As a universal mart temperature transmitter, the MIC101 temperature transmitter can convert resistance temperature detector (pt100, pt1000, Cu50, Cu100) and thermocouple (Type K, E, J, T, N, R, S, B) input signals into a scalable level of 4 to 20mA. It is directly installed to RTD Form B. Equipped with a special card, the transmitter can follow the DIN35 guide rail installation method.
Features
1. A compact structure is available.
2. With the central open hole, you can choose any installation method as you want.
3. The temperature transmitter can monitor the opens-and-shorts.
4. A self-monitoring function is well designed.
5. A handheld operator is configurable, and the configurable information can be stored.
6. Other features include high precision, low power dissipation, wide range of using environment temperature, and stable work performance.
7. The application range is quite wide, and the transmitter can be integrated with the RTD for the installation.
8. The electromagnetic compatibility is in accordance with the EN61326-1: 2006, EN61000-3-2: 2006 A1: 2009 A2: 2009, and EN61000-3-3: 2008.
Input | |
Measured variable | Temperature |
Measurement accuracy | 0.2% |
Output | |
Output signal | 4~ 20mA |
Load resistance | R L ≤ (U e -7.5) /0.021A |
Signal on alarm | I H = 20.5mA ; I L = 3.8mA |
Input sensor break, output current | 22mA |
Sensor open-circuit, output current | 22mA |
Sampling period | rating value 0.25s |
Protection | reverse polarity protection |
Essential parameter | |
Supply voltage | 7.5~ 45V, DC |
Temperature drift | 0.01% F.S./ ℃ |
Damping time | < 5s |
Insulation strength (between input and output) | 1500V, AC, 1 min |
Insulation resistance (between input and output) | ≥100MΩ |
Electromagnetic compatibility | EN61326-1: 2006 EN61000-3-2: 2006 A1: 2009 A2: 2009 EN61000-3-3: 2008 |
Minimum range | 50℃ |
Weight | 32g |
Rated operating condition - Environment temperature | |
Storage temperature | -50℃~ 105℃ |
Operating temperature | -40℃~ 85℃ |
Relative humidity | ≤85% |
Reference operating conditions | 23℃ |
Input | Type | Measurements ranges | Output accuracy |
Resistance temperature (RT) | Pt100 | -200℃~ 850℃ | 0.4℃/0.2% |
Pt1000 | -200℃~ 300℃ | 0.4℃/0.2% | |
Cu50 | -50℃~ 150℃ | 0.4℃/0.2% | |
Cu100 | -50℃~ 150℃ | 0.4℃/0.2% | |
※ The output accuracy error takes the greater one of the two values |
Input | Type | Measurements ranges | Output accuracy |
Thermocouples (TC) | T | -200℃~ 400℃ | 1℃/0.2% |
E | -200℃~ 1000℃ | 1℃/0.2% | |
J | -200℃~ 1200℃ | 1℃/0.2% | |
K | -200℃~ 1370℃ | 1℃/0.2% | |
N | -200℃~ 1300℃ | 1℃/0.2% | |
R | 0℃~ 1770℃ | 2℃/0.2% | |
S | 0℃~ 1770℃ | 2℃/0.2% | |
B | 600℃~ 1820℃ | 2℃/0.2% | |
※ The output accuracy error takes the greater one of the two values |
Reference conditions: 23℃ (73.4℉) ± 5℃
Configuration of MIC101 Temperature Transmitter
Configuration equipment: MIC101 series handheld operator TC100
Configuration setting: input sensor type and measuring range