Air volume | 340÷2490m3/h |
Cooling capacity | 2.16÷13.1kW |
Features of Concealed Ceiling Mounted Fan Coil Unit
1. Smaller volume. Of a laconic structure, this concealed ceiling mounted fan coil unit is only as thick as 230mm. Meanwhile, it is easy to install the unit and conduct the piping work and wire connection work;
2. High efficiency. This concealed ceiling mounted fan coil unit is manufactured with advanced expansion lock techniques which ensures the close contact between cooper tube and aluminum fin both of which are the indispensable parts of the heat exchanger. Therefore, the later enjoys quite highly efficient heat transferring performance;
3. Low noise. Thanks to its low noise motor fan, scientific airflow design and sound-absorbing and insulation materials, this commercial fan coil apparatus could operate with quite low noise which is lower than the national standard of 1-3Db(A). The standard static pressure is 12Pa and the high static pressure 30Pa;
4. Low energy consumption. The three-speed motor fan of this concealed mounted ari conditioning unit would effectively cooperate with the heat exchanger and enable users to adjust the air volume, helping reducing energy consumption.
Technical Advantages of Concealed Ceiling Mounted Fan Coil Unit
Based on our years' R&D and manufacturing experience, HUICON has provided many reliable commercial and civilian fan coil units which are made with advanced techniques both at home and abroad. Of excellent cooling performances, our fan coil unit, a reliable terminal device of central air condition system, enjoy rich types and could be applied in various occasions such as apartment, hotel, hospital, office building and shopping mall.
Model | 3-row coil 1-row coil(4-row coil) | ||||||||||
HEP-34 | HEP-51 | HEP-68 | HEP-85 | HEP-102 | HEP-136 | HEP-170 | HEP-204 | HEP-238 | |||
Nominal air volume(m3/h) | 340 | 510 | 680 | 850 | 1020 | 1360 | 1700 | 2040 | 2380 | ||
Nominal cooling capacity (W) | 2293 | 3180 | 3920 | 5006 | 5991 | 7841 | 9652 | 11454 | 13423 | ||
Nominal heating capacity(W) | 1596 | 2265 | 2887 | 3482 | 4146 | 5434 | 6354 | 7751 | 9034 | ||
fan | Type | Forward curved centrifugal fans with double inlets and small blades | |||||||||
quantity | 1 | 2 | 2 | 2 | 2 | 3 | 4 | 4 | 4 | ||
Motor | power | 220V~50Hz | |||||||||
Input power | Common type | 36 | 51 | 61 | 75 | 96 | 133 | 151 | 188 | 227 | |
High-pressure type | 43 | 58 | 71 | 86 | 107 | 155 | 173 | 211 | 253 | ||
Waterflow(l/min) | 6.57/2.28 | 9.1/3.24 | 11.24/4.13 | 14.35/4.98 | 17.17/5.94 | 22.4/7.78 | 27.66/9.1 | 32.8/11.1 | 39.44/12.94 | ||
Cold water resistance(kPa) | 2.36 | 5.51 | 10.43 | 17.06 | 25.25 | 8.53 | 13.41 | 20.72 | 29.86 | ||
Hot water resistance(kPa) | 1.79 | 4.19 | 7.93 | 10.07 | 19.2 | 6.49 | 10.2 | 15.75 | 22.7 | ||
Noise dB(A) | Common type | 37 | 39 | 41 | 43 | 45 | 46 | 48 | 50 | 52 | |
High pressure type | 40 | 42 | 44 | 46 | 47 | 48 | 50 | 52 | 54 | ||
Heat exchanger | components | Cooper tube, aluminum fin and mechanical expansion pipe | |||||||||
Maximum operating pressure | 1.6Mpa | ||||||||||
Piping | Cooling: water inlet pipe: Rp3/4" condensate pipe: R3/4; Heating: water inlet pipe: 3/8" | ||||||||||
Weight(kg) | WA | 15.5 | 18 | 20 | 23 | 25 | 32 | 36 | 38 | 55 | |
WAP1,2 | 18.5 | 23 | 25 | 28 | 31 | 40 | 46 | 50 | 69 |
Please note that
1. The noise data are measured as the unit is placed in an anechoic chamber and the measuring device keeps 1 meter away from the unit;
2. The standard working condition is:
cooling mode: DB/WB: 27℃/19 ℃, cooled water inlet: 7 ℃, temperature difference between the water inlet and outlet: 5 ℃;
heating mode: DB: 21 ℃, heated water inlet temperature: 60 ℃;
3. The static pressure of standard unit is 12Pa and that of the high static pressure type is 30Pa;
4. Data in the above table is measured when the fan is set with high air volume(the medium and low air volumes are respectively 80% and 60% of that of the high air volume).
