The PS series electrical specialized UPS could be divided into three types, which are single-phase input single-phase output type, three-phase input single-phase output type and three-phase input three-phase output type.
1. Single-Phase Input Single-Phase Output Type
It combines advanced IGBT and high frequency PWM technology together to cut down system noise and power loss, thus guaranteeing that high quality output voltage is delivered under different load conditions. Meanwhile, the state-of-the-art modular design effectively reduces MTTR (mean time to repair), which is very meaningful for maintenance work.
2. Three-Phase Input Single-Phase Output Type
This type makes use of several intelligent CPU and microprocessor-based digital software to realize precise control and adjustment for all kinds of parameters of this electrical specialized UPS, and the sufficient computing power makes our product be in optimum working condition at all times.
3. Three-Phase Input Three-Phase Output Type
This type takes advantage of IGBT and high frequency carrier wave to accurately control different operating parameters, thus providing reliable, high quality AC power for the connected equipment. This product has found a wide range of applications, such as microcomputers, large-scale computers, communication systems, industrial automatic control equipment and many others.
Applications
Our electrical specialized UPS is able to deliver desired performance in many fields, including power plant, power system, stock exchange, office automation control, telecommunication industry, industrial automatic control equipment, radio and television industry, national defense system, petrochemical engineering industry, etc.
Features
1. Our product adopts standard cabinet design for electric power system, and there is no transfer time for the digitally controlled static switch.
2. Advanced online double conversion technology is applied, and input isolation transformer and output isolation transformer are both equipped. Moreover, complete electric isolation is realized between any two of the three which are mains supply, DC power and load end, while various protection functions, including overvoltage, under voltage, over current, short circuit and more, are available for the purpose of safe running.
3. This electrical specialized UPS fits for continuous running when 100% unbalanced load occurs, and the LCD display could reveal data in different languages. In addition, intelligent detection and RS232/485 monitoring are also achieved.
PS2K~PS20K (single-phase input single-phase output type) | ||||||
Model | PS2K | PS3K | PS6K | PS10K | PS15K | PS20K |
Capacity | 2KVA/1.6KW | 3KVA/2.4KW | 6KVA/4.8KW | 10KVA/8KW | 15KVA/12KW | 20KVA/16KW |
AC input voltage | Single phase three wire (L N G), 220V±25% | |||||
AC output voltage | 220V±0.5% | |||||
DC voltage | 220V (110V) | 220V | ||||
DC voltage range | 180V~300V (90V~150V) | 180V~300V | ||||
Noise level | ≤52dB (1m) | ≤60dB (1m) | ||||
Size (W×D×H) | 600×800×2260mm | |||||
Weight (without battery) | 85kg | 110kg | 130kg | 190kg | 200kg | 240kg |
AC input | Frequency | 50Hz/60Hz±10% | ||||
Efficiency | ≥95% | |||||
AC output | Frequency | 50Hz/60Hz±0.05% (when DC supplies power) | ||||
Waveform | Pure sine wave with harmonic distortion of <3% for linear load or <5% for non-linear load | |||||
Dynamic transient range | ≤3% when output 0%~50%~100%, recovery time ≤10ms | |||||
Overload capability | 125%: ≥10 minutes, 150%: ≥10ms | |||||
Crest factor | 5:1 | |||||
Transfer time from AC to DC | 0ms | |||||
Overall efficiency | ≥95% | |||||
Alarm | DC discharge | Low DC voltage: beep every second, DC discharge finished: continuous beep | ||||
Fault | Continuous beep | |||||
System parameter | LCD display | Input/output voltage and frequency, battery voltage, output power (%) | ||||
MTBF (mean time between failures) | 300 thousand hours | |||||
Ambient condition | -10℃~50℃, 0~93% (non-condensing), altitude≤3000m | |||||
Applicable operating system | Novell Netware, Microsoft Windows9X, Windows2000, Windows NT, Windows XP, Linux | |||||
Others | Dustproof and moisture proof design, input/output isolation transformers, lightning and surge protector |
PS6K~PS60K (three-phase input single-phase output type) | ||||||||
Model | PS6K | PS10K | PS15K | PS20K | PS30K | PS40K | PS50K | PS60K |
Capacity | 6KVA/4.8KW | 10KVA/8KW | 15KVA/12KW | 20KVA/16KW | 30KVA/24KW | 40KVA/32KW | 50KVA/40KW | 60KVA/48KW |
AC input voltage | Three phase five wire (L1 L2 L3 N G), 380V±25% | |||||||
AC output voltage | 220V±0.5% | |||||||
DC voltage | 220V (110V) 25%/-18% | 220V 25%/-18% | ||||||
DC voltage range | 180V~300V (90V~150V) | 180V~300V | ||||||
Noise level | ≤60dB (1m) | ≤65dB (1m) | ||||||
Size (W×D×H) | 620×343×1100mm | 600×550×1135mm | 600×800×2260mm | |||||
Weight (without battery) | 140kg | 175kg | 200kg | 250kg | 450kg | 500kg | 600kg | 700kg |
AC input | Frequency | 50Hz/60Hz±10% | ||||||
