During the petrochemical production process, the chlorine from feed gas can poison various catalysts and adsorbents, and deactivate their adsorbing performance and catalytic performance. The presence of chlorine also seriously corrodes the device and equipment, which affects the normal production operations, making chlorine removal a necessary step. A solid antichlor is most often used for this process.
Chemical composition (wt%)
Advantage
This 104A activated alumina antichlor features a wide operating temperature range, uniform activity under high temperature and low temperature, excellent water resistance, and it ensures the high anti-mobility of active component and chloride after reaction.
Service conditions
Temperature: 5-400℃
Pressure: atmospheric pressure -- 0.8Mpa
Space velocity : 1000-3000h-1
Bed height-diameter ratio: >3
Chloride removal rate: ≥99.9%
Appearance | White spherical |
Specification (mm) | 3.0-5.0 |
Compressive strength( N/sphere ) | ≥120 |
Specific surface area( m2/g ) | ≥130 |
Bulk density (g/cm3 ) | 0.75-0.80 |
Penetration of chlorine capacity | 50℃≥12% 350℃ ≥22% |
Package and notes
25kg/bags, 25kg/barrels packaging (lining plastic bag)
This product needs to be kept dry. It cannot be cast during the transportation, loading and unloading process, and must be airtight sealed when not in use.