F8 Multi-Parameter Patient Monitor
The F8 multi-parameter patient monitor with the standard configuration of 3-lead or 5-lead ECG/HR, RESP, TEMP, SpO2/PR, and NIBP. Optional parameters include 2-IBP, ETCO2, and the depth of anesthesia monitoring module. Optional accessories include VGA, printer, wall-mount, and a portable trolley. The 12.1 inch color TFT LCD screen supports up to 11 different waveforms on a single screen and implements a multi-language interface that accommodates up to 14 languages. The robust display modes include large font, NIBP trend, trend table, full lead ECG, and Oxy CRG. A fully featured alarm system includes visual on-display, integrated alarm light, and a personated voice reminding alarm. The multi-parameter patient monitor is capable of producing a drug calculation and titration table, real time S-T segment analysis, pace detection, as well as Arrhythmia analysis. With a massive storage that can accommodate 720 hours of patient data, 1000 NIBP records, and 500 individual alarm events, the monitor is suitable for extensive monitoring of adult, pediatric, and neonatal patients. This unit is isolated against defibrillation and can achieve wired or wireless connection with a central station system.
Configurations
● Standard ○ Optional - Unavailable | ECG | SpO2/PR | 2- TEMP | NIBP | RESP | 2-IBP | Nellcor SpO2 | VGA | Printer 50mm | Wall-mount /Trolley | Central Station | Touch Screen | ETCO2 Mainstream/ Side-stream/ Micro-stream | Multigas / O2 |
F8 | ● | ● | ● | ● | ● | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ | ○ |
Physical Specifications
Dimension and weight | |
Dimension | 340mm (W)*280mm(H)*130mm(D) |
Weight | standard configuration: 4 kg |
Operation environment | |
Power requirements | AC 90-300V, 50/60HZ, 60W |
Power | 90VA |
Temperature | 5-40℃ |
Humidity | 30-93% non-condensing |
Safety | Meet the requirements of IEC60601 series |
Patient range | Adult, neonate and pediatric patients |
Performance Specification of the F8 Multi-Parameter Patient Monitor
Display | 12.1 inch (800 x 600 pixel) color TFT LCD rolling and refreshing waveform display |
Display mode | Standard, large font, NIBP trend, trend table, full lead ECG, Oxy CRG. |
Interface | Parameter cable interfaceAC power input socketNetwork interface External VGA interface for connection of alternate display |
Battery | Internal rechargeable lead-acid cell, 12V/2.0AH |
Alarm indicator | Visual on-display and integrated alarm light Audible alarm and personated voice reminding alarm |
Data storage | 720 hours monitoring data10000NIBP records storage 500 alarm events. |
Printer | Built-in 50mm thermal printer (option), 3 traces, print speed 25mm/s & 50mm/s print width:50mm |
Net working | Support connection to central monitoring station through LAN (TCP/IP) or wireless connection |
ECG | |
Leads type | 3(option)/5-lead : I, II, III, aVR , aVL , aVF , V |
Sweep speed | 12.5mm /s, 25mm/s,50mm/s |
Gain selection | ×0.25 , ×0.5, ×1, ×2 |
ECG waveform | 3 channels |
Operation mode | Diagnostic, monitor, surgery |
Heart rate range | 15 -350bpm |
Accuracy | 1bpm or ±1% whichever is great |
Alarm | |
ST/ arrhythmia | Real time S-T segment detection, pace detection and arrhythmia analysis |
Protection | Against electrosurgical interference and defibrillation |
Respiration (RESP)
Method | Thoracic impedance |
Operation mode | Auto/manual |
Measurement range | Adult: 0-120BrPM; neonatal /pediatric: 0-150BrPM |
