We insert a single-mode or multi-mode into a loose tube made of high modulus polyester material and filled with water proof compounds. The external of loose tube is vertical wrapped double chromium-plated plastic steel tape. Water blocking material is added between the steel belt and loose tube to ensure the compact and vertical water blocking of the cable. We extrude a polyethylene sheath into the cable by placing steel plastic composite tape.
Application of Central Tube Steel Wire Armored CableThe central tube steel wire armored cable(GYXTS) is suitable for Long distance and interoffice communication.
Parameter 1. Characteristic of optical fiberG.652.D | G.655 | 50/125μm | 62.5/125μm | ||
Attenuation | @850nm | - | - | ≤3.0dB/km | ≤3.0dB/km |
@1300nm | - | - | ≤1.0dB/km | ≤1.0dB/km | |
@1310nm | ≤0.36dB/km | ≤0.36dB/km | - | - | |
@1550nm | ≤0.22dB/km | ≤0.23dB/km | - | - | |
Band width | @850nm | - | - | ≥500MHz·km | ≥200MHz·km |
@1300nm | - | - | ≥1000MHz·km | ≥600MHz·km | |
Fiber cutoff wavelength | ≤1260nm | ≤1260nm | - | - | |
Polarization Mode Dispersion | Single optical fiber | ≤0.20ps/√km | ≤0.20ps/√km | - | - |
Link value(M=20,Q=0.01%) | ≤0.10ps/√km | ≤0.10ps/√km | - | - |
Item | Content | Value | ||||
Number of cable cores | 6 | 12 | 24 | 36 | 48 | |
Loose tube | Outer diameter | 2.6 | 2.8 | 2.8 | 3.2 | 3.6 |
Number of Loose Tube* number of cores per tube | 1*6 | 1*12 | 1*24 | 1*36 | 1*48 | |
Reference outer diameter | mm | 9.5 | 9.5 | 9.5 | 10.0 | 10.5 |
Center strength member | Material | Steel wire | ||||
Diameter(mm) | 1.0 | |||||
Water blocking material | Material | Water blocking cable gel | ||||
Armored layer | Material | Corrugated steel belt | ||||
Outer sheath | Thickness(±0.2mm) | 1.8 | ||||
Range of operating temperature | ℃ | -40- +70 | ||||
Pull | Short-term /long-term(N) | 3000/1000 | ||||
Flatten | 3000/1000 | |||||
*According to customer's requirements, the stranded loose tube armored cable can customize other structures or cores. |
Item | Inspection standard | Specified value | Requirements |
Pull | IEC 60794-1-2-E1 | According to technical parameter | Additional attenuation for short term:≤0.1dB |
Flatten | IEC 60794-1-2-E3 | According to technical parameter | Additional attenuation for short term:≤0.1dB |
Impact | IEC 60794-1-2-E4 | The height is 1 meter punch hammer 450g at least 50 times | Residual additional attenuation:≤0.03dB |
Backward and forward bending | IEC 60794-1-2-E6 | Loading 150N 30 times | Residual additional attenuation:≤0.03dB |
Twisting | IEC 60794-1-2-E7 | 1 meter ±180° 10 times | Residual additional attenuation:≤0.03dB |
Temperature recycle test | IEC 60794-1-2-F1 | -40℃ +70℃ | Change of additional attenuation:≤0.05dB/km |
* The monitoring of all optical fiber attenuation's change is operated in wavelength of 1550nm. |
YD/T 769-2010 central tube outdoor cable for telecommunication
InstallationDuct, Aerial, Direct burial