General Introduction
The PTT series low frequency online UPS takes advantage of the static switch, state-of-the-art DSP technology, high speed microcontroller unit (MCU), complex programmable logic device (CPLD), and the 6th-generation low consumption high power insulated gate bipolar transistor (IGBT) to deliver stable and reliable performance. Moreover, it has large power capacity, and audible alarm is also achieved.
This is a world-class product, and it shows some remarkable properties as illustrated below.
1. Fully Digital Control Technology
a. Ultra stable digital circuit: Our product use advanced digital circuit to replace traditional analog circuit, realizing a great breakthrough in this field. With the help of this digital circuit, the MCU and CPLD could execute circuitry control, parameter setting and operation management in a perfect way, while the self-checking function is also beyond expectation. Moreover, sampling is carried out as long as our product works, and this technique is not only beneficial for self-checking and failure analysis of all the independent circuits on the circuit board, but also ensures stable and pure sine wave output, thus both our product and connected equipment will run in a stable way.
b. Intelligent battery management: This low frequency online UPS introduces an advanced battery management system to realize intelligent control of the battery. This management system adjusts the charge current according to battery configuration, and it also fits for equalizing charge and float charge switch, temperature compensated charging and discharge management. Aside from these, on the monitoring interface, operator could detect the running status of battery to ensure its working efficiency. In general, this intelligent battery management system helps operator manage the battery, and it can prolong battery life by 55% or even longer.
c. Intelligent detection system: The MCU will on-line detect power status, breaker state, fuse condition and working condition of all circuits in a continuous manner. If any failure occurs, the detection system will send alarm message to operator, and activate protection measures at the same time.
d. Parallel redundancy network: With the help of fully digital control technology, a parallel redundancy network of two or more UPS units is established.
2. Advanced Management Software
Our low frequency online UPS comes with a piece of management software to help users program this machine to realize flexible start up and shut down at predetermined time, and this software is also capable of battery discharge, equalizing charge, float charge and other functions. In this way, users will find it is very easy and convenient to manipulate this product.
3. High Precision SMD
Instead of conventional plug-in circuit, PTT series adopts high precision SMD to save space and eliminate undesired defects that are commonly seen for the traditional technology, thereby ensuring safe, reliable and precise running of the integrated circuit.
The combination of 4-layer circuit board and high precision SMD fully avoids interference of high-frequency signals that is generated by the chip itself to other chips, so every chip could work normally without being influenced by other ones, showing improved anti-interference property.
Moreover, due to the application of SMD technology, this online UPS shows the features of high accuracy, good resistance to high temperature, excellent filtering performance as well as stable overall performance, and its service life is extended by 80%.
In addition, the IGBT is characterized by high-speed switch, high working voltage and high working current, and the voltage type driving method requires small control power. The work efficiency of inverter is enhanced, and its temperature rise is small, realizing better reliability.
4. Information Processing Technology for Ultra Clear Interface
a. Audible alarm function is achieved.
b. The humanized large LCD screen allows users to view data in English or Chinese, and the running state of our product could be revealed directly. The touch button, and table-type data and event log facilitate your work greatly.
c. The LED indicators displays work flow status in an intuitive way.
5. Environmentally Friendly and Energy Saving Technology
As shown by the scientific life-cycle assessment which is a technique to assess environmental impacts associated with all the stages of a product's life from-cradle-to-grave, the PTT series online UPS possesses some outstanding properties when it comes to environment protection and energy conservation.
a. The touch panel shows superb resistance to ageing, and the machine body is processed by fluorocarbon paint. Hence, our product is durable and environmentally friendly.
b. The detachable modular design allows simple maintenance, and it also saves resources to a large extent.
c. A new kind of bearing is applied for the fan, and it has unrivaled heat dissipation effect and good energy saving performance.
d. The DLC consumes a little electricity during working, realizing the purpose of energy saving performance.
e. This low frequency online UPS is able to provide green energy with the help of rectification and inversion technologies.
