The cable features an insert of single-mode or multi-mode into loose tube made of high modulus polyester material and filled with water proof compounds. The center of cable core is a metallic strength core. For the cables with a certain number of cores, the metallic strength core sheathed with polyethylene (PE). The loose tube (and filling rope) is twisted around the central strength core to form a compact circular core, whose cracks are filled with water blocking materials. Extruded polyethylene sheath is inserted into cable after the double chromium-plated plastic steel tape is vertically wrapped. Finally, an extruded polyethylene sheath into cable after armored of single steel wire.
Application of Stranded Loose Tube Non-metallic Armored CableThe stranded loose tube single steel wire armored cable is suitable for Long distance and interoffice communication.
Parameter 1. Technical parameterItem | Content | Value | ||||||
Number of cable cores | 24 | 36 | 48 | 72 | 96 | 120 | 144 | |
Loose tube | Outer diameter | 1.8 | 2.5 | 2.5 | 2.5 | 2.5 | 2.5 | 2.5 |
Number of Loose Tube* number of cores per tube | 4*6 | 6*6 | 4*12 | 6*12 | 8*12 | 10*12 | 12*12 | |
Reference outer diameter | mm | 18.5 | 18.5 | 20.0 | 21.0 | 22.5 | 24.5 | 26.0 |
Center strength member | Material | Steel wire | ||||||
Water blocking material | Material | Water blocking cable gel | ||||||
Damp-proof layer | Material | / | ||||||
Armored layer | Material | Corrugated aluminium belt | ||||||
Inner sheath | Thickness(±0.1mm) | 1.0 | ||||||
Armored layer | Material layer | Corrugated steel belt | ||||||
Inner sheath | Thickness(±0.1mm) | 1.0 | ||||||
Armored layer | Material | Single galvanized steel wire | ||||||
Outer sheath | Thickness(±0.2mm) | 1.8 | ||||||
Range of operating temperature | ℃ | -40- +70 | ||||||
Pull | short-term /long-term(N) | 8000/2000 | ||||||
Flatten | 6000/3000 | |||||||
*According to customer's requirements, the stranded loose tube armored cable can customize other structures or cores. |
G.652.D | G.655 | 50/125μm | 62.5/125μm | ||
Attenuation | @850nm | - | - | ≤3.0dB/km | ≤3.0dB/km |
@1300nm | - | - | ≤1.0dB/km | ≤1.0dB/km | |
@1310nm | ≤0.36dB/km | ≤0.36dB/km | - | - | |
@1550nm | ≤0.22dB/km | ≤0.23dB/km | - | - | |
Band width | @850nm | - | - | ≥500MHz·km | ≥200MHz·km |
@1300nm | - | - | ≥1000MHz·km | ≥600MHz·km | |
Fiber cutoff wavelength | ≤1260nm | ≤1260nm | - | - | |
Polarization Mode Dispersion | Single optical fiber | ≤0.20ps/√km | ≤0.20ps/√km | - | - |
Link value(M=20,Q=0.01%) | ≤0.10ps/√km | ≤0.10ps/√km | - | - |
Item | Inspection standard | Specified value | Requirements |
Pull | IEC 60794-1-2-E1 | According to technical parameter | Additional attenuation for short term:≤0.1dB |
Flatten | IEC 60794-1-2-E3 | According to technical parameter | Additional attenuation for short term:≤0.1dB |
Impact | IEC 60794-1-2-E4 | The height is 1 meter punch hammer 450g at least 50 times | Residual additional attenuation:≤0.03dB |
Backward and forward bending | IEC 60794-1-2-E6 | Loading 150N 30times | Residual additional attenuation:≤0.03dB |
Twisting | IEC 60794-1-2-E7 | 1 meter ±180° 10times | Residual additional attenuation:≤0.03dB |
Temperature recycle test | IEC 60794-1-2-F1 | -40℃ +70℃ | Change of additional attenuation: ≤0.05dB/km |
* The monitoring of all optical fiber attenuation's change is operated in wavelength of 1550nm. |
Conduit, aerial, Directly burial