DrainagePipe Defrost Heater Wire / Cable
Drainage pipe defrost heater wire is an idealchoice for defrosting air cooler and preventing drain pipe from freezing incold storage. Due to the totally waterproof design, it can be installed insidethe drain pipe directly to heat the pipe and eject water smoothly, preventingthe defrosting water from freezing and blocking the pipe. Meanwhile, theproduct adopts two layers of insulators, so it is very safe to use. With themould pressing knot, this drainage pipe defrost heater wire is extremelyflexible. In addition, its working temperature range is from -60ºC to 200ºC byusing silicon rubber insulator.
Technical Specifications
Heating Element | Ni-Cr or Cu-Ni Alloy | Length/M | 40W/M | 50W/M | ||
Tail End of Heating Element | Seal Tail End of Colloidal Silica | 1 | 40W | 50W | ||
Maximum Surface Temperature | 200ºC | 1.3 | 52W | 65W | ||
Minimum Surface Temperature | -60ºC | 1.5 | 60W | 75W | ||
Immergence Withstand Voltage | AC2500V /min | 2 | 80W | 100W | ||
Voltage | 220-230V | Shape | Average7×5mm | 3 | 120W | 150W |
Power | ±5﹪ | Output Power | 40-50W/M | 4 | 160W | 200W |
Tape Length | ±5mm | Insulation Resistance | ≥200MN | 5 | 200W | 250W |
Tolerance | ±10﹪ | Leaking Current | ≤0.2MA | 6 | 240W | 300W |
Note: Ingeneral, 50W/M drainage pipe heating tape is commonly used. For plasticdrainage pipe, we recommend water pipe heating tape with 40W/M output power.