6. Other Advantages
a. Excellent load characteristic: When load changes from 0% to 100%, our product is capable of providing stable and reliable output without being switched to the bypass circuit.
b. Perfect protections: Different kinds of protection functions are achieved, such as over temperature protection, input voltage surge protection, input/output overvoltage and under voltage protections, overcharge and overdischarge protections for battery, output overload and short circuit protections, etc.
c. High-performance dynamic characteristic: This online UPS adopts instantaneous control, effective value and other feedback controls to realize high-performance dynamic control, and the harmonic distortion of output voltage is cut down.
d. Optional input harmonic filter: This device could effectively suppress input harmonic pollution, thus enhancing input power factor and reducing input harmonic current.
e. Optional battery checking module: This module is able to detect parameters of the battery, and then reveals them on the display screen. If there is something wrong with the battery, it will alarm immediately to inform operators.
f. Individualized setting: According to practical applications, our product could be set at different work modes, including UPS working mode, ECO working mode, and EPS working mode.
Applications
Depending on the properties above, this low frequency online UPS has been widely accepted in variety of places, such as banking offices, automatic teller machines, communication base stations, billing centers of communication industry, as well as offices for power, transportation, securities, manufacturing and other industries.
Single-phase input single-phase output | 1K | 2K | 3K | 4K | 6K | 8K | 10K | 15K | 20K | |
Rated capacity | 800W | 1600W | 2400W | 3200W | 4800W | 6400W | 8000W | 12000W | 16000W | |
Product type | Low frequency double conversion online UPS | |||||||||
Phase number | Single phase (L N G) | |||||||||
Rectifier | Nominal input voltage | 220VAC | ||||||||
Input voltage range | ±25% | |||||||||
Nominal input frequency | 50Hz±10% | |||||||||
Input power factor | ≥0.85 | |||||||||
Ripple factor | <2% | |||||||||
Soft start | 0~100%, 5 seconds | |||||||||
Charge process | Charge mode | Charge at constant current first, and then at constant voltage. Temperature compensated charging, automatic switch between float charge and equalizing charge are also provided. | ||||||||
Float charge voltage | 55VDC | 220VDC | ||||||||
Equalizing charge voltage | 56.8VDC | 227VDC | ||||||||
Temperature compensating voltage | -3mV/℃ (single) | |||||||||
Charge current | 0.1C (Automatically adjusted according to settings of battery capacity) | |||||||||
Charge power | 40% of rated capacity | |||||||||
Battery | Type | Maintenance free lead-acid battery | ||||||||
Capacity | Adjustable within 7~999Ah (the capacity range changes with power) | |||||||||
Quantity | 8pcs of 12V-battery (total 96V) | 16pcs of 12V-battery (total 192V) | ||||||||
Inverter | Phase number | Single phase | ||||||||
Nominal voltage | 220VAC | |||||||||
Output voltage stability | ±1% for steady load, ±5% for fluctuated load | |||||||||
Frequency stability | 50Hz±0.5% (out of synchronization) | |||||||||
Crest factor | >3:1 | |||||||||
Output waveform and harmonic distortion | Sine wave, <3% for linear load, <5% for non-linear load | |||||||||
Dynamic characteristic | Transient voltage <±5% (change from 0% to 100%), recovery time<10ms | |||||||||
Overload protection | 115%: normal working | |||||||||
125%: 10 minutes, 150%: 1 minute | ||||||||||
200%: 1 second | ||||||||||
Efficiency | >93% at full load | |||||||||
Bypass | Phase number | Single phase (L N) | ||||||||
Nominal voltage | 220VAC | |||||||||
Transfer time | 0ms (static switch) | |||||||||
Protection | Input | Over/under voltage and frequency | ||||||||
Output | Over current, short circuit, low power factor | |||||||||
Battery | Overcharge, overdischarge | |||||||||
Temperature | High ambient/inverter temperature | |||||||||
