Anaeston 3000 Anesthetic Machine
Product Overview
Anaeston 3000 anestheticmachine provides an affordable and flexible anesthesia solution for now and thefuture. Our customers can start with routine application. The anestheticmachine is upgradeable to better meet customers’ anesthetic requirements.Modern anesthetic workstation expansion is also feasible to greatly improve theworkflow and cut down the operating cost.
Applications
Anaeston 3000anesthetic machines can be used for inhalationalanesthesia delivery and management for adult, pediatric and neonatal patients.
Features
1. The anestheticmachine offers electronic PEEP function.
2. It has automatic tidal volume compensation,except Anaeston 3000C.
3. It provides a high-precision output as low as 20ml.
4. The anestheticmachine uses autoclavable and latex free components.
5. It can be easily maintained and cleaned without specialized tools.
6. It is CE certified, giving users peace of mind.
Specifications of Anaeston 3000 Anesthetic Machine
Model | Anaeston 3000P | Anaeston 3000PS | Anaeston 3000C |
Dimension | 810x810x1360 mm (WxDxH) | 810x810x1360 mm (WxDxH) | 810x634x1360 mm (WxDxH) |
Weight | 96kg | 96kg | 70kg |
Vaporizer | 1 (secondary is optional) | 1 (secondary is optional) | 1 (secondary is optional) |
Anesthetic type | Halothane, Enflurane, Isoflurane, Sevoflurane, Desflurane | Halothane, Enflurane, Isoflurane, Sevoflurane, Desflurane | Halothane, Enflurane, Isoflurane, Sevoflurane, Desflurane |
Gas supply | O2, or O2 N2O, or O2 N2O Air | O2, or O2 N2O | O 2 , or O 2 N 2 O |
Input pressure | 280~650 kpa | 280~650 kpa (350~400kpa is recommended) | 280~650 kpa (350~400kpa is recommended) |
Standard vent. mode | VCV, PCV,PLV | VCV, PCV,PLV | VCV, PLV |
Optional vent. mode | PCV, PSV, SIMV VCV PS, SIMV PCV PS | PCV (for 3000PS) | optional mechanical PEEP |
Electronic PEEP | YES | YES/NO | NO |
Display screen | Built-in 8.4" color | Built-in 5.7" monochrome | Built-in 3.0" LCD/LED |
Value display (Set and measured) | Tidal volume, minute volume, respiratory rate, I:E ratio, pressure limit Airway pressure (Ppeak, Pmean, Pmax, Pplateau, PEEP) FiO2%, Compliance (ml/cmH2O) Pressure support level, Inspiratory Window, P-trigger, Inspiratory End EtCO2 and InCO2 (optional) CSI, BS%, SQI%, EMG% | Tidal volume, minute volume, respiratory rate, I:E ratio, pressure limit Airway pressure (Ppeak, Pmean, Pmax, Pplateau, PEEP) FiO2%, Compliance (ml/cmH2O) | Tidal volume, minute volume, respiratory rate, I:E ratio, pressure limit Airway pressure (Ppeak, Pmean, Pmax, Pplateau, PEEP) FiO2% |
Graphic display | P-T, F-T, V-T waveforms P-V, P-F, F-V loops (for compliance, resistance, leakage analysis) EtCO2 waveforms (when optional EtCO2 module is present) CSI, BS%, SQI, EMG waveforms (when optional CSM is present) | P-T | P-T |
Optional expansion | Anesthetic gas scavenging system EtCO2 module (mainstream/sidestream) Anesthesia information management system External patient monitor Other equipment | Anesthetic gas scavenging system Anesthesia information management system External patient monitor Other equipment | Anesthetic gas scavenging system Anesthesia information management system External patient monitor Other equipment |
As a specializedanesthetic machine manufacturer and supplier in China, Heal Force also provideselectrosurgical generator, surgical operating table, fingertip pulse oximeter, and laboratorycentrifuge, among others.