Our HBT series of concrete pumps are widely used when mixing and pouring cement. Pumping must comply with JGJ/T10-95 concrete construction technology regulations.
Features of the Concrete Pump
1. The hydraulic system uses imported valves for good reliability.
2. The main electrical components for the concrete equipment are imported from well-known quality brands.
3. The distribution valve is reliable and offers high performance for gripping material.
4. The high capacity main oil pump maximizes its efficiency when the power is constant.
5. The specially designed blades mean there are few dead corners during mixing and the concrete pump can accommodate a variety of concrete formulas.
6. The trailer mounted concrete pump has automatic pistons which are easy to check and replace if needed.
7. A menu and display screen reduces the need for operating buttons. The electrical cabinet has IP65 protection grade.
8. The use of electric proportional control technology helps achieve the concrete pump's stepless regulation in pouring out concrete.
9. The cement pump is easy to maintain. All wearing parts can be conveniently installed and removed.
The way the concrete is mixed directly impacts the pump's efficiency and performance. In order for it to best work, users should have a thorough grasp on pumping concrete, including knowledge of the concrete's component, preparation, etc.
Technical Parameters of the Concrete PumpSpecifications | Items | Unit | HBT80-16-110S | HBT60-13-90S |
Theoretical Concrete Pumping Ability | m3/h | 80 | 60 | |
Theoretical Concrete Output Pressure | Mpa | 16 | 13 | |
Concrete Distributing Valve | “S” Valve | "S" Valve | ||
Concrete Cylinder Diameter × Max Stroke | mm | Φ200×1800 | Φ200×1600 | |
Hopper Capacity | L | 800 | 800 | |
Diameter of discharge | mm | Φ180 | Φ180 | |
Feeding Height | mm | 1400 | 1400 | |
Power system | Type of motors | Y2-315S-4 | Y2-280M-4 | |
Power of motors | kw | 110 | 90 | |
Rated voltage | V | ~380 | ~380 | |
Rated rotating speed | r/min | 1480 | 1480 | |
Hydraulic system | Type of oil system | Open circuit | Open circuit | |
Oil pressure of pumping system(safety valve set value) | MPa | 34 | 34 | |
Oil pressure distribution system(safety valve set value) | MPa | 23 | 23 | |
Oil pressure of mixing system(safety valve set value) | MPa | 14 | 14 | |
Max. Mixing rotating speed | r/min | 32 | 32 | |
Volume of hydraulic oil tank | L | 500 | 500 | |
Other parameters | Power of radiator fan motor | W | 370 | |
Rotating speed of fan | r/min | 1400 | ||
Allowable max. Aggregate size | mm | Cobble 50, macadam 40 | ||
Inner diameter of pumping pipe | mm | Φ125 | ||
L×W×H Outer size | mm | 6300×2100×2250 | 6000×2100×2250 | |
Total weight | kg | 6400 | 5800 |