Hardware | Abnormal auxiliary power supply, circuit breaker tripping, fuse break down, over current and overvoltage for power devices | |||||||||
System parameters | Work environment | Ambient temperature: 0℃~40℃ Relative humidity: 30%~90% Altitude: <1000m (the power drops by 1% with every increase of 100m in altitude, and the maximum height is 4000m) | ||||||||
Cooling method | Forced air cooling | |||||||||
Communication interface | RS232 and RS485. Dry contact interface and SNMP card are optional. | |||||||||
Current sharing unevenness for parallel operation | ≤3% | |||||||||
Redundancy | Series or parallel connected hot standby | |||||||||
Resistance to surge | 10/700μS, 5KV 8/20μS, 20KA | |||||||||
IP rating | IP20 | |||||||||
Safety performance | 3000VAC between input/output and ground, leakage current is lower than 3.5mA, and insulation resistance is over 2MΩ (500VDC). | |||||||||
Noise level | 45~50dB | 50~55dB | 55~60dB | 55~60dB | ||||||
Size (W×D×H) | 210×520×530mm | 220×520×640mm | 220×500×760mm | 450×600×1200mm | ||||||
Weight | 51kg | 58kg | 65kg | 70kg | 73kg | 85kg | 108kg | 265kg | 300kg |
Three-phase input single-phase output | 6K | 10K | 15K | 20K | 30K | 40K | 60K | 80K | |
Rated capacity | 6KVA | 10KVA | 15KVA | 20KVA | 30KVA | 40KVA | 60KVA | 80KVA | |
Product type | Double conversion online UPS | ||||||||
Phase number | Three phase (L N G) | ||||||||
Input power factor | >0.8 (>0.95 when with filter or 12-pulse rectifier) | ||||||||
Rectifier | Nominal input voltage | 220/380VAC, 230/400VAC, 240/415VAC | |||||||
Input voltage range | ±25% | ||||||||
Nominal input frequency | 50Hz±10%, 60Hz±10% | ||||||||
Ripple factor | <2% | ||||||||
Soft start | 0~100%, 5 seconds | ||||||||
Charge process | Charge mode | Charge at constant current first, and then at constant voltage. Temperature compensated charging, automatic switch between float charge and equalizing charge are also provided. | |||||||
Float charge voltage | 405VDC | ||||||||
Equalizing charge voltage | 432VDC | ||||||||
Temperature compensating voltage | -3mV/℃ (single) | ||||||||
Charge current | 0.1C (Automatically adjusted according to settings of battery capacity) | ||||||||
Charge power | 20% of rated capacity | ||||||||
Battery | Type | Maintenance free lead-acid battery | |||||||
Capacity | Adjustable within 7~999Ah (the capacity range changes with power) | ||||||||
Quantity | 30pcs of 12V-battery or 180pcs of 2V-battery (nominal voltage of 360VDC) | ||||||||
Inverter | Phase number | Single phase (L N G) | |||||||
Rated power | Rated capacity × 0.8 | ||||||||
Nominal voltage | 220VAC, 230VAC, 240VAC | ||||||||
Output voltage stability | ±1% for steady load, ±3% for fluctuated load | ||||||||
Frequency stability | 50Hz/60Hz±0.5% (out of synchronization) | ||||||||
Crest factor | >3:1 | ||||||||
Output waveform and harmonic distortion | Sine wave, < 3% for linear load, < 5% for non-linear load | ||||||||
Dynamic characteristic | Transient voltage < ±5% (change from 0 to 100), recovery time<10ms | ||||||||
Overload protection | 115%: normal working | ||||||||
125%: 10 minutes, 150%: 1 minute | |||||||||
200%: 1 second | |||||||||
Efficiency | >93% at full load | ||||||||
Bypass | Phase number | Single phase (L N) | |||||||
Nominal voltage | 220VAC (230VAC, 240VAC) | ||||||||
Transfer time | 0ms (static switch) | ||||||||
Protection | Input | Over/under voltage and frequency, phase loss and fault | |||||||
Output | Over current, short circuit, low power factor | ||||||||
Battery | Overcharge, overdischarge | ||||||||
Temperature | High ambient/inverter temperature | ||||||||
Hardware | Abnormal auxiliary power supply, circuit breaker tripping, fuse break down, over current and overvoltage for power devices | ||||||||
System parameters | Work environment | Ambient temperature: 0℃~40℃ Relative humidity: 30%~90% Altitude: < 1000m (the power drops by 1% with every increase of 100m in altitude, and the maximum height is 4000m) | |||||||
Cooling method | Forced air cooling | ||||||||
Communication interface | RS232 and RS485. Dry contact interface and SNMP card are optional. | ||||||||
Current sharing unevenness for parallel operation | ≤3% | ||||||||
Redundancy | Series or parallel connected hot standby | ||||||||
Resistance to surge | 10/700μS, 5KV 8/20μS, 20KA | ||||||||
IP rating | IP21 | ||||||||
Safety performance | 3000VAC between input/output and ground, leakage current is lower than 3.5mA, and insulation resistance is over 2MΩ (500VDC). | ||||||||
Noise level | 45~50dB | 50~55dB | 55~58dB | 55~60dB | |||||
Size (W×D×H) | 450×600×1200 | 600×720×1520 | 980×800×1800 | ||||||
Weight | 108kg | 146kg | 162kg | 178kg | 239kg | 318kg | 445kg | 498kg |
Three-phase input single-phase output | 6K | 10K | 15K | 20K | 30K | 40K | 60K | 80K | |
Rated capacity | 6KVA | 10KVA | 15KVA | 20KVA | 30KVA | 40KVA | 60KVA | 80KVA | |
Product type | Double conversion online UPS | ||||||||
Phase number | Three phase (L N G) | ||||||||
Input power factor | >0.8 (>0.95 when with filter or 12-pulse rectifier) | ||||||||
Rectifier | Nominal input voltage | 220/380VAC, 230/400VAC, 240/415VAC | |||||||
Input voltage range | ±25% | ||||||||
Nominal input frequency | 50Hz±10%, 60Hz±10% | ||||||||
Ripple factor | <2% | ||||||||
Soft start | 0~100%, 5 seconds | ||||||||
Charge process | Charge mode | Charge at constant current first, and then at constant voltage. Temperature compensated charging, automatic switch between float charge and equalizing charge are also provided. | |||||||
Float charge voltage | 405VDC | ||||||||
Equalizing charge voltage | 432VDC | ||||||||
Temperature compensating voltage | -3mV/℃ (single) | ||||||||
Charge current | 0.1C (Automatically adjusted according to settings of battery capacity) | ||||||||
Charge power | 20% of rated capacity | ||||||||
Battery | Type | Maintenance free lead-acid battery | |||||||
Capacity | Adjustable within 7~999Ah (the capacity range changes with power) | ||||||||
Quantity | 30pcs of 12V-battery or 180pcs of 2V-battery (nominal voltage of 360VDC) | ||||||||
Inverter | Phase number | Single phase (L N G) | |||||||
Rated power | Rated capacity × 0.8 | ||||||||
Nominal voltage | 220VAC, 230VAC, 240VAC | ||||||||
Output voltage stability | ±1% for steady load, ±3% for fluctuated load | ||||||||
Frequency stability | 50Hz/60Hz±0.5% (out of synchronization) | ||||||||
Crest factor | >3:1 | ||||||||
Output waveform and harmonic distortion | Sine wave, < 3% for linear load, < 5% for non-linear load | ||||||||
Dynamic characteristic | Transient voltage < ±5% (change from 0 to 100), recovery time < 10ms | ||||||||
Overload protection | 115%: normal working | ||||||||
125%: 10 minutes, 150%: 1 minute | |||||||||
200%: 1 second | |||||||||
Efficiency | >93% at full load | ||||||||
Bypass | Phase number | Single phase (L N) | |||||||
Nominal voltage | 220VAC (230VAC, 240VAC) | ||||||||
Transfer time | 0ms (static switch) | ||||||||
Protection | Input | Over/under voltage and frequency, phase loss and fault | |||||||
Output | Over current, short circuit, low power factor | ||||||||
Battery | Overcharge, overdischarge | ||||||||
Temperature | High ambient/inverter temperature | ||||||||
Hardware | Abnormal auxiliary power supply, circuit breaker tripping, fuse break down, over current and overvoltage for power devices | ||||||||
System parameters | Work environment | Ambient temperature: 0℃~40℃ Relative humidity: 30%~90% Altitude: < 1000m (the power drops by 1% with every increase of 100m in altitude, and the maximum height is 4000m) | |||||||
Cooling method | Forced air cooling | ||||||||
Communication interface | RS232 and RS485. Dry contact interface and SNMP card are optional. | ||||||||
Current sharing unevenness for parallel operation | ≤3% | ||||||||
Redundancy | Series or parallel connected hot standby | ||||||||
Resistance to surge | 10/700μS, 5KV 8/20μS, 20KA | ||||||||
IP rating | IP21 | ||||||||
Safety performance | 3000VAC between input/output and ground, leakage current is lower than 3.5mA, and insulation resistance is over 2MΩ (500VDC). | ||||||||
Noise level | 45~50dB | 50~55dB | 55~58dB | 55~60dB | |||||
Size (W×D×H) | 450×600×1200 | 600×720×1520 | 980×800×1800 | ||||||
Weight | 108kg | 146kg | 162kg | 178kg | 239kg | 318kg | 445kg | 498kg |
Three-phase input three-phase output | 80KVA | 100KVA | 120KVA | 160KVA | 200KVA | 250KVA | 300KVA | 400KVA | |
Rated capacity | 80KVA | 100KVA | 120KVA | 160KVA | 200KVA | 250KVA | 300KVA | 400KVA | |
Product type | Low frequency double conversion online UPS | ||||||||
Phase number | Three phase (L N G) | ||||||||
Input power factor | ≥0.85 when with 6-pulse rectifier, ≥0.99 when with 12-pulse rectifier and filter | ||||||||
Rectifier | Nominal input voltage | 380VAC | |||||||
Input voltage range | ±25% | ||||||||
Nominal input frequency | 50Hz±10%, 60Hz±10% | ||||||||
Input harmonic current | <30% for 6-pulse rectifier, <5% for 12-pulse rectifier and filter | ||||||||
Ripple factor | <2% | ||||||||
Soft start | 0~100%, 5 seconds | ||||||||
Charge process | Charge mode | Charge at constant current first, and then at constant voltage. Temperature compensated charging, automatic switch between float charge and equalizing charge, programmable automatic maintenance for charge and discharge at fixed time are also provided. | |||||||
Float charge voltage | 432VDC | ||||||||
Equalizing charge voltage | 464VDC | ||||||||
Temperature compensating voltage | 3mV/℃ (single) | ||||||||
Charge current | 0.1C (Automatically adjusted according to settings of battery capacity) | ||||||||
Charge power | 20% of rated capacity | ||||||||
Battery | Type | Maintenance free lead-acid battery | |||||||
Capacity | Adjustable within 7~999Ah (the capacity range changes with power) | ||||||||
Quantity | 32pcs of 12V-battery or 192pcs of 2V-battery (nominal voltage of 384VDC) | ||||||||
Inverter | Phase number | Three phase N | |||||||
Rated power | Rated capacity × 0.9 | ||||||||
Nominal voltage | 380VAC | ||||||||
Output voltage stability | ±1% for steady load, ±3% for fluctuated load | ||||||||
Frequency stability | 50Hz/60Hz±0.5% (out of synchronization) | ||||||||
Crest factor | >5:1 | ||||||||
Output waveform and harmonic distortion | Sine wave, <3% for linear load, <5% for non-linear load | ||||||||
Dynamic characteristic | Transient voltage <±5% (change from 0% to 100%), recovery time<10ms | ||||||||
Unbalance load voltage | ≤±5% | ||||||||
Overload protection | 115%: normal work, 125%: 60 minutes, 150%: 10 minutes, 200%: 10 seconds | ||||||||
Efficiency | >95% at full load | ||||||||
Bypass | Phase | Three phase N | |||||||
Nominal input voltage | 380VAC | ||||||||
Nominal output voltage | 380VAC | ||||||||
Transfer time | 0ms (static switch) | ||||||||
Protections | Input | Over/under voltage and frequency, phase loss and fault | |||||||
Output | Over current, short circuit, low power factor | ||||||||
Battery | Overcharge, overdischarge | ||||||||
Temperature | High ambient/inverter temperature | ||||||||
Hardware | Abnormal auxiliary power supply, circuit breaker tripping, fuse break down, over current and overvoltage for power devices | ||||||||
System parameters | Economical operation mode | The overall efficiency when running under ECO mode could reach up to 98%. | |||||||
Audible alarm | Audible alarm is available if UPS failure occurs. | ||||||||
Working environment | Ambient temperature: -30℃~50℃ Relative humidity: 30%~90% Altitude: <2000m (the power the power drops by 1% with every increase of 100m in altitude, and the maximum height is 4000m) | ||||||||
Cooling method | Forced air cooling | ||||||||
Communication interface | RS232 and RS485. Dry contact interface and SNMP card are optional. | ||||||||
Redundancy | Series or parallel connected hot standby | ||||||||
Resistance to surge | 10/700μS, 5KV 8/20μS, 20KA | ||||||||
IP rating | IP31 | ||||||||
Safety performance | 3000VAC between input/output and ground, leakage current is lower than 3.5mA, and insulation resistance is over 2MΩ (500VDC). | ||||||||
Noise level | 60~65dB | 65~70dB | |||||||
Size (W×D×H) | 980×800×1800mm | 1380×950×1800mm | 1600×1150×1800mm | ||||||
Weight | 560kg | 850kg | 910kg | 1320kg | 1680kg | 1750kg | 1830kg | 1980kg |