Home Off-Grid Power Inverter with Charger

Off-Grid Power Inverter with Charger

Off-Grid Power Inverter with Charger

Off-Grid Power Inverter with Charger

Model: SMBSeries

The off-grid powerinverter with charger is used in off grid solar power systems. It converts DCcurrent generated from the solar panels into AC current to loads, and if inabsence of sunshine, the utility could be a back up power supply. If the powergenerated is enough for loads, the inverter will charge excess electricity tothe battery. