Home Electrical Specialized UPS

Electrical Specialized UPS

General Introduction
The PS series electrical specialized UPS could be divided into three types, which are single-phase input single-phase output type, three-phase input single-phase output type and three-phase input three-phase output type.


1. Single-Phase Input Single-Phase Output Type
It combines advanced IGBT and high frequency PWM technology together to cut down system noise and power loss, thus guaranteeing that high quality output voltage is delivered under different load conditions. Meanwhile, the state-of-the-art modular design effectively reduces MTTR (mean time to repair), which is very meaningful for maintenance work.


2. Three-Phase Input Single-Phase Output Type
This type makes use of several intelligent CPU and microprocessor-based digital software to realize precise control and adjustment for all kinds of parameters of this electrical specialized UPS, and the sufficient computing power makes our product be in optimum working condition at all times.


3. Three-Phase Input Three-Phase Output Type
This type takes advantage of IGBT and high frequency carrier wave to accurately control different operating parameters, thus providing reliable, high quality AC power for the connected equipment. This product has found a wide range of applications, such as microcomputers, large-scale computers, communication systems, industrial automatic control equipment and many others.


Applications
Our electrical specialized UPS is able to deliver desired performance in many fields, including power plant, power system, stock exchange, office automation control, telecommunication industry, industrial automatic control equipment, radio and television industry, national defense system, petrochemical engineering industry, etc.


Features
1. Our product adopts standard cabinet design for electric power system, and there is no transfer time for the digitally controlled static switch.
2. Advanced online double conversion technology is applied, and input isolation transformer and output isolation transformer are both equipped. Moreover, complete electric isolation is realized between any two of the three which are mains supply, DC power and load end, while various protection functions, including overvoltage, under voltage, over current, short circuit and more, are available for the purpose of safe running.
3. This electrical specialized UPS fits for continuous running when 100% unbalanced load occurs, and the LCD display could reveal data in different languages. In addition, intelligent detection and RS232/485 monitoring are also achieved.

Electrical Specialized UPS




Technical Parameters
PS2K~PS20K (single-phase input single-phase output type)
Model PS2K PS3K PS6K PS10K PS15K PS20K
Capacity 2KVA/1.6KW 3KVA/2.4KW 6KVA/4.8KW 10KVA/8KW 15KVA/12KW 20KVA/16KW
AC input voltage Single phase three wire (L N G), 220V±25%
AC output voltage 220V±0.5%
DC voltage 220V (110V) 220V
DC voltage range 180V~300V (90V~150V) 180V~300V
Noise level ≤52dB (1m) ≤60dB (1m)
Size (W×D×H) 600×800×2260mm
Weight (without battery) 85kg 110kg 130kg 190kg 200kg 240kg
AC input Frequency 50Hz/60Hz±10%
Efficiency ≥95%
AC output Frequency 50Hz/60Hz±0.05% (when DC supplies power)
Waveform Pure sine wave with harmonic distortion of <3% for linear load or <5% for non-linear load
Dynamic transient range ≤3% when output 0%~50%~100%, recovery time ≤10ms
Overload capability 125%: ≥10 minutes, 150%: ≥10ms
Crest factor 5:1
Transfer time from AC to DC 0ms
Overall efficiency ≥95%
Alarm DC discharge Low DC voltage: beep every second, DC discharge finished: continuous beep
Fault Continuous beep
System parameter LCD display Input/output voltage and frequency, battery voltage, output power (%)
MTBF (mean time between failures) 300 thousand hours
Ambient condition -10℃~50℃, 0~93% (non-condensing), altitude≤3000m
Applicable operating system Novell Netware, Microsoft Windows9X, Windows2000, Windows NT, Windows XP, Linux
Others Dustproof and moisture proof design, input/output isolation transformers, lightning and surge protector




Table 2
PS6K~PS60K (three-phase input single-phase output type)
Model PS6K PS10K PS15K PS20K PS30K PS40K PS50K PS60K
Capacity 6KVA/4.8KW 10KVA/8KW 15KVA/12KW 20KVA/16KW 30KVA/24KW 40KVA/32KW 50KVA/40KW 60KVA/48KW
AC input voltage Three phase five wire (L1 L2 L3 N G), 380V±25%
AC output voltage 220V±0.5%
DC voltage 220V (110V) 25%/-18% 220V 25%/-18%
DC voltage range 180V~300V (90V~150V) 180V~300V
Noise level ≤60dB (1m) ≤65dB (1m)
Size (W×D×H) 620×343×1100mm 600×550×1135mm 600×800×2260mm
Weight (without battery) 140kg 175kg 200kg 250kg 450kg 500kg 600kg 700kg
AC input Frequency 50Hz/60Hz±10%
Efficiency ≥95%
AC output Frequency 50Hz/60Hz±0.05% (when DC supplies power)
Dynamic transient range ≤3% when output 0%~50%~100%, recovery time ≤10ms
Overload capability 150%
Waveform Pure sine wave with harmonic distortion of <3% for linear load or <5% for non-linear load
Crest factor 5:1
Transfer time from AC to DC 0ms
Overall efficiency ≥95%
Alarm DC discharge Low DC voltage: beep every second, DC discharge finished: continuous beep
Fault Continuous beep
System parameter LCD display Input/output voltage and frequency, battery voltage, output power (%), temperature
MTBF (mean time between failures) 300 thousand hours
Ambient condition -10℃~50℃, 0~93% (non-condensing), altitude≤3000m
Applicable operating system Novell Netware, Microsoft Windows9X, Windows2000, Windows NT, Windows XP, Linux
Others Dustproof and moisture proof design, input/output isolation transformers, lightning and surge protector, manual bypass switch


