Off-Grid Power Inverter without Charger
Model: SMX Series
The off-grid power inverter without charger is used in off grid solar powersystems. It converts DC current generated from the solar panels into AC currentto loads. If in the absence of sunshine, this power inverter can also functionas a back-up power supply. Details please see the diagram below.
Featuresof the Off-Grid Power Inverter without Charger
1. The off-grid power inverterwithout charger offers multi-protection for maximum safety.
2. Based on DSP efficient processing power, it realizes many transformer-less invertersin parallel and simplifies the power station design.
3. The supporting software makes remote monitoring andcontrolling by computer easy.
Technical Specifications of the Off-GridPower Inverter without Charger
Model | SMX-1K/1S | SMX-1K5/1S | SMX-2K/1S | SMX-2K5/1S | SMX-3K/1S | SMX-4K/1S | SMX-4K8/1S | |
INPUT(DC) | Recommended Input Power. W | 1200 | 1750 | 2100 | 2625 | 3150 | 4200 | 5250 |
Max. PV Input DC Current. A | 6 | 11 | 13 | 16 | 19 | 27 | 32 | |
MPPT Voltage Range DC. V | 180~ 360 | |||||||
Number of MPPT Trackers/Max. Number of Strings (parallel) | 1/1 | 1/1 | 1/1 | 1/1 | 1/1 | 1/1 | 1/1 | |
Continues AC Output Power. W | 1000 | 1500 | 2000 | 2500 | 3000 | 4000 | 4800 | |
Max. AC Output Current. A | 5.45 | 8.18 | 10.91 | 13.64 | 16.36 | 21.82 | 26.18 | |
Grid Voltage. A | 220/220±20% or adjusted to local regulation | |||||||
Grid Frequency/Range | 50/60±0.5Hz or adjusted to local regulation | |||||||
Factor | ≥0.99999999 | |||||||
THD (%) | Less than 3% | |||||||
Max. Efficiency | 97% | |||||||
European-Efficiency | 95.50% | |||||||
Protection |
| Over voltage protection, Under voltage protection, Over frequency protection. Under frequency protection, Over current protection, AC short-circuits protection, Ground fault protection, DC Reverse polarity protection, Over load protection | ||||||
General Data | Dimensions(H/W/D)mm | 454/270/182 | 454/270/182 | 466/270/181 | 466/270/181 | 466/270/181 | 538/310/181 | 538/310/181 |
Weight (kg) | 18 | 19 | 20 | 20 | 20 | 25 | 25 | |
Operating Temperature. ℃ | -25~ 50 ℃ | |||||||
Standby Power Consumption | 10W | |||||||
Noise | ≤ 42 dB(A) | |||||||
Topology | Transformer-less | |||||||
Cooling Concept | Natural cooling | |||||||
Protection Grade | IP65 | |||||||
Features | Graphic Display | LCD | ||||||
Interfaces | RS485/RS232 | |||||||
Software | SFENGINEER |
Model | SMX-6K/1S | SMX-7K/1S | SMX-8K/1S | SMX-9K/1S | SMX-10K/1S | |
INPUT(DC) | Recommended Input Power. W | 7000 | 8500 | 9500 | 11000 | 12750 |
Max. PV Input DC Current. A | 40 | 46 | 53 | 60 | 65 | |
MPPT Voltage Range DC. V | 300~600 | |||||
Number of MPPT Trackers/Max. Number of Strings (parallel) | 1/3 | 1/3 | 1/3 | 1/3 | 1/3 | |
Continues AC Output Power. W | 6000 | 7000 | 8000 | 9000 | 10000 | |
Max. AC Output Current. A | 32 | 38 | 43 | 49 | 54 | |
Grid Voltage. A | 220/220±20% or adjusted to local regulation | |||||
Grid Frequency/Range | 50/60±0.5Hz or adjusted to local regulation | |||||
Factor | ≥0.99999999 | |||||
THD (%) | Less than 3% | |||||
Max. Efficiency | 0.97 | |||||
European-Efficiency | 0.955 | |||||
Protection |
| Over voltage protection, Under voltage protection, Over frequency protection, Under frequency protection, Over current protection, AC short-circuits protection, Ground fault protection, DC Reverse polarity protection, Over load protection | ||||
| Operating Temperature. ℃ | -25~ 50 ℃ | ||||
Standby Power Consumption | 5W | |||||
Noise | ≤ 42 dB(A) | |||||
Topology | Transformer-less | |||||
Cooling Concept | Natural cooling | |||||
Protection Grade | IP65 | |||||
Features | Graphic Display | LCD | ||||
Interfaces | RS485/RS232 | |||||
Software | SFENGINEER |
As a China-based manufacturer of off-grid power inverter without charger, wealso offer pure sine wave inverter with charger, grid tie power inverter, monocrystalline solar panel, andmuch more.