The air cooled screw chiller and heat pump is used for heating and cooling applications in large commercial structures such as malls, office buildings, workshops, hotels, and hospitals. The air cooling unit is especially preferred in locations in which water is scarce.
Download Technical Parameters R134a Air Cooled Screw Chiller and Heat PumpType | Screw Type | ||||||||
Model -RLSFC/RLSFCR | 260 | 280 | 320 | 360 | 460 | 500 | 560 | ||
Nominal cooling capacity | kW | 252 | 280 | 321 | 356 | 458 | 496 | 562 | |
Cooling input power | kW | 82 | 90 | 108 | 122 | 148 | 163 | 182 | |
Running current | A | 162 | 179 | 214 | 234 | 290 | 323 | 360 | |
Nominal heating capacity | kW | 246 | 280 | 328 | 368 | 465 | 503 | 583 | |
Heating input power | kW | 80 | 89 | 92 | 120 | 145 | 160 | 179 | |
Running current | A | 147 | 162 | 194 | 211 | 263 | 293 | 354 | |
Max. running current | A | 199 | 222 | 265 | 290 | 361 | 398 | 452 | |
Cable diameter (copper wire distance ≤20 meters) | mm2 | 3*95 2*50 | 3*120 2*50 | 3*150 2*70 | 3*150 2*70 | 3*185 2*95 | 3*240 2*120 | 3*240 2*120 | |
Compressor | Type | Semi-hermetic screw | |||||||
Quantity | 1 | ||||||||
Energy steps | 25%-50%-75%-100% | ||||||||
Power voltage | 3N-380V-50HZ | ||||||||
Starting mode | Y-▲ or by winding | ||||||||
Refrigerant | Type | R134a | |||||||
Charge (kg) | 70 | 80 | 95 | 110 | 135 | 150 | 170 | ||
Control | Electronic expansion valve (EXV) | ||||||||
Condenser type | Type | Internally threaded copper tube & hydrophilic aluminum fins | |||||||
Fan type | kPa | Axial type fan | |||||||
Qty | 6 | 6 | 8 | 10 | 10 | 10 | 10 | ||
Input power | kW | 2.2*6 | 2.2*6 | 2.2*8 | 2.2*10 | 2.2*10 | 2.2*12 | 2.2*12 | |
Evaporator | Type | Shell & tube type | |||||||
Water pressure drop | kPa | 70 | |||||||
Water pipe Dia. DN | 100 | 100 | 100 | 125 | 125 | 125 | 150 | ||
Water flow | m3/h | 43 | 48 | 55 | 61 | 79 | 85 | 97 | |
Heat recovery device | Type | Shell & tube type | |||||||
Qty | 30% | ||||||||
Water Pressure drop | 70 | ||||||||
Water pipe Dia. DN | 65 | 65 | 80 | 80 | 80 | 80 | 100 | ||
Water flow | m3/h | 17 | 19 | 22 | 25 | 31 | 34 | 38 | |
Heat recovery device | Type | Shell & tube type | |||||||
Qty | 100% | ||||||||
Water pressure drop | 70 | ||||||||
Water pipe Dia. DN | 80 | 100 | 100 | 100 | 125 | 125 | 125 | ||
Water flow | m3/h | 34 | 38 | 44 | 49 | 63 | 68 | 77 | |
Noise level | dB(A) | 79 | 79 | 79 | 79 | 81 | 83 | 83 | |
Dimension | L | mm | 3190 | 3190 | 4100 | 5010 | 5010 | 6168 | 6168 |
W | mm | 2250 | 2250 | 2250 | 2250 | 2250 | 2250 | 2250 | |
H | mm | 2480 | 2480 | 2480 | 2480 | 2480 | 2480 | 2480 | |
Net weight | kg | 2500 | 3000 | 3500 | 5800 | 6000 | 6200 | 6400 | |
Operation weight | kg | 3100 | 3500 | 4000 | 6200 | 6600 | 7000 | 7400 | |
Main protection measures | 1. High &low voltage protection; 2. Anti-freezing protection; | ||||||||
3. Temperature control; 4. Owe anti-phase protection; | |||||||||
5. High & low pressure protection; 6. High pressure exhaust temperature protection; | |||||||||
7. Built-in motor overheating protection; 8. Over-current protection; | |||||||||
9. Safety valve; 10.Check valve; | |||||||||
Remarks: | 1. Cooling standard working conditions Ambient temperature: 35℃DB/24℃WB Cold water inlet temperature: 12℃ Outlet temperature: 7℃ | ||||||||
2. Heating standard working conditions Ambient temperature 7℃DB/6℃WB Cold water inlet temperature 40℃ Outlet temperature 45℃ |
Type | Screw Type | ||||||||