Apnea alarm | Yes |
Alarm | Audible and visual alarm, personated voice reminding alarm and alarm events recallable |
NIBP
Method | Automatic oscillometric |
Operation mode | Manual/Automatic/STAT |
Auto measure time | Adjustable |
Measurement unit | mmHg / kPa selectable |
Test interval | 1-480 minutes |
Measurement range | Adult: 0-300 mmHg ; Child: 0-240 mmHg ; Infant: 0-150 mmHg |
Over-pressure protection | Double safety protection |
Accuracy of blood pressure measurement | The mean error shall be less than±5mmHgthe standard deviation shall be less than 8mmHG |
Resolution | 1 mmHg |
Accuracy | ±3bpm(non-motion) ±5bpm(motion ) |
SpO2
Measurement range | 0%-100% | |
Resolution | 1% | |
Accuracy | ±2% (70-100%, adult/pediatric, non-motion ) ±3% (70-100%, neonate, non-motion ) ±3% (70-100%, adult/pediatric/neonate, motion ) 0-69% unspecified | |
Alarm range | 1-100% | |
Pulse rate | Pulse range: | 0-350bpm |
Temperature (TEMP)
TEMP range | 0-50℃ |
Resolution | 0.1 ℃ |
Accuracy | ±0.1℃ (excluding the sensor) |
Channel | Dual-channel. provide T1;T2; △ T |
IBP
Measurement range | -50-360mmHg | |
Channel | 2 channels | |
Pressure transducer | Sensitive :5u V/V mmHg Impedance range :300-3000 Ω | |
Pressure names | ART ,PA ,CVP,RAP,LAP,ICP,P1,P2 | |
Alarm range | -10-300 mmHg | |
PR from IBP | Range & Accuracy: | 25-200bpm ±1bpm or ±1bpm which is greater 201-350bpm ±2% |
Resolution | 1bpm |
Depth of Anesthesia
EEG sensitivity | /- 475μV |
Noise | < 2uVp-p (1-150 Hz) |
CMRR | > 100 dB |
Input impedance | > 50mohm |
Sample rate | 1024 samples/s, 16 bits |
Index and display update | IoC 0-99, filter 1-47 Hz, 1 sec. display update |
EEG waveform | ± 500 µV scaleable, filter 1–30 Hz, 3 sec. window length. |
ESR | 0-100% |
EMG 0-100 arbitrary unit | Curve and bar |
Index trend | 5 min and 60 min |
Digital output | Wireless BT interface (RFCOMM). 10 meters range |
Alarms | IoC high and low user selectable limits |
Artifact rejection | Automatic: user can disable. |
Sensor impedance range | 0 - 14kohm |
EtCO2 (Main-stream / Side-stream / Micro-stream CO2)
Measurement range | 0-150mmHg |
Accuracy | ±2mmHg(0-40mmHg)±5% of reading(41-76mmHg)±10% of reading (77-99mmHg) |
Resolution | 1mmHg |
Sampling rate | 70m 1/min 100m1/min |
Sampling rate accuracy | 0.15 or 15m1/min |
Start-up time | 30 Sec. the module enters the warming up status after the start up.1 minute later, it enters the ready-to-measure status. |
Respiration rate | 3-180 rpm |
Respiration rate accuracy | ±2BrPM (0-70BrPM) ±5BrPM (>70BrPM) |
Response time | When measured with a neonatal water trap and a 2.5 m-long neonatal sampling line: < 3.5 s @ 100 ml/min <4 s @ 70 ml/min When measured with an adult water trap and a 2.5 m-long adult sampling line: <5.5 s @ 100 ml/min <7 s @ 70 ml/min |
Delay time | When measured with a neonatal water trap and a 2.5m-long neonatal sampling line: <3 s @ 100 ml/min <3.5 s @ 70 ml/minWhen measured with an adult water trap and a 2.5m-long adult sampling line: <5 s @ 100 ml/min <6.5 s @ 70 ml/min |
Multi-Gas/O2
Method | Infrared absorption |
Gas sorts | CO2, N2O, Des, Iso, Enf, Sev, Hal, O2,(Optional paramagnetic sensor) |
Measurement range | CO2: 0~30% N2O : 0~105% O2, :0~105%Enf , Iso , Hal: 0~30% Sev : 0~30%Des:0~30% |
Data output | Fi and ET values |
Respiration rate | ±1BrPM(2~60BrPM)61~100BrPM (unspecified) |
Other | Up to 4 waveforms displayedAgent mixture detection MAC value displayed |