Model | 3-row coil | ||||||||||
HEP-34 | HEP-51 | HEP-68 | HEP-85 | HEP-102 | HEP-136 | HEP-170 | HEP-204 | HEP-238 | |||
Nominal air volume (m3/h) | 340 | 510 | 680 | 850 | 1020 | 1360 | 1700 | 2040 | 2380 | ||
Nominal cooling capacity | 2165 | 3000 | 3733 | 4814 | 5652 | 7540 | 9420 | 11230 | 13100 | ||
Nominal heating capacity | 3456 | 4687 | 5973 | 7472 | 8885 | 11243 | 14120 | 17226 | 19360 | ||
Fan | type | Forward curved centrifugal fans with double inlets and small blades | |||||||||
Quantity | 1 | 2 | 2 | 2 | 2 | 3 | 4 | 4 | 4 | ||
Motor | Power | 220V~50Hz | |||||||||
Input power | Common type | 33 | 40 | 62 | 76 | 95 | 134 | 152 | 189 | 228 | |
High pressure type | 40 | 50 | 72 | 87 | 106 | 144 | 174 | 209 | 253 | ||
Waterflow(l/min) | 6.2 | 8.6 | 10.7 | 13.8 | 16.2 | 22.2 | 27.8 | 33.1 | 38.6 | ||
Water drop(kPa ) | 5.65 | 10.01 | 14.8 | 23.2 | 30.78 | 16 | 23.67 | 32.14 | 42.21 | ||
Noise dB(A) | Common type | 37 | 39 | 41 | 43 | 45 | 46 | 48 | 50 | 52 | |
High pressure type | 40 | 42 | 44 | 46 | 47 | 48 | 50 | 52 | 54 | ||
Heat exchanger | components | Cooper tube, aluminum fin and mechanical expansion pipe | |||||||||
Maximum operation pressure | 1.6Mpa | ||||||||||
Piping | Cooling: water inlet pipe: Rp3/4" condensate pipe: R3/4. | ||||||||||
Weight(kg) | WA | 15 | 17 | 19 | 22 | 24 | 30 | 34 | 36 | 53 | |
WAP1,2 | 18 | 22 | 24 | 27 | 30 | 38 | 44 | 48 | 67 | ||
WM | 31 | 33 | 36 | 38 | 38 | 55 | 62 | 72 | 77 | ||
LA | 18 | 21 | 23 | 24 | 26 | 37 | 41 | 48 | 60 | ||
LM | 29 | 31 | 33 | 35 | 38 | 52 | 58 | 69 | 85 | ||
KBM | 34 | 36 | 39 | 41 | 44 | 52 | 54 | 59 | 69 | ||
KQM | / | 30 | 39 | 46 | 46 | 51 | 59 | 59 | / |
Please note that
1. The noise data are measured as the unit is placed in an anechoic chamber and the measuring device keeps 1 meter away from the unit;
2. The standard working condition is:
cooling mode: DB/WB: 27℃/19 ℃, cooled water inlet: 7 ℃, temperature difference between the water inlet and outlet: 5 ℃;
heating mode: DB: 21 ℃, heated water inlet temperature: 60 ℃;
3. The static pressure of standard unit is 12Pa and that of the high static pressure type is 30Pa;
4. Data in the above table is measured when the fan is set with high air volume(the medium and low air volumes are respectively 80% and 60% of that of the high air volume).
Model | 2-row coil | ||||||||||
HEP-34 | HEP-51 | HEP-68 | HEP-85 | HEP-102 | HEP-136 | HEP-170 | HEP-204 | HEP-238 | |||
Nominal air volume (m3/h) | 360 | 510 | 720 | 900 | 1070 | 1430 | 1790 | 2140 | 2490 | ||
Nominal cooling capacity(W) | 1800 | 2700 | 3600 | 4500 | 5400 | 7200 | 9000 | 10800 | 12600 | ||
Nominal heating capacity(W) | 3150 | 4250 | 5640 | 6800 | 8090 | 10880 | 13590 | 16650 | 18900 | ||
Fan | Type | Forward curved centrifugal fans with double inlets and small blades | |||||||||
Quantity | 1 | 2 | 2 | 2 | 2 | 3 | 4 | 4 | 4 | ||
Motor | Power | 220V~50Hz | |||||||||
Input power | Common type | 37 | 52 | 62 | 76 | 96 | 134 | 152 | 189 | 228 | |
High pressure type | 44 | 59 | 72 | 87 | 108 | 156 | 174 | 212 | 253 | ||
Waterflow(l/min) | 5.3 | 8 | 10.3 | 13.3 | 15.9 | 21.2 | 26.6 | 31.9 | 37.2 | ||
Water drop(kPa) | 6.1 | 15.6 | 28.7 | 42 | 57 | 30.8 | 44.52 | 59.8 | 72.5 | ||
Noise dB(A) | Common type | 37 | 39 | 41 | 43 | 45 | 46 | 48 | 50 | 52 | |
High static pressure type | 40 | 42 | 44 | 46 | 47 | 48 | 50 | 52 | 54 | ||
Heat exchanger | Component | Cooper tube, aluminum fin and mechanical expansion pipe | |||||||||
Maximum operation pressure | 1.6Mpa | ||||||||||
Piping | Cooling: water inlet pipe: Rp3/4", outlet pipe: Rp3/4", condensate pipe: R3/4; | ||||||||||
Weight (kg) | WA | 14 | 16 | 18 | 21 | 23 | 28 | 32 | 34 | 51 | |
WAP1,2 | 17 | 21 | 23 | 26 | 29 | 36 | 42 | 46 | 65 | ||
WM | 30 | 32 | 35 | 37 | 40 | 53 | 60 | 70 | 75 | ||
LA | 17 | 20 | 22 | 23 | 25 | 35 | 39 | 46 | 58 | ||
LM | 28 | 30 | 32 | 34 | 37 | 50 | 56 | 67 | 83 |
Please note that
1. The noise data are measured as the unit is placed in an anechoic chamber and the measuring device keeps 1 meter away from the unit;
2. The standard working condition is:
cooling mode: DB/WB: 27℃/19 ℃, cooled water inlet: 7 ℃, temperature difference between the water inlet and outlet: 5 ℃;
heating mode: DB: 21 ℃, heated water inlet temperature: 60 ℃;
3. The static pressure of standard unit is 12Pa and that of the high static pressure type is 30Pa;
4. Data in the above table is measured when the fan is set with high air volume(the medium and low air volumes are respectively 80% and 60% of that of the high air volume).