Table 3
PS6K~PS60K (three-phase input three-phase output type)
Model PS6K PS10K PS15K PS20K PS30K PS40K PS50K PS60K
Capacity 6KVA/4.8KW 10KVA/8KW 15KVA/12KW 20KVA/16KW 30KVA/24KW 40KVA/32KW 50KVA/40KW 60KVA/48KW
AC input voltage Three phase five wire (L1 L2 L3 N G), 380V±25%
AC output voltage Three phase four wire (L1 L2 L3 N), 380V±1%
DC voltage 220V(110V) 25%/-18% 220V 25%/-18%
Noise level ≤53dB (1m) ≤60dB (1m)
Size (D×W×H) 600×800×2260mm
Weight (without battery) 260kg 280kg 310kg 340kg 490kg 540kg 650kg 720kg
AC input Frequency 50Hz/60Hz±10%
Efficiency ≥95%
AC output Frequency 50Hz/60Hz±0.05% (when DC supplies power)
Unbalanced voltage ≤1% for balanced load, ≤3% for unbalanced load
Overload capability 125%: ≥10 minutes, 150%: ≥20 seconds
Waveform Pure sine wave with harmonic distortion of <3% for linear load or <5% for non-linear load
Crest factor 5:1
Transfer time from AC to DC 0ms
Overall efficiency ≥95%
Alarm DC discharge Low DC voltage: beep every second, DC discharge finished: continuous beep
Fault Continuous beep
System parameter UPS failure Automatically switched to bypass circuit, and mains supply will provide power
LCD display Input/output voltage and frequency, battery voltage, output power (%), temperature
MTBF (mean time between failures) 300 thousand hours
Ambient condition -10℃~50℃, 0~93% (non-condensing), altitude≤3000m
Applicable operating system Novell Netware, Microsoft Windows9X, Windows2000, Windows NT, Windows XP, Linux
Others Dustproof and moisture proof design, input/output isolation transformers, lightning and surge protector




Table 4
PS80K~PS400K (three-phase input three-phase output type)
Model PS80K PS100K PS120K PS150K PS200K PS250K PS300K PS400K
Capacity 80KVA/64KW 100KVA/80KW 120KVA/96KW 150KVA/120KW 200KVA/160KW 250KVA/200KW 300KVA/ 240KW 400KVA /320KW
AC input voltage Three phase five wire (L1 L2 L3 N G), 380V±25%
AC output voltage Three phase four wire (L1 L2 L3 N), 380V±1%
DC voltage 220V 25%/-18%
Noise level ≤60dB (1m) ≤65dB (1m)
Size (D×W×H) 600×1000×2260mm 600×800×2260mm 600×1600×2260mm 600×800×2260mm
Weight (without battery) 800kg 900kg 1000kg 1300kg 1700kg 1950kg 2300kg 2750kg
AC input Frequency 50Hz/60Hz±10%
Efficiency ≥95%
AC output Frequency 50Hz/60Hz±0.05% (when DC supplies power)
Unbalanced voltage ≤1% for balanced load, ≤3% for unbalanced load
Overload capability 125%: ≥10 minutes, 150%: ≥20 seconds
Waveform Pure sine wave with harmonic distortion of <3% for linear load or <5% for non-linear load
Crest factor 5:1
Transfer time from AC to DC 0ms
Overall efficiency ≥95%
Alarm DC discharge Low DC voltage: beep every second, DC discharge finished: continuous beep
Fault Continuous beep
System parameter UPS failure Automatically switched to bypass circuit, and mains supply will provide power
LCD display Input/output voltage and frequency, battery voltage, output power (%), temperature
MTBF (mean time between failures) 300 thousand hours
Ambient condition -10℃~50℃, 0~93% (non-condensing), altitude≤3000m
Applicable operating system Novell Netware, Microsoft Windows9X, Windows2000, Windows NT, Windows XP, Linux
Others Dustproof and moisture proof design, input/output isolation transformers, lightning and surge protector



Related Names
Emergency Power Source Manufacturer | Network UPS Tool | Electric Power System Component