Concealed fan coil units are widely used in hotels, restaurants, factories, hospitals, malls and more. Materials used include a steel plate.
Download Video Technical ParametersConcealed fan coil units
Type | 2Pipes 2rows | ||||||
Model | RFP-34 | RFP-51 | RFP-68 | RFP-85 | RFP-102 | RFP-136 | |
Air Flow (m³/h) | H | 340 | 530 | 700 | 860 | 1020 | 1400 |
M | 270 | 420 | 560 | 700 | 810 | 1140 | |
L | 200 | 310 | 420 | 520 | 610 | 850 | |
Cooling capacity(W) | H | 1770 | 2670 | 3530 | 4450 | 5300 | 7060 |
Heating capacity(W) | H | 2700 | 4050 | 5400 | 6750 | 8100 | 10800 |
Input Power(W) | 12Pa | 32 | 46 | 56 | 75 | 94 | 134 |
30Pa | 40 | 54 | 72 | 87 | 102 | 155 | |
50Pa | 46 | 65 | 84 | 98 | 112 | 174 | |
Noise dB(A) | 12Pa | 37 | 39 | 41 | 43 | 46 | 46 |
30Pa | 40 | 42 | 44 | 46 | 47 | 48 | |
50Pa | 42 | 44 | 46 | 47 | 49 | 50 | |
Water Flow | m³/h | 0.31 | 0.47 | 0.62 | 0.78 | 0.93 | 1.23 |
Water P.D. | kPa | 30 | 30 | 30 | 40 | 40 | 40 |
Fan Type | Forward multi-wing centrifugal double suction fan | ||||||
Motor Type | Capacitor running asynchronous motor | ||||||
Coil | Rows | 2 | |||||
Pressure | Design pressure 1.6MPa,test pressure 2.5MPa | ||||||
Pipe size | Water Pipe | R3/4(internal thread) | |||||
Drain Pipe | R3/4(internal thread) | ||||||
Net weight | (kg) | 12.7 | 14.2 | 16.1 | 17.4 | 18.5 | 25.8 |
Optional accessories | Thermostat,2-way/3-way valve,return box |
Concealed fan coil units
Type | 4pipes 3 1 rows | |||||||||
Model | RFP-34 | RFP-51 | RFP-68 | RFP-85 | RFP-102 | RFP-136 | RFP-170 | RFP-204 | RFP-238 | |
Air Flow (m³/h) | H | 340 | 510 | 680 | 850 | 1020 | 1360 | 1700 | 2040 | 2380 |
M | 265 | 405 | 535 | 680 | 790 | 1060 | 1360 | 1595 | 1904 | |
L | 195 | 305 | 405 | 510 | 585 | 790 | 1020 | 1180 | 1428 | |
Cooling capacity (W) | H | 1890 | 2830 | 3780 | 4680 | 5610 | 7350 | 9000 | 10800 | 12600 |
Heating capacity (W) | H | 1480 | 2220 | 2960 | 3720 | 4150 | 5180 | 6700 | 7290 | 8500 |
Input Power (W) | 12Pa | 37 | 52 | 62 | 76 | 96 | 134 | 152 | 189 | 228 |
30Pa | 44 | 59 | 72 | 87 | 108 | 156 | 174 | 212 | 253 | |
50Pa | 49 | 66 | 84 | 100 | 118 | 174 | 210 | 250 | 300 | |
Noise dB (A) | 12Pa | 37 | 39 | 41 | 43 | 46 | 46 | 48 | 50 | 52 |
30Pa | 40 | 42 | 44 | 46 | 47 | 48 | 50 | 52 | 54 | |
50Pa | 42 | 44 | 46 | 47 | 49 | 50 | 52 | 54 | 56 | |
Water Flow | Cooling | 0.33 | 0.5 | 0.67 | 0.8 | 0.96 | 1.26 | 1.55 | 1.86 | 2.18 |
Heating | 0.13 | 0.19 | 0.25 | 0.32 | 0.37 | 0.45 | 0.58 | 0.63 | 0.73 | |
Water P.D. | kPa | 30 | 30 | 30 | 30 | 40 | 40 | 40 | 40 | 50 |
Fan Type | Forward multi-wing centrifugal double suction fan | |||||||||
Motor Type | Capacitor running asynchronous motor | |||||||||
Coil | Rows | 3 1 | ||||||||
Pressure | Design pressure 1.6MPa,test pressure 2.5MPa | |||||||||
Pipe size | Water Pipe | R3/4(internal thread) | ||||||||
Drain Pipe | R3/4(internal thread) | |||||||||
Net weight | (kg) | 15.4 | 17.2 | 19.1 | 20.5 | 22 | 29.7 | 31.5 | 35.6 | 41.5 |
Optional accessories | Thermostat,2-way/3-way valve,return box |
Notes
The data in the above tables are all for high range air flow cases with respective excessive pressures.