This on-grid inverter is perfect for distributed solar systems. It is easy to install, and also offers protection from lightning with an IP65 rating for added safety. Whether you opt for single-phase or three-phase power, this inverter provides dependable performance and peace of mind.
Features0.7-3kW single phase on-grid solar inverter
Model | KY-1GT-OK7 | KY-1GT-1KO | KY-1GT-1K5 | KY-1GT-2KO | KY-1GT-2K5 | KY-1GT-3KO | |||||
Efficiency | MPPT efficiency | 99.50% | 99.50% | 99.50% | 99.50% | 99.50% | 99.50% | ||||
Max. efficiency | 95% | 96% | 96.50% | 96.50% | 96.50% | 96.50% | |||||
Euro efficiency | 94.00% | 95% | 95.50% | 95.80% | 96.00% | 96.00% | |||||
PV Input | Max. PV voltage | 500V | 500V | 500V | 500V | 500V | 500V | ||||
MPPT voltage range | 80V-450v | 80V-450V | 80V-450V | 80V-450V | 80V-450V | 80V-450V | |||||
Max. input power | 1000W | 1500W | 2000W | 2500W | 3000W | 3500W | |||||
Start voltage | 80V | 80V | 80V | 80V | 80V | 80V | |||||
Min. grid voltage | 110V | 110V | 110V | 110V | 110V | 110V | |||||
Rated input voltage | 360V | 360V | 360V | 360V | 360V | 360V | |||||
Number of MPPT/PV strings | 1/1 | 1/1 | 1/1 | 1/1 | 1/1 | 1/1 | |||||
MPPT max. current | 12.5A | 12.5A | 12.5A | 12.5A | 12.5A | 12.5A | |||||
Short circuit current | 15A | 15A | 15A | 15A | 15A | 15A | |||||
AC Output | Max. AC power | 700VA | 1000VA | 1500VA | 2000VA | 2500VA | 3000VA | ||||
Rated AC power | 700W | 1000W | 1500W | 2000W | 2500W | 3000W | |||||
Rated grid voltage/voltage range | 230V, 1(LN/PE)/160-280V | ||||||||||
Frequency | 50Hz/60Hz | ||||||||||
Max. current | 4A | 5A | 6.5A | 9.5A | 12A | 14.5A | |||||
Power factor | ~1 (0.8leading ~ 0.8lagging, adjustable) | ||||||||||
THD (@ rated output) | < 3% | ||||||||||
AC connection | Quick fit | ||||||||||
Basic parameters | Operating temperature | -25-60℃ (derating above 45℃) | |||||||||
Relative humidity | 0-95% no condensation | ||||||||||
Operating altitude | < 4000m (derating to operate at a height exceeding 2000m) | ||||||||||
Cooling | Natural cooling | ||||||||||
Noise | < 40dB | ||||||||||
Display | LCD | ||||||||||
Communication | RS485 (WIFI/GPRS optional) | ||||||||||
Weight | 6kg | 6kg | 6kg | 6.5kg | 6.5kg | 6.5kg | |||||
Dimensions | 252mm×300mm×116mm | ||||||||||
Installation | Wall mount | ||||||||||
Protection | IP65 | ||||||||||
Topology | Transformerless | ||||||||||
Certification | Safety | IEC62109-1/-2 | |||||||||
EMC | EN61000-1/-2/-3, IEC61000 | ||||||||||
Grid connection | AS4777.2, NRSO97-2-1:2017 |
10-20kW three phase on-grid solar inverter
Model | KY-3GT-10k0 | KY-3GT-12k0 | KY-3GT-15k0 | KY-3GT-17kO | KY-3GT-20kO | |||||
Efficiency | Max. efficiency | 97.80% | 98.20% | 98.30% | 98.43% | 98.50% | ||||
Euro efficiency | 98.20% | 97.80% | 97.90% | 98% | 98.10% | |||||
MPPT efficiency | 99.90% | 99.90% | 99.90% | 99.90% | 99.90% | |||||
DC Side | Max. input strings power (W) | 13000 | 15600 | 19500 | 22100 | 26000 | ||||
Rated input power | 10300 | 12350 | 15400 | 17500 | 20520 | |||||
Max. input voltage (V) | 1000 | 1000 | 1000 | 1000 | 1000 | |||||
Start voltage (V) | 180 | 180 | 180 | 180 | 180 | |||||
MPPT voltage range (V) | 200- 950 | 200 - 950 | 200- 950 | 200 - 950 | 200- 950 | |||||
Number of input strings (pcs) | 1 1 | 1 1 | 2 1 | 2 2 | 2 2 | |||||
Max. input current (A) | 12/12 | 12/12 | 23/12 | 23/23 | 23/23 | |||||
Max. DC short-circuit current (A) | 15/15 | 15/15 | 28/15 | 28/28 | 28/28 | |||||
AC Side | Rated output power (W) | 10000 | 12000 | 15000 | 17000 | 20000 | ||||
Max. output power (VA) | 10000 | 12000 | 15000 | 17000 | 20000 | |||||
Rated grid voltage/voltage range | 400V(230V)/270V-480V | |||||||||
Grid type | 3L/N/PE | |||||||||
Frequency (Hz) | 50Hz/60Hz 45Hz-55Hz/55Hz-65Hz | |||||||||
Total harmonic distortion (THD) of output current | < 1.5% | |||||||||
DC component | < 0.5%*In | |||||||||
Power factor/range | >0.99/0.8leading - 0.8lagging (adjustable) | |||||||||
Protection | DC switch | Integrate (optional) | ||||||||
Overcurrent protection/ anti-islanding protection | Integrate | |||||||||
Surge protection | DC Class Ⅱ / AC Class Ⅲ | |||||||||
DC reverse polarity protection/overvoltage & undervoltage protection | Integrate | |||||||||
Leakage current protection/insulation protection | Integrate | |||||||||
Basic parameters | Dimensions (W×D×H) (mm) | 505×200×414 | ||||||||
Weight | 16Kg | 16Kg | 17Kg | 18Kg | 18Kg | |||||
Protection | IP65 | |||||||||
Installation/cooling | Wall mount/natural convection | Wall mount/natural convection | Wall mount/forced air | Wall mount/forced air | Wall mount/forced air | |||||
Topology | Transformerless | |||||||||
No load loss | < 0.5W | |||||||||
Operating temperature | -30℃-60℃ (derating above 45℃) | |||||||||
Relative humidity | 0-95% | |||||||||
Operating altitude | < 3500m (derating to operate at a height exceeding 2000m) | |||||||||
Display | LCD | |||||||||
Communication | RS485/WIFI | |||||||||
AC/DC connection | Quick fit | |||||||||
Warranty | 5/10 years | |||||||||
Certification | Safety | IEC62109-1/-2 | ||||||||
EMC | EN61000-6-1/-2/-3,EC61000-2-2 | |||||||||
Grid connection | ASNZS 4777.2, NRS 097-2-1:2017, NBT32004-2018 |