Features
Due to the strong anti-interference ability, the ultrasonic level sensor can be used for liquid level measurement in harsh environments.
Built-in temperature sensitive device ensures a real-time temperature automatic compensation function.
A variety of output types are available to meet different industrial site interface requirements.
The minimum blind zone is 10mm.
Applications
Tap water, sewage treatment liquid level, oil drum oil level detection
Food processing liquid level detection
Liquid level detection of collecting wells and biochemical pools
Liquid level measurement of various slurries
Technical Parameters
Model | LUT-101 With display | LUT-102 (without display) |
Measuring Range | 1m, 2m |
Measurement Dead Zone | ≤0.06~0,15m (depending on range) |
Emission Angle (Full Angle) | Less than 6° |
Precision | ±0.1%(±1mm or ±1.5mm) |
Resolution | 1mm |
Powered Supply | DC12—24V Power consumption: |
Output signal | Current: 4~20mA, 0~20 mA Voltage: 0~5V, 0~10V Digital: RS485(Modbus) Switch output: three-way NPN |
Connection Method | M30*1.5 |
Protection Class | IP65 |
Working Temperature | -10℃~50℃ |
Working Pressure | 0.8MPa |
Temperature Compensation | Full range automatic |
Storage Humidity | ≤80%RH, no condensation |