Model -RLSFC/RLSFCR | 520 | 560 | 640 | 720 | 920 | 1000 | 1120 | ||
Nominal cooling capacity | kW | 504 | 560 | 642 | 712 | 916 | 992 | 1124 | |
Cooling input power | kW | 163 | 181 | 215 | 245 | 295 | 325 | 364 | |
Running current | A | 324 | 358 | 428 | 467 | 579 | 646 | 720 | |
Nominal Heating capacity | kW | 492 | 560 | 656 | 736 | 930 | 1006 | 1166 | |
Heating input power | kW | 160 | 177 | 185 | 240 | 290 | 320 | 357 | |
Running current | A | 293 | 323 | 387 | 422 | 526 | 586 | 708 | |
Max. running current | A | 399 | 445 | 530 | 579 | 723 | 796 | 904 | |
Cable diameter (copper wire distance ≤20 meters) | mm2 | 2*(3*95 2*50) | 2*(3*120 2*50) | 2*(3*150 2*70) | 2*(3*150 2*70) | 2*(3*185 2*95) | 2*(3*240 2*120) | 2*(3*240 2*120) | |
Compressor | Type | Semi-hermetic screw | |||||||
Quantity | 2 | ||||||||
Energy steps | 25%-50%-75%-100% | ||||||||
Power voltage | 3N-380V-50HZ | ||||||||
Starting mode | Y-▲ or by winding | ||||||||
Refrigerant | Type | R134a | |||||||
Charge (kg) | 140 | 160 | 190 | 220 | 270 | 300 | 340 | ||
Control | Electronic expansion valve (EXV) | ||||||||
Condenser type | Type | Internally threaded copper tube & hydrophilic aluminum fins | |||||||
Fan type | kPa | Axial type fan | |||||||
Qty | 12 | 12 | 16 | 20 | 20 | 24 | 24 | ||
Input power | kW | 2.2*12 | 2.2*12 | 2.2*16 | 2.2*20 | 2.2*20 | 2.2*24 | 2.2*24 | |
Evaporator | Type | Shell & tube type | |||||||
Water pressure drop | kPa | 70 | |||||||
Water pipe Dia.DN | 125 | 150 | 150 | 150 | 150 | 150 | 200 | ||
Water flow | m3/h | 87 | 96 | 110 | 122 | 158 | 171 | 193 | |
Heat recovery device | Type | Shell & tube type | |||||||
Qty | 30% | ||||||||
Water pressure drop | 70 | ||||||||
Water pipe Dia. DN | 80 | 80 | 100 | 100 | 100 | 125 | 125 | ||
Water flow | m3/h | 34 | 38 | 44 | 49 | 63 | 68 | 77 | |
Heat recovery device | Type | Shell & tube type | |||||||
Qty | 100% | ||||||||
Water pressure drop | 70 | ||||||||
Water pipe Dia. DN | 100 | 100 | 100 | 100 | 125 | 125 | 125 | ||
Water flow | m3/h | 69 | 76 | 88 | 99 | 125 | 136 | 154 | |
Noise level | dB(A) | 79 | 79 | 81 | 83 | 83 | 84 | 84 | |
Dimension | L | mm | 6186 | 6186 | 8006 | 9826 | 9826 | 12372 | 12372 |
W | mm | 2250 | 2250 | 2250 | 2250 | 2250 | 2250 | 2250 | |
H | mm | 2480 | 2480 | 2480 | 2480 | 2480 | 2480 | 2480 | |
Net weight | kg | 5400 | 6000 | 6600 | 11500 | 12500 | 13500 | 14500 | |
Operation weight | kg | 6000 | 6600 | 7200 | 12100 | 13100 | 14300 | 14400 | |
Main protection measures | 1. High & low voltage protection; 2. Anti-freezing protection; | ||||||||
3. Temperature control; 4. Owe anti-phase protection; | |||||||||
5. High & low pressure protection; 6. High pressure exhaust temperature protection; | |||||||||
7. Built-in motor overheating protection; 8. Over-current protection; | |||||||||
9. Safety valve; 10. Check valve; | |||||||||
Remarks: | 1. Cooling standard working conditions Ambient temperature: 35℃DB/24℃WB Cold water inlet temperature: 12℃ Outlet temperature: 7℃ | ||||||||
2. Heating standard working conditions Ambient temperature: 7℃DB/6℃WB Cold water inlet temperature: 40℃ Outlet temperature: 45℃ |
The chiller and pump features a modular design. Each module has the same dimensions except for length. By combining different modules, various cooling and heating demands can be met. Each module is connected through a sophisticated communication system that is controlled by a micro-computer for maximum efficiency.