valve | ||||||||
Air filter | Special air filter | ||||||||
Air supply system | Fresh air volume | m³/h | 1500 | 3000 | 4000 | 5000 | 6000 | 8000 | 10000 |
Outside residual pressure of blower | Pa | 120 | 180 | 190 | 220 | 250 | 300 | 350 | |
Motor power | kW | 0.45 | 0.8 | 0.8×2 | 1.5×2 | 1.8×2 | 2.2×2 | 3.0×2 | |
Exhaust system | Exhaust air volume | m³/h | 〉1.0~1.03 Blower air flow | ||||||
Outside residual pressure of exhaust fan | Pa | 120 | 150 | 150 | 150 | 300 | 300 | 350 | |
Motor power | kW | 0.45 | 0.8 | 0.8×2 | 1.5×2 | 1.8×2 | 2.2×2 | 3.0×2 | |
Heat recovery | Type | Total heat recovery unit | |||||||
Heat exchange rate | 50%~75% | ||||||||
Outline size | Length | mm | 1450 | 1450 | 1850 | 2550 | 2550 | 1850 | 2550 |
Width | mm | 890 | 890 | 990 | 900 | 900 | 1750 | 1750 | |
High | mm | 1680 | 1680 | 1680 | 1680 | 1680 | 2555 | 2635 | |
System | Outdoor unit | ||||||||
Unit characteristics | Power Supply | 380V/3N/50Hz | |||||||
Compressor Type | Totally enclosed scroll type / Variable frequency compressor | ||||||||
Compressor quantity | 1 | 1 | 1 | 1 | 1 | 1 | 2 | ||
Input power | kW | 4.82 | 6.8 | 7.2 | 10.8 | 11.5 | 15.8 | 17.8 | |
Weight | kg | 80 | 150 | 175 | 220 | 230 | 270 | 350 | |
Outline size | Length | mm | 995 | 995 | 1170 | 1440 | 1440 | 1808 | 1808 |
Width | mm | 400 | 400 | 690 | 800 | 800 | 980 | 980 | |
High | mm | 935 | 935 | 965 | 965 | 965 | 1220 | 1220 |
Feature
● Cold range: 10kW-156kW
● Air volume range: 700-15600m³/h
● Static pressure of outer plane: 50-400Pa
● Ambient working temperature: -15℃-55℃
● The unit has a wide application range, particularly in places with high noise emissions and inconvenient installation areas where a rooftop unit is the most suitable.
1. The fresh air ventilation duct air conditioner uses a ventilation mode to detect the temperature of outdoor fresh air in determining if it will operate or remain off, thus saving significant amounts of energy.
2. The unit's piping is as long as 120 meters and vertically 40 meters (the outside machine is on the top), which ensures the unit is reliable under various conditions to ensure the efficiency.
3. The long distance air supply can meet the demands of long distance air supply needs, the installation position of the unit is more flexible, and the ability to adapt to the scene is stronger.
4. The variable frequency compressor can be customized according to customer requirements.
5. The unit uses a combined control system of electronic expansion valve and thermal expansion valve, which make the unit is more reliable under the temperatures of -15℃ -55℃ and the rate of energy efficiency can reach 5.5.
6 The unit can be continuously operate under the temperatures of 35-55℃ during the summer season.
7. An air enthalpy difference controller can automatically control the fresh air between 0%—100%.
8. The unit has multi-protection functions, including fault protection, lack of reverse protection, overload and overheating protection, high temperature, high and low pressure protection, and more.
9. The unit carries a programmable controller to achieve self-diagnosis.
10. The unit carries control interface and protocol to achieve remote monitoring.
11. The unit can work without any auxiliary heating above -10°C and the low temperature unit can stably operate above -25°C.