Fiber Count | Cable Size (mm) | Cable Weight (kg/km) | Min. Bending Radius(mm) | Max. Tensile load(N) | Max/ Crush Load(N/100mm) | |||
Static | Dynamic | Short-term | Long-term | Short-term | Long-term | |||
2~30 | 10.0 | 120 | 10D | 20D | 1500 | 600 | 1000 | 300 |
32~36 | 10.5 | 138 | 10D | 20D | 1500 | 600 | 1000 | 300 |
38~60 | 11.3 | 151 | 10D | 20D | 1500 | 600 | 1000 | 300 |
62~72 | 12.0 | 184 | 10D | 20D | 1500 | 600 | 1000 | 300 |
72~96 | 13.8 | 226 | 10D | 20D | 1500 | 600 | 1000 | 300 |
98~120 | 15.4 | 270 | 10D | 20D | 1500 | 600 | 1000 | 300 |
120~144 | 17.0 | 315 | 10D | 20D | 1500 | 600 | 1000 | 300 |
Operating Temperature | -40~70℃ |
Notes: This data-sheet can only be a reference, but not a supplement to the contract. Please contact our sales people for more detailed information.
Characteristics of the Fiber-G.652DItem | Specification | Item | Specification |
Fiber type | Single Mode | PMD | £0.2 ps/km1/2 |
Fiber Material | Doped Silica | Mode field Diameter @ 1310 nm | (8.6~9.5)±0.6 um |
Attenuation Coefficient @ 1310 nm @ 1383 nm @ 1550 nm @ 1625 nm | £ 0.35 dB/km £ 0.35 dB/km £ 0.21 dB/km £ 0.30 dB/km | Chromatic Dispersion @ 1288 ~ 1339 nm @ 1271 ~ 1360 nm @ 1550 nm @ 1625 nm | £3.5 ps/(nm. km) £5.3 ps/(nm. km) £18 ps/(nm. km) £22 ps/(nm. km) |
Point Discontinuity | £ 0.05 dB | Core / Clad Concentricity Error | £ 0.6 um |
Cable Cut-off Wavelength | £ 1260 nm | Cladding Diameter | 125.0 ± 1 um |
Zero-dispersion Wavelength | 1300 ~ 1324 nm | Zero-dispersion Slope | £ 0.092 ps/(nm2.km) |
Primary Coating Diameter | 245 ± 10 um | Temperature Dependence 0oC~ 70oC @ 1310 & 1550nm | £ 0.1 dB/km |
Proof test Level | 100 kpsi (=0.69 Gpa), 1% |
* PMDQ is a link of 20 cable sections (M) and a probability level of 0.01% (Q).