UL1011PVC Insulated Wire
1
Suitable for the internal wiring of ordinary electrical and electronicequipment, the UL1011 PVC insulated wire is constructed of single or strandedbare or tinned copper conductor and PVC insulation. With the rated voltage of 600Vand the rated temperature of 80 ℃,the product meets the standards of UL758 and UL1581, and the registrationnumber is E310859.
Structure
2
,:
Copper Conductor
PVC PVC Insulation
Type of conductor | Conductor | Diameter | Insulation | Max. conductor resistance | Min. insulation resistance | Voltage resistance | Standard length | ||
Wire gauge | Number/diameter | Nominal thickness | Nominal outer diameter | ||||||
AWG | NO./mm | mm | mm | mm | Ω/km | MΩ/Km | V | Ft (m) | |
Stranded conductors | 30 | 7/0.10 | 0.3 | 0.76 | 1.88 | 354.24 | 15 | 2000 | 2000(610) |
28 | 7/0.127 | 0.38 | 0.76 | 1.96 | 223.75 | ||||
26 | 7/0.16 | 0.48 | 0.76 | 2.06 | 139.73 | ||||
24 | 11/0.16 | 0.61 | 0.76 | 2.19 | 93.3 | ||||
22 | 17/0.16 | 0.76 | 0.76 | 2.35 | 55 | ||||
20 | 26/0.16 | 0.94 | 0.76 | 2.5 | 34.6 | ||||
18 | 41/0.16 | 1.18 | 0.76 | 2.76 | 21.8 | 1000(305) | |||
16 | 26/0.254 | 1.49 | 0.76 | 3.05 | 13.7 | ||||
14 | 41/0.254 | 1.88 | 0.76 | 3.45 | 8.62 | ||||
12 | 65/0.254 | 2.37 | 0.76 | 4.00 | 5.43 | ||||
10 | 9/0.37 | 3.38 | 0.76 | 5.00 | 3.41 | ||||
8 | 168/0.254 | 4.31 | 1.15 | 6.60 | 2.16 | ||||
6 | 124/0.37 | 5.43 | 1.52 | 8.5 | 1.39 | 328(100) | |||
4 | 196/0.37 | 6.78 | 1.52 | 9.8 | 0.88 | ||||
2 | 312/0.37 | 9.04 | 1.52 | 12.1 | 0.55 | 164(50) | |||
1 | 824/0.254 | 9.8 | 2.05 | 13.7 | 0.44 | ||||
1/0 |
| 10.86 | 2.05 | 15 | 0.35 | ||||
2/0 | 616/0.37 | 12.3 | 2.05 | 16.8 | 0.28 | ||||
3/0 | 776/0.37 | 13.8 | 2.05 | 17.8 | 0.22 | ||||
4/0 | 980/0.37 | 15.4 | 2.05 | 19.6 | 0.17 | ||||
Single conductor | 28 | 1/0.32 | 0.32 | 0.76 | 1.9 | 227.39 |
| 2000(610) | |
26 | 1/0.404 | 0.404 | 0.76 | 1.98 | 142.79 | ||||
24 | 1/0.511 | 0.511 | 0.76 | 2.09 | 89.39 | ||||
22 | 1/0.643 | 0.643 | 0.76 | 2.22 | 54.3 | ||||
20 | 1/0.813 | 0.813 | 0.76 | 2.39 | 33.9 | ||||
18 | 1/1.024 | 1.024 | 0.76 | 2.6 | 21.4 | ||||
16 | 1/1.29 | 1.29 | 0.76 | 2.87 | 13.5 |
We provide twotypes of the UL1011 PVC insulated wire single conductor type and stranded conductors type. The insulationlayer of the single conductor type product has a nominal thickness of 0.76mm, which is easy to peel and cut off.Our products have passed VW-1 and FT1 vertical flame test and have resistanceto acid and oil, mould proofing, environment protection and other features.When exposed to oil environment, the temperature should not exceed 60℃ or 80℃.