Home RKH1NA Series Single-Phase Hybrid Inverter

RKH1NA Series Single-Phase Hybrid Inverter

Features
7.6kW to 11.4kW range
A variety of lithium batteries and lead-acid batteries can be connected with the hybrid inverter.
Quick and easy wiring
IP65 design, natural cooling, low noise due to no external fan design
Battery reverse polarity protection, the charge and discharge controlled by intelligent software greatly improve the battery life.
Input and output lightning protection
Arc fault detection in PV inverter
Discharge at full power and disconnect the charger automatically when the battery has been fully charged.
Off Grid full power output
Allows for transient overload operation under greater than 1.5 times the rated power of the inverter
Soft starter, with air conditioning, water pump and other loads.
Insulation detection, battery leakage detection, ground fault detection, anti-islanding protection to prevent electric shock.
Maximum efficiency up to 98.2%
With 4 independent MPPT (maximum power point tracker) design, the light energy in different directions can be fully utilized.
Distributed virtual power station management system
Remote monitoring controlled by computers and mobile phones Application Examples Villa Communications base station Nomadic area Farm Household Back-up power How it works?
Technical Parameters
Model R7K6H1NA R9KH1NA R10KH1NA R11K4H1NA
PV Input
PV Input Power 10kW 11.7kw 13kw 14.82KW
MPPT Number 4
PV Voltage Range 150 - 500V
Max PV Input Voltage 500V
Each MPPT Input Current 13A 13A 14A 14A
AC Output (On Grid)
Rated AC Output 120/240V 7.6KW 120/240V 9KW 120/240V 10KW 120/240V 11.4W
AC Output Voltage 110-120/220-240V split phase, 1Ø, 230 1 phase
AC Output Frequency 50/60Hz (45 to 54.9Hz / 55 to 65Hz)
Max Output Current 32A RMS 37.5A 41.7A 47.5A
AC Reverse Charging Yes
Power Factor 0.8leading…0.8lagging
THDI
Backup AC Output
Rated Backup Output Power 7.6W 9KW 10KW 11.4KW
Max. Backup Output power 9.5KVA 60S/11.4KVA 1S 11.25KVA 60S/13.5KVA 1S 12.5KVA 60S/15KVA 1S 14.25KVA 60S/17.1KVA 1S
Backup AC Output voltage 110-120/220-240 split phase, 1Ø, 230 1 phase
AC Frequency 50/60Hz
Output THDI
Battery
Max. Charge & Discharge current 80 A / 80 A 62.5A/62.5A 69.5A/69.5A 79A/79A
Battery Voltage Range 96V~336V 150V~336V 150V~336V 150V~336V
Battery Capacity Range 6.6 to 66 kWh
Battery type Lithium/Lead-acid
Efficiency
Max efficiency ≥98.2%
CEC efficiency ≥97.2%
Protection
Complete Protection Ground protection; Pull arc protection; Anti-islanding protection; DC disconnect detection; Battery reverse protection; Battery charge and discharge protection; Insulation testing; GFCI; DC&AC anti-thunder; Overvoltage and under-voltage protections; AC&DC over-current protection; AC short-circuit current protection; Overheating protection
General Data
AC and Backup Output Conduit Size 25.4 mm
PV Input Conduit Size 25.4 mm
Battery Input Conduit size 34.5mm
Operation Temperature Range -25 ~ 60°C
Environment Humidity 0-95%
Altitude 0~4000M(Derating when over 2000m)
IP Grade IP65
Weight 30kg
Dimension (W x H x D) 530x 660 x 200mm
Cooling Natural cooling
Noise Emission(dB)
Display LCD
Communication Modbus, RS485, WIFI, 4G
Self-Consumption at Night
No Transformer YES
Safety UL1741SA all options, UL1699B, CSA 22.2
EMC FCC Part 15 Class B