The cable features an insert of single-mode or multi-mode into loose tube made of high modulus polyester material and filled with water proof compounds. The center of cable core is a metallic strength core. For the cables with a certain number of cores, the metallic strength core sheathed with polyethylene (PE). The loose tube (and filling rope) is twisted around the central strength core to form a compact circular core, whose cracks are filled with water blocking materials. Extruded polyethylene sheath is inserted into cable after the double chromium-plated plastic steel tape is vertically wrapped. Finally, an extruded polyethylene sheath into cable after armored of single steel wire.
The stranded loose tube single steel wire armored cable is suitable for Long distance and interoffice communication.
Parameter 1. Technical parameterItem | Content | Value | ||||||
Number of cable cores | 24 | 36 | 48 | 72 | 96 | 120 | 144 | |
Loose tube | Outer diameter | 1.8 | 2.5 | 2.5 | 2.5 | 2.5 | 2.5 | 2.5 |
Number of Loose Tube* number of cores per tube | 4*6 | 6*6 | 4*12 | 6*12 | 8*12 | 10*12 | 12*12 | |
Reference outer diameter | mm | 18.5 | 18.5 | 20.0 | 21.0 | 22.5 | 24.5 | 26.0 |
Center strength member | Material | Steel wire | ||||||
Water blocking material | Material | Water blocking cable gel | ||||||
Damp-proof layer | Material | / | ||||||
Armored layer | Material | Corrugated aluminium belt | ||||||
Inner sheath | Thickness(±0.1mm) | 1.0 | ||||||
Armored layer | Material layer | Corrugated steel belt | ||||||
Inner sheath | Thickness(±0.1mm) | 1.0 | ||||||
Armored layer | Material | Single galvanized steel wire | ||||||
Outer sheath | Thickness(±0.2mm) | 1.8 | ||||||
Range of operating temperature | ℃ | -40- +70 | ||||||
Pull | short-term /long-term(N) | 8000/2000 | ||||||
Flatten | 6000/3000 | |||||||
*According to customer's requirements, the stranded loose tube armored cable can customize other structures or cores. |
G.652.D | G.655 | 50/125μm | 62.5/125μm | ||
Attenuation | @850nm | - | - | ≤3.0dB/km | ≤3.0dB/km |
@1300nm | - | - | ≤1.0dB/km | ≤1.0dB/km | |
@1310nm | ≤0.36dB/km | ≤0.36dB/km | - | - | |
@1550nm | ≤0.22dB/km | ≤0.23dB/km | - | - | |
Band width | @850nm | - | - | ≥500MHz·km | ≥200MHz·km |
@1300nm | - | - | ≥1000MHz·km | ≥600MHz·km | |
Fiber cutoff wavelength | ≤1260nm | ≤1260nm | - | - | |
Polarization Mode Dispersion | Single optical fiber | ≤0.20ps/√km | ≤0.20ps/√km | - | - |
Link value(M=20,Q=0.01%) | ≤0.10ps/√km | ≤0.10ps/√km | - | - |
Item | Inspection standard | Specified value | Requirements |
Pull | IEC 60794-1-2-E1 | According to technical parameter | Additional attenuation for short term:≤0.1dB |
Flatten | IEC 60794-1-2-E3 | According to technical parameter | Additional attenuation for short term:≤0.1dB |
Impact | IEC 60794-1-2-E4 | The height is 1 meter punch hammer 450g at least 50 times | Residual additional attenuation:≤0.03dB |
Backward and forward bending | IEC 60794-1-2-E6 | Loading 150N 30times | Residual additional attenuation:≤0.03dB |
Twisting | IEC 60794-1-2-E7 | 1 meter ±180° 10times | Residual additional attenuation:≤0.03dB |
Temperature recycle test | IEC 60794-1-2-F1 | -40℃ +70℃ | Change of additional attenuation: ≤0.05dB/km |
* The monitoring of all optical fiber attenuation's change is operated in wavelength of 1550nm. |
Conduit, aerial, Directly burial