The HM-701 series high-stability combustible gas detector is particularly for detecting the combustible gas leakage. By utilizing the high-end semiconductor gas sensing element, it works stably and can serve for a long time. The installation is also easy. The product is outfitted with the MCU internally for central control process. And each functional module directly or indirectly connects with the I/O port of MCU. The program solidified in the internal of MCU can complete the normal work of each functional module. Thus, the product can be guaranteed to work more stably, reliably and safely.
Meanwhile, the combustible gas detector adopts SMT production technology, enabling strong stability. Its outer shell is fabricated from the ABS fireproof material, and the PCB board utilizes the glass fiber material. The automatic fault detection indication function is also available. The product can drive the manipulator. Designed with stylish appearance, it is suitable for various household environments. The product can also be applicable for villa, hotel, apartment, and other places for security monitoring.
Model | Operating Voltage | Alarm Indication | Basic Function |
HM-701NS-AC | AC200-240V or AC110V | 85dB Alarm Sound, Red LED Indicator Flashing | No Relay Output Signal |
HM-701NVS-AC | AC200-240V or AC110V | Sound and Flash Alarm | No Relay Output, Outputting A 12V Pulse Voltage for Driving the Electromagnetic Valve to Close the Gas Source When Raising the Alarm |
HM-701NC-AC | AC200-240V or AC110V | 85dB Alarm Sound, LED Indicator Flashing | Relay Operating with a Normally Open or Normally Closed Signal for Connecting Alarm Host |
HM-701NVC-AC | AC200-240V or AC110V | Sound and Flash Alarm | Outputting A Relay Output Signal for Connecting Alarm Controller, and Outputting A DC12V Pulse Voltage for Driving Electromagnetic Valve to Cut off the Gas Source |
HM-701NC-DC | DC9-24V | Sound and Flash Alarm | Outputting A Relay Output Signal for Connecting Alarm Controller When Raising the Alarm |
HM-701NVC-DC | DC9-24V | Alarm Sound, LED Indicator Flashing | Outputting A Relay Signal and A DC12V Pulse Voltage for Controlling the Electromagnetic Valve to Cut off the Gas Source |
HM-701LC-DC | DC9-24V | The product exploits the low power consumption sensor and works with low power. It is often employed in the place insufficient with power supply. After the alarm, the product outputs a replay signal to connect the alarm controller. |
Model | HM-701NS-AC | HM-701NVS-AC | HM-701NC-AC | HM-701NVC-AC |
Type | Independent Type | Independent Type with 12V Pulse Output to Drive Electromagnetic Valve | Network Type | Network Type with 12V Pulse Output to Drive Electromagnetic Valve |
Operating Voltage | AC110V or 220V | |||
Rated Power | ≤3W | |||
Sensor | High-stability Semiconductor Sensor | |||
Alarm Concentration | 10% (± 5%) Lower Explosive Limit of Natural Gas | |||
Alarm Sound Pressure | 85dB/m | |||
Indicator | Power Source: Green LED Indicator Normally onAlarm: Red LED Indicator Flashing and Buzzer Emitting the SoundFault: Yellow LED Indicator Normally on and Buzzer Emitting the Sound | |||
Alarm Output | Not Available | 12V Pulse Output | Normally Closed or Normally Open Relay Output | Normally Closed or Normally Open Relay Output and 12V Pulse Output |
Auxiliary Output | Manipulator Controlling Signal | |||
Manipulator Signal | DC12V 300ms | |||
Warm-up Time | About 180 Seconds | |||
Working Environment | Temperature Range: -10℃ ~ 55℃Humidity Range: 10%~95% RH (No Condensation Phenomenon) | |||
Mounting Mode | Wall Mounted Mode | |||
Dimension | 115×72×41mm |
Model | HM-701NC-DC | HM-701NVC-DC | HM-701LC-DC |
Type | Network Type | Network Type with 12V Pulse Output to Drive Electromagnetic Valve | Network Type, Low Power Consumption Design |
Rated Power | ≤3W | ||
Operating Voltage | DC9-24V | ||
Sensor | High-stability Semiconductor Sensor | ||
Alarm Concentration | 10% (± 5%) Lower Explosive Limit of Natural Gas | ||
Alarm Sound Pressure | 85dB/m | ||
Indicator | Power Source: Green LED Indicator Normally onAlarm: Red LED Indicator Flashing and Buzzer Emitting the SoundFault: Yellow LED Indicator Normally on and Buzzer Emitting the Sound | ||
Alarm Output | Normally Closed or Normally Open Relay Output | Normally Closed or Normally Open Relay Output and 12V Pulse Output | Normally Closed or Normally Open Relay Output |
Auxiliary Output | Manipulator Controlling Signal | ||
Manipulator Signal | DC12V 300ms | ||
Warm-up Time | About 180 Seconds | ||
Working Environment | Temperature Range: -10℃ ~ 55℃Humidity Range: 10%~95% RH (No Condensation Phenomenon) | ||
Mounting Mode | Wall Mounted Mode | ||
Dimension | 115×72×41mm |
Instruction
1. For guaranteeing the sensitivity of the combustible gas detector, the user should clean the surface of the product with banister brush every one month. Before cleaning, the power should be cut off first.
2. It's not proper to spray the air freshener, hairspray, paint or other aerosol around the product.
3. The semiconductor sensor of the product can serve for 5 years. After serving for over 5 years, it should be replaced.
4. Do not clean the product with detergent remover or the solvent.
5. The chemical can cause permanent damage or temporary pollution to the product.
6. During the use process, if the combustible gas detector has the problem, please contact with the supplier timely. Do not dismantle and repair the product without permission for avoiding the accident.
Packaging Mode | Heiman Packing, Customers' Packing, Neutral Packing, White-box Packing |
Quantity | 90pcs/box |
Net/Gross Weight | 23/25kg |
Carton Size | 560×468×355mm |
Note: The packing mode is selectable to meet the needs of customers.