2-5mA Wound Primary CurrentTransformer
Product Structure
:()
Due to the epoxy resin wrap cover packaging, the 5-5mA wound primarycurrent transformer sports high insulation strength. This product has passedthe RoHS and CE certifications. It has high consistency and wide linear range.This product is designed in a simple structure which can be easily mounted onPCB.
Specification
Model | DCR (ohm) | Rated Input(MAX) (A) | Rated Output (mA) | Suggested Load Resistance (ohm) | Accuracy | Phase Angle Shift | ||||||
WCT102CC | ≤ 60 | 5 (20) | 5 | ≤ 10 | 0.1 | 25’ | ||||||
WCT202CC | ≤ 200 | 5 (25) | 2.5 | ≤ 50 | 0.1 | 25’ | ||||||
WCT252CC | ≤ 320 | 5 (25) | 2 | ≤ 50 | 0.1 | 25’ | ||||||
Thereare three models for this wound primary current transformer. With differentconversion ratio, they can convert the same 5A rated input current into respectively 5mA, 2.5mA,and 2mA current. Strong current conversion ability brings large coilresistance. The accuracy of the ratio in current conversion is within 0.1, andthe error of AC phase is less than 25’,so this product can work stably in circuit.
Performance Curve
:1、2、3()