This photovoltaic AC connector is used for the connection of micro inverters and the bus cable. The use of high-quality engineering plastic PPO/PC and the excellent sealing performance ensure the reliability and performance. This PV connector also features an excellent resistance to UV light, salt spray, high temperatures, vibration and shock.
BC05 Electrode cores: three-core Main line rated voltage and current: 300V 30A Branch line rated voltage and current: 300V 8A Waterproof Rating: IP68(1.5m,24h) Flammability Rating: UL94-V0 Insulation resistance: >5MΩ Insulation voltage: 1500V AC (10mA,1Min) Technical ParametersGeneral
Pin Number | 2P PE |
Main Line Rated Current | 32A (Use 10AWG/6mm² copper cable) |
Main Line Rated Voltage | 300V |
Branch Line Rated Current | 12A (Use 16AWG/1.5mm² copper cable) |
Branch Line Rated Voltage | 300V |
Contact Resistance | ≤5mΩ |
Power Frequency Withstand Voltage | 1500V AC |
Over-voltage Category | Ⅲ |
Closure Pollution Degree | 2(mated) |
Protection Class | IP68(1.5m, 24hour) |
Withdraw Force | 50~100N |
Flammability Rating | UL94-V0 |
Rated Temperature | -40℃~ 85℃ |
Connection Data
Applicable Cable Specification | Main Line: 14/12/10AWG; branch: 16/18AWG |
Applicable Cable Outer Diameter | Main Line: 10~13mm; branch: 7~9.5mm |
Locking System | Snap |
Main Line Connection | Screw Pressing |
Branch Line Connection | Crimping |
Materia
Housing Material | PPE |
Terminal Material | Copper zinc alloy |
Terminal Surface Treatment | Main line: tin-plated; branch line: gold plated |
Sealing Material | Silicon rubber |
Standards
PPP 59015A:2013 | TUV test standard |
ANSI/UL6703-2017 | CSA test standard |
RoHS Compliant | Yes |
Dimensions
Length | 150mm |
Width | 40mm |
Height | 110mm |