Home Genius-15 Multi-Parameter Monitor

Genius-15 Multi-Parameter Monitor

Genius-15 Multi-Parameter Monitor

Genius-15 Multi-Parameter Monitor



Applications
Genius-15 multi-parameter monitor is especially designed for anaesthesiause. It can monitor standard parameters of ECG, SpO2, RESP, NIBP, TEMP and PR. With·a CSM module, it can alsomonitor parameters of CSI, EEG, EMG and BS% with alarm. 

Features
1.
Genius-15 multi-parameter monitorcomes with a 15" high resolution color LCD screen.
2. It uses a built-in printer which allows printing of values and curves ifneeded.
3. It has a portable handset with wireless connection to main unit for dataprocessing. 
4. The multi-parameter monitor adoptsdigital SpO2 technology that helps ensure anti-motion and anti-low perfusion.
5. It offersoptimized NIBP measurement modes for adult, neonatal andpediatric patients.
6. It allows automatic analysis of 20 arrhythmia waveforms.
7. The multi-parametermonitor can store up to 400 groups of data as well as 24 hourECG waveforms.
8. It provides protection against interference from defibrillator andelectrosurgical generator.
9. Automatic and manual analysis is available for S-T segment.

Genius-15 Multi-Parameter Monitor

Specifications of Genius-15Multi-Parameter Monitor


CSM

EEG sensitivity

±400μV

Noise level

<2μVp-p, <0.4μV RMS, 1~250Hz

CMR

>140dB

Input impedance

>50Mohm

Sample rate

2000 samples/sec. (14 bits equivalent)

CSI and update

0-100. Filter 6-42Hz, 1sec. update

EMG

0-100 logarithmic. Filter 75-85Hz, 1 sec. update

BS%

0-100%. Filter 2-42Hz, 1 sec. update

Wireless range

Up to 10 meters

ECG

Heart rate display range

15bpm ~ 350bpm

Heart rate display accuracy

± 1% or ± 2bpm, whichever is greater

Sweeping speed

12.5mm/s, 25mm/s, 50mm/s

Sensitivity selection

×1/2, 5mm/mV

×1, 10mm/mV

×2, 20mm/mV

CMRR

≥ 89dB

RESP

Measuring range

0rpm~120rpm

Accuracy

±5% or ±2 rpm

Alarm limits setting range

0rpm~120rpm

TEMP

Measuring range

25.0℃ ~45.0℃

Measuring accuracy

±0.2℃

Responding time

≤150s

NIBP

Measuring method

Oscillometric Technique

Measuring range

0mmHg~300mmHg

Accuracy

Maximal mean difference

±5 mmHg

Maximal standard deviation

8 mmHg

Measurement range

Adult

SYS 40 ~ 255 mmHg

MAP 20 ~ 215 mmHg

DIA 10 ~ 195 mmHg

Pediatric patient

SYS 40 ~ 200 mmHg

MAP 20 ~ 165 mmHg

DIA 10 ~ 150 mmHg

Neonate

SYS 40 ~ 135 mmHg

MAP 20 ~ 110 mmHg

DIA 10 ~ 95 mmHg

SpO2

Measuring range

35%~100%

Low perfusion capability

0.4%~5%

Accuracy

Not greater than 3% for SpO2 range from 70% to 100%

PR

Measuring range

30bpm~240bpm

Measuring accuracy

±2bpm or ±2%, whichever is greater

General

Power supply

100~240VAC, 50/60Hz

Rechargeable Li-ion battery

12V 2.3Ah

Display mode

15 inches TFT color LCD

Alarming mode

Audible and visible alarm


 


As a China-basedmulti-parameter monitor manufacturer, Heal Force supplies a broad range ofproducts, including surgical light, anesthetic machine, fingertip pulse oximeter, laboratory centrifuge,and others.


Recommended Products
Hot Products