Efficiency | ≥95% | |||||||
AC output | Frequency | 50Hz/60Hz±0.05% (when DC supplies power) | ||||||
Dynamic transient range | ≤3% when output 0%~50%~100%, recovery time ≤10ms | |||||||
Overload capability | 150% | |||||||
Waveform | Pure sine wave with harmonic distortion of <3% for linear load or <5% for non-linear load | |||||||
Crest factor | 5:1 | |||||||
Transfer time from AC to DC | 0ms | |||||||
Overall efficiency | ≥95% | |||||||
Alarm | DC discharge | Low DC voltage: beep every second, DC discharge finished: continuous beep | ||||||
Fault | Continuous beep | |||||||
System parameter | LCD display | Input/output voltage and frequency, battery voltage, output power (%), temperature | ||||||
MTBF (mean time between failures) | 300 thousand hours | |||||||
Ambient condition | -10℃~50℃, 0~93% (non-condensing), altitude≤3000m | |||||||
Applicable operating system | Novell Netware, Microsoft Windows9X, Windows2000, Windows NT, Windows XP, Linux | |||||||
Others | Dustproof and moisture proof design, input/output isolation transformers, lightning and surge protector, manual bypass switch |
PS6K~PS60K (three-phase input three-phase output type) | ||||||||
Model | PS6K | PS10K | PS15K | PS20K | PS30K | PS40K | PS50K | PS60K |
Capacity | 6KVA/4.8KW | 10KVA/8KW | 15KVA/12KW | 20KVA/16KW | 30KVA/24KW | 40KVA/32KW | 50KVA/40KW | 60KVA/48KW |
AC input voltage | Three phase five wire (L1 L2 L3 N G), 380V±25% | |||||||
AC output voltage | Three phase four wire (L1 L2 L3 N), 380V±1% | |||||||
DC voltage | 220V(110V) 25%/-18% | 220V 25%/-18% | ||||||
Noise level | ≤53dB (1m) | ≤60dB (1m) | ||||||
Size (D×W×H) | 600×800×2260mm | |||||||
Weight (without battery) | 260kg | 280kg | 310kg | 340kg | 490kg | 540kg | 650kg | 720kg |
AC input | Frequency | 50Hz/60Hz±10% | ||||||
Efficiency | ≥95% | |||||||
AC output | Frequency | 50Hz/60Hz±0.05% (when DC supplies power) | ||||||
Unbalanced voltage | ≤1% for balanced load, ≤3% for unbalanced load | |||||||
Overload capability | 125%: ≥10 minutes, 150%: ≥20 seconds | |||||||
Waveform | Pure sine wave with harmonic distortion of <3% for linear load or <5% for non-linear load | |||||||
Crest factor | 5:1 | |||||||
Transfer time from AC to DC | 0ms | |||||||
Overall efficiency | ≥95% | |||||||
Alarm | DC discharge | Low DC voltage: beep every second, DC discharge finished: continuous beep | ||||||
Fault | Continuous beep | |||||||
System parameter | UPS failure | Automatically switched to bypass circuit, and mains supply will provide power | ||||||
LCD display | Input/output voltage and frequency, battery voltage, output power (%), temperature | |||||||
MTBF (mean time between failures) | 300 thousand hours | |||||||
Ambient condition | -10℃~50℃, 0~93% (non-condensing), altitude≤3000m | |||||||
Applicable operating system | Novell Netware, Microsoft Windows9X, Windows2000, Windows NT, Windows XP, Linux | |||||||
Others | Dustproof and moisture proof design, input/output isolation transformers, lightning and surge protector |
PS80K~PS400K (three-phase input three-phase output type) | ||||||||
Model | PS80K | PS100K | PS120K | PS150K | PS200K | PS250K | PS300K | PS400K |
Capacity | 80KVA/64KW | 100KVA/80KW | 120KVA/96KW | 150KVA/120KW | 200KVA/160KW | 250KVA/200KW | 300KVA/ 240KW | 400KVA /320KW |
AC input voltage | Three phase five wire (L1 L2 L3 N G), 380V±25% | |||||||
AC output voltage | Three phase four wire (L1 L2 L3 N), 380V±1% | |||||||
DC voltage | 220V 25%/-18% | |||||||
Noise level | ≤60dB (1m) | ≤65dB (1m) | ||||||
Size (D×W×H) | 600×1000×2260mm 600×800×2260mm | 600×1600×2260mm 600×800×2260mm | ||||||
Weight (without battery) | 800kg | 900kg | 1000kg | 1300kg | 1700kg | 1950kg | 2300kg | 2750kg |
AC input | Frequency | 50Hz/60Hz±10% | ||||||
Efficiency | ≥95% | |||||||
AC output | Frequency | 50Hz/60Hz±0.05% (when DC supplies power) | ||||||
Unbalanced voltage | ≤1% for balanced load, ≤3% for unbalanced load | |||||||
Overload capability | 125%: ≥10 minutes, 150%: ≥20 seconds | |||||||
Waveform | Pure sine wave with harmonic distortion of <3% for linear load or <5% for non-linear load | |||||||
Crest factor | 5:1 | |||||||
Transfer time from AC to DC | 0ms | |||||||
Overall efficiency | ≥95% | |||||||
Alarm | DC discharge | Low DC voltage: beep every second, DC discharge finished: continuous beep | ||||||
Fault | Continuous beep | |||||||
System parameter | UPS failure | Automatically switched to bypass circuit, and mains supply will provide power | ||||||
LCD display | Input/output voltage and frequency, battery voltage, output power (%), temperature | |||||||
MTBF (mean time between failures) | 300 thousand hours | |||||||
Ambient condition | -10℃~50℃, 0~93% (non-condensing), altitude≤3000m | |||||||
Applicable operating system | Novell Netware, Microsoft Windows9X, Windows2000, Windows NT, Windows XP, Linux | |||||||
Others | Dustproof and moisture proof design, input/output isolation transformers, lightning and surge protector |