Home UP-8000 Multi-Parameter Monitor

UP-8000 Multi-Parameter Monitor

UP-8000 Multi-Parameter Monitor

UP-8000 Multi-Parameter Monitor



Applications
Our UP-8000multi-parameter monitor is used for monitoring standard parameters of ECG,SpO2, RESP, NIBP, TEMP and PR. With a CSM module, it can also monitor parameters of CSI, EEG, EMGand BS% with alarms. The patient monitor is especially designed for anaesthesia use.

Features
1. The UP-8000 multi-parameter monitor uses a 12.1"high resolution color LCD screen.
2. It has a portablehandset with wireless connection to main unit for data processing.
3. The multi-parametermonitor offers optimized NIBP measurement modes for adult,neonatal and pediatric patients.
4. It achieves automatic analysis of 20 arrhythmia waveforms.
5. Both automatic and manual analysis is available for S-T segment.
6. The patient monitor adopts digital SpO2 technology that helps ensureanti-motion and anti-low perfusion.
7. It can store up to 400 groups of data as well as 24 hour ECG waveforms.
8. The multi-parametermonitor offers protection against interference fromdefibrillator and electrosurgical generator.
9. It has a built-in thermal printer.

Specifications of UP-8000 Multi-Parameter Monitor

UP-8000 Multi-Parameter Monitor

CSM

EEG sensitivity

±400μV

Noise level

<2μVp-p, <0.4μV RMS, 1~250Hz

CMR

>140dB

Input impedance

>50Mohm

Sample rate

2000 samples/sec. (14 bits equivalent)

CSI and update

0-100. Filter 6-42Hz, 1sec. update

EMG

0-100 logarithmic. Filter 75-85Hz, 1 sec. update

BS%

0-100%. Filter 2-42Hz, 1 sec. update

Wireless range

Up to 10 meters

ECG

Heart rate display range

15bpm ~ 350bpm

Heart rate display accuracy

± 1% or ± 2bpm, whichever is greater

Sweeping speed

12.5mm/s, 25mm/s, 50mm/s

Sensitivity selection

×1/2, 5mm/mV

×1, 10mm/mV

×2, 20mm/mV

CMRR

≥ 89dB

RESP

Measuring range

0rpm~120rpm

Accuracy

±5% or ±2 rpm

Alarm limits setting range

0rpm~120rpm

TEMP

Measuring range

25.0 ℃ ~45.0℃

Measuring accuracy

±0.2 ℃

Responding time

≤150s

NIBP

Measuring method

Oscillometric Technique

Measuring range

0mmHg~300mmHg

Accuracy

Maximal mean difference

±5 mmHg

Maximal standard deviation

8 mmHg

Measurement range

Adult

SYS 40 ~ 255 mmHg

MAP 20 ~ 215 mmHg

DIA 10 ~ 195 mmHg

Pediatric patient

SYS 40 ~ 200 mmHg

MAP 20 ~ 165 mmHg

DIA 10 ~ 150 mmHg

Neonate

SYS 40 ~ 135 mmHg

MAP 20 ~ 110 mmHg

DIA 10 ~ 95 mmHg

SpO2

Measuring range

35%~100%

Low perfusion capability

0.4%~5%

Accuracy

Not greater than 3% for SpO2 range from 70% to 100%

PR

Measuring range

30bpm~240bpm

Measuring accuracy

±2bpm or ±2%, whichever is greater

General

Power supply

100~240VAC, 50/60Hz

Rechargeable Li-ion battery

12V 2.3Ah

Display mode

12 inches TFT color LCD

Alarming mode

Audible and visible alarm


 


Heal Force is anexperienced multi-parameter monitor manufacturer and supplier in China. Weprovide various types of products such as electrosurgical generator, OR ceilingsupply unit, CO2 incubator, and fetal Doppler monitor.