Description
The GP33 series of low frequency online UPS is the most advanced and intelligent uninterruptible power system we provide. It combines a high-speed micro control unit (MCU), complex programmable logic device (CPLD), the sixth generation of low-loss high-power IGBT, and the static switch.
Our low frequency online battery backup is equipped with a LCD display and its apparent power ranges from 10 to 400 KVA.
Application
The 10-400KVA online UPS with LCD display is widely utilized in data sensitive locations such as banks, security sectors, large enterprises, and data exchange centers.
Main Features
1. The high definition LCD touch screen and LED indicator can clearly show the operating parameters and work status of the online UPS.
2. The modular design adopted saves resources while enabling easy maintenance.
3. Our low frequency online UPS adopts non-circumfluence control circuit, which saves electricity. It is equipped with a new turbofan which shows excellent heat dissipation performance and is highly energy-saving.
4. Adopting green rectifier and inverter technologies, our product provides users with clear energy.
5. Due to the adoption of advanced digital circuits, this uninterruptible power supply has its service life prolonged by 80%.
6. Excellent load capacity allows our uninterruptible power source to fully adapt to extreme load changes, e.g. from 0 to 100%, without switching to bypass. Also, stable and reliable output is guaranteed
7. Our low frequency UPS offers robust protection functions against issues such as overheating, input surge, phase failure, output overload, short circuit, input/output under voltage overflow, battery over charge/discharge, etc. The alarm function will alert you of any abnormalities.
8. The three phases are controlled separately, so as to realize the control of transient overload balance degree. The 100% unbalance of three-phase load is allowable.
9. The optional input harmonic filter or twelve-pulse rectifier can effectively inhibit input harmonic pollution, improve the input power factor, and reduce the input harmonic current.
10. A battery inspection module is available. Our three-phase online UPS can measure a single parameter and show it on the LCD display. If there is a battery fault, an alarm will be issued to notify the administrator.
11. The operating mode of the uninterruptible power system can be set according to the electricity requirements. Users can choose between the UPS operating mode, ECO energy-saving operating mode, and the EPS operating mode.
Model | GP3310 ~ GP33200 | |||||||||||
Capacity (VA) | 10K | 15K | 20K | 30K | 40K | 60K | 80K | 100K | 120K | 160K | 200K | |
Nominal output capacity | 8KW | 12KW | 16KW | 24KW | 32KW | 48KW | 64KW | 80KW | 96KW | 128KW | 160KW | |
Operate type | Double conversion low frequency online type | |||||||||||
Input | voltage | 220V/380, 230/400, 240/415V, ±25% | ||||||||||
Phase | Three phase N G | |||||||||||
Frequency | 50Hz/60Hz±5% | |||||||||||
Input power factor | 0.95 (with input filter) | |||||||||||
Soft start | 0-100% 5sec | |||||||||||
Output | Voltage | 220V/380, 230/400, 240/415V, ±1% (stable load), ±5% (active load) | ||||||||||
Phase | Three phase N G | |||||||||||
Frequency | 50/60Hz (1±5%, AC mode), 50/60Hz (±1%, Battery mode) | |||||||||||
Power factor | 0.8 | |||||||||||
Output wave | Pure sine wave | |||||||||||
Distortion | Linear load <3%, non linear load<5% | |||||||||||
Battery voltage | Standard battery voltage | 360V/384V | ||||||||||
Floating charge | 405V/432V | |||||||||||
Terminal voltage | 315V/336V | |||||||||||
Charge current | 1A-50A (Can calculate and set according to battery configuration software) | |||||||||||
Maximum discharge current | 28 | 42 | 56 | 85 | 113 | 169 | 225 | 282 | 338 | 381 | 507 | |
Main Function | Active voltage change | 0-100%±5% | ||||||||||
Instant recover time | <10ms | |||||||||||
Imbalance voltage | <±5%,<±1%( Balance load voltage) | |||||||||||
Overload capacity | 125% for 10min,150% for 1min | |||||||||||
Static switch | Automatic | |||||||||||
Protection | Protection against over current, short circuit, battery low voltage, over heat | |||||||||||
Cold method | Compel aeration (temperature control mode) | |||||||||||
Noise | 60-65dB | |||||||||||
Display | LED, LCD display | |||||||||||
Communication port (Optional) | RS232, SNMP, dry-contact | |||||||||||
Alarm | Alarm with buzzer and indicators | |||||||||||
Environment | Temperature: 0-40℃Humidity: 0-90% | |||||||||||
Net Weight | kg | 210 | 258 | 350 | 400 | 480 | 900 | 1100 | 1200 | 1250 | 1380 | 1520 |
Size | L×W×H (mm) | 700×520×1100 | 800×600×1200 | 800×600×1500 | 1200×900×1600 | 2000×900×1800 |
As a China-based 10-400KVA online UPS with LCD display manufacturer and supplier, we also provide LED display home inverter charger, 400-1500VA offline UPS with LED display, rack mount UPS battery pack, etc.