Home RTD Extension Wire (Teflon Insulated Wire 2x7/0.2mm)

RTD Extension Wire (Teflon Insulated Wire 2x7/0.2mm)

Material of Teflon Insulated RTD Extension Wire
1. Conductors: nickel plated copper
2. Insulation: extruded TEF
3. Overall sheath: extruded SIL


1. Subject
This specification covers the requirements for teflon insulated and silicon rubber sheathed extension wire (2×7/0.2mm), which comes with strand wire and twisted construction.

RTD Extension Wire (Teflon Insulated Wire 2x7/0.2mm)
2. Technical Feature of Teflon Insulated RTD Extension Wire
A. Conductor
Stranded thermocouple extension wire
Conductor size (AWG) Quantity of strands and gauge
24 7/0.2mm


B. Insulation
Extruded TEF (200℃)
Nominal insulation thickness: 0.18±0.2 mm
Color code: red/white (1 core in white and 1 core in red)


C. Assembly
The two conductors (cores) of the RTD extension cable are in a twisted structure.


D. Overall sheath
Silicone rubber (200℃)
Nominal insulation thickness: 0.60±0.2 mm
Color code: grey


3. Dimensions and Tolerance of Teflon Insulated RTD Extension Wire
Dimensions/tolerance (mm): Ø3.23±0.25