Home Combustible Gas Detector

Combustible Gas Detector

The HM-701 series high-stability combustible gas detector is particularly for detecting the combustible gas leakage. By utilizing the high-end semiconductor gas sensing element, it works stably and can serve for a long time. The installation is also easy. The product is outfitted with the MCU internally for central control process. And each functional module directly or indirectly connects with the I/O port of MCU. The program solidified in the internal of MCU can complete the normal work of each functional module. Thus, the product can be guaranteed to work more stably, reliably and safely.


Meanwhile, the combustible gas detector adopts SMT production technology, enabling strong stability. Its outer shell is fabricated from the ABS fireproof material, and the PCB board utilizes the glass fiber material. The automatic fault detection indication function is also available. The product can drive the manipulator. Designed with stylish appearance, it is suitable for various household environments. The product can also be applicable for villa, hotel, apartment, and other places for security monitoring.



Model and Function
Model Operating Voltage Alarm Indication Basic Function
HM-701NS-AC AC200-240V or AC110V 85dB Alarm Sound, Red LED Indicator Flashing No Relay Output Signal
HM-701NVS-AC AC200-240V or AC110V Sound and Flash Alarm No Relay Output, Outputting A 12V Pulse Voltage for Driving the Electromagnetic Valve to Close the Gas Source When Raising the Alarm
HM-701NC-AC AC200-240V or AC110V 85dB Alarm Sound, LED Indicator Flashing Relay Operating with a Normally Open or Normally Closed Signal for Connecting Alarm Host
HM-701NVC-AC AC200-240V or AC110V Sound and Flash Alarm Outputting A Relay Output Signal for Connecting Alarm Controller, and Outputting A DC12V Pulse Voltage for Driving Electromagnetic Valve to Cut off the Gas Source
HM-701NC-DC DC9-24V Sound and Flash Alarm Outputting A Relay Output Signal for Connecting Alarm Controller When Raising the Alarm
HM-701NVC-DC DC9-24V Alarm Sound, LED Indicator Flashing Outputting A Relay Signal and A DC12V Pulse Voltage for Controlling the Electromagnetic Valve to Cut off the Gas Source
HM-701LC-DC DC9-24V The product exploits the low power consumption sensor and works with low power. It is often employed in the place insufficient with power supply. After the alarm, the product outputs a replay signal to connect the alarm controller.


Technical Specification (Part 1)
Model HM-701NS-AC HM-701NVS-AC HM-701NC-AC HM-701NVC-AC
Type Independent Type Independent Type with 12V Pulse Output to Drive Electromagnetic Valve Network Type Network Type with 12V Pulse Output to Drive Electromagnetic Valve
Operating Voltage AC110V or 220V
Rated Power ≤3W
Sensor High-stability Semiconductor Sensor
Alarm Concentration 10% (± 5%) Lower Explosive Limit of Natural Gas
Alarm Sound Pressure 85dB/m
Indicator Power Source: Green LED Indicator Normally onAlarm: Red LED Indicator Flashing and Buzzer Emitting the SoundFault: Yellow LED Indicator Normally on and Buzzer Emitting the Sound
Alarm Output Not Available 12V Pulse Output Normally Closed or Normally Open Relay Output Normally Closed or Normally Open Relay Output and 12V Pulse Output
Auxiliary Output Manipulator Controlling Signal
Manipulator Signal DC12V 300ms
Warm-up Time About 180 Seconds
Working Environment Temperature Range: -10℃ ~ 55℃Humidity Range: 10%~95% RH (No Condensation Phenomenon)
Mounting Mode Wall Mounted Mode
Dimension 115×72×41mm


Technical Specification (Part 2)
Model HM-701NC-DC HM-701NVC-DC HM-701LC-DC
Type Network Type Network Type with 12V Pulse Output to Drive Electromagnetic Valve Network Type, Low Power Consumption Design
Rated Power ≤3W
Operating Voltage DC9-24V
Sensor High-stability Semiconductor Sensor
Alarm Concentration 10% (± 5%) Lower Explosive Limit of Natural Gas
Alarm Sound Pressure 85dB/m
Indicator Power Source: Green LED Indicator Normally onAlarm: Red LED Indicator Flashing and Buzzer Emitting the SoundFault: Yellow LED Indicator Normally on and Buzzer Emitting the Sound
Alarm Output Normally Closed or Normally Open Relay Output Normally Closed or Normally Open Relay Output and 12V Pulse Output Normally Closed or Normally Open Relay Output
Auxiliary Output Manipulator Controlling Signal
Manipulator Signal DC12V 300ms
Warm-up Time About 180 Seconds
Working Environment Temperature Range: -10℃ ~ 55℃Humidity Range: 10%~95% RH (No Condensation Phenomenon)
Mounting Mode Wall Mounted Mode
Dimension 115×72×41mm


Instruction
1. For guaranteeing the sensitivity of the combustible gas detector, the user should clean the surface of the product with banister brush every one month. Before cleaning, the power should be cut off first.
2. It's not proper to spray the air freshener, hairspray, paint or other aerosol around the product.
3. The semiconductor sensor of the product can serve for 5 years. After serving for over 5 years, it should be replaced.
4. Do not clean the product with detergent remover or the solvent.
5. The chemical can cause permanent damage or temporary pollution to the product.
6. During the use process, if the combustible gas detector has the problem, please contact with the supplier timely. Do not dismantle and repair the product without permission for avoiding the accident.

Combustible Gas Detector

Packaging
Packaging Mode Heiman Packing, Customers' Packing, Neutral Packing, White-box Packing
Quantity 90pcs/box
Net/Gross Weight 23/25kg
Carton Size 560×468×355mm


Note: The packing mode is selectable to meet the needs of customers.