Features 7.6kW to 11.4kW range
A variety of lithium batteries and lead-acid batteries can be connected with the hybrid inverter.
Quick and easy wiring
IP65 design, natural cooling, low noise due to no external fan design
Battery reverse polarity protection, the charge and discharge controlled by intelligent software greatly improve the battery life.
Input and output lightning protection
Arc fault detection in PV inverter
Discharge at full power and disconnect the charger automatically when the battery has been fully charged.
Off Grid full power output
Allows for transient overload operation under greater than 1.5 times the rated power of the inverter
Soft starter, with air conditioning, water pump and other loads.
Insulation detection, battery leakage detection, ground fault detection, anti-islanding protection to prevent electric shock.
Maximum efficiency up to 98.2%
With 4 independent MPPT (maximum power point tracker) design, the light energy in different directions can be fully utilized.
Distributed virtual power station management system
Remote monitoring controlled by computers and mobile phones Application Examples Villa Communications base station Nomadic area Farm Household Back-up power How it works?
Technical Parameters
Model | R7K6H1NA | R9KH1NA | R10KH1NA | R11K4H1NA |
PV Input |
PV Input Power | 10kW | 11.7kw | 13kw | 14.82KW |
MPPT Number | 4 |
PV Voltage Range | 150 - 500V |
Max PV Input Voltage | 500V |
Each MPPT Input Current | 13A | 13A | 14A | 14A |
AC Output (On Grid) |
Rated AC Output | 120/240V 7.6KW | 120/240V 9KW | 120/240V 10KW | 120/240V 11.4W |
AC Output Voltage | 110-120/220-240V split phase, 1Ø, 230 1 phase |
AC Output Frequency | 50/60Hz (45 to 54.9Hz / 55 to 65Hz) |
Max Output Current | 32A RMS | 37.5A | 41.7A | 47.5A |
AC Reverse Charging | Yes |
Power Factor | 0.8leading…0.8lagging |
THDI | |
Backup AC Output |
Rated Backup Output Power | 7.6W | 9KW | 10KW | 11.4KW |
Max. Backup Output power | 9.5KVA 60S/11.4KVA 1S | 11.25KVA 60S/13.5KVA 1S | 12.5KVA 60S/15KVA 1S | 14.25KVA 60S/17.1KVA 1S |
Backup AC Output voltage | 110-120/220-240 split phase, 1Ø, 230 1 phase |
AC Frequency | 50/60Hz |
Output THDI | |
Battery |
Max. Charge & Discharge current | 80 A / 80 A | 62.5A/62.5A | 69.5A/69.5A | 79A/79A |
Battery Voltage Range | 96V~336V | 150V~336V | 150V~336V | 150V~336V |
Battery Capacity Range | 6.6 to 66 kWh |
Battery type | Lithium/Lead-acid |
Efficiency |
Max efficiency | ≥98.2% |
CEC efficiency | ≥97.2% |
Protection |
Complete Protection | Ground protection; Pull arc protection; Anti-islanding protection; DC disconnect detection; Battery reverse protection; Battery charge and discharge protection; Insulation testing; GFCI; DC&AC anti-thunder; Overvoltage and under-voltage protections; AC&DC over-current protection; AC short-circuit current protection; Overheating protection |
General Data |
AC and Backup Output Conduit Size | 25.4 mm |
PV Input Conduit Size | 25.4 mm |
Battery Input Conduit size | 34.5mm |
Operation Temperature Range | -25 ~ 60°C |
Environment Humidity | 0-95% |
Altitude | 0~4000M(Derating when over 2000m) |
IP Grade | IP65 |
Weight | 30kg |
Dimension (W x H x D) | 530x 660 x 200mm |
Cooling | Natural cooling |
Noise Emission(dB) | | | | |
Display | LCD |
Communication | Modbus, RS485, WIFI, 4G |
Self-Consumption at Night | |
No Transformer | YES |
Safety | UL1741SA all options, UL1699B, CSA 22.2 |
EMC | FCC Part 15 Class B |