The XGN-40.5 gas insulated metal enclosed switchgear is used for receiving and distributing electric power in AC three-phase single-busbar systems with the rated voltage of 40.5kV and the frequency of 50Hz. It can also carry out control, protection, measurement, monitoring and communication when the power system operates normally or malfunctions.
This indoor switchgear is mainly used in the power systems of substations, power plants, industrial and mining enterprises, subway, light railway, plateau railway, etc. As it is maintenance-free or low-maintenance, this gas insulated metal enclosed switchgear is particularly suitable for places with harsh running conditions, high humidity, and serious filth.
Item | Unit | Value | ||
Rated Current | A | 630, 1250, 1600, 2000 | ||
Rated Voltage | kV | 40.5 | ||
Rated Frequency | Hz | 50 | ||
Rated Peak Withstand Current (Peak Value) | kA | 80 | ||
Rated Short-circuit Closing Current (Peak Value) | ||||
Rated Short-circuit Breaking Current (Valid Value) | kA | 31.5 | ||
Rated Short-time Withstand Current (Valid Value) | ||||
Rated Short Circuit Duration | s | 4 | ||
Rated Insulation Level | Rated Lightning ImpulseWithstand Voltage (Peak) | Phase to ground,phase to phase | kV | 185 |
Isolating Break | 215 | |||
1min Power Frequency Withstand Voltage(Valid Value) | Phase to ground,phase to phase | 95 | ||
Isolating Break | 118 | |||
Auxiliary Control Loop | Rated Voltage | V | DC: 110, 220 | |
AC: 110, 220 | ||||
1min Power Frequency Withstand Voltage | 2000 | |||
Rated Pressure of the SF6 Gas at 20℃ | MPa | 0.04 | ||
Max. Pressure of the SF6 Gas at 20 ℃ | MPa | 0.06 | ||
Alarm Pressure of the SF6 Gas at 20 ℃ | MPa | 0.02 | ||
Annual Gas Leakage Rate | ≤0.5% | |||
Mechanical Life of the Isolation Switch | Times | 2000 | ||
Mechanical Life of the Earthing Switch | Times | 2000 | ||
Dimensions (W×D×H) | mm | 600×1400×1880 | ||
Protection Class | Cabinet Body: IP4X | |||
Gas Chamber: IP65 |
Service Environment
1. This gas insulated metal enclosed switchgear should be used in indoor places where there is no fire or explosion hazard, chemical corrosion or severe shaking.
2. The ambient temperature should be within the range of -25℃ to 40℃.
3. The altitude should not exceed 3,000 meters.
4. The daily average relative humidity should be lower than 95% and the monthly value should not be larger than 90%.
5. Amplitude of the electromagnetic interference induced in the secondary system should not exceed 1.6 kV.
6. The earthquake intensity should not exceed 8 degree.
Note: When the gas insulated metal enclosed switchgear needs to work in environment with the conditions failing to meet the above ones, customers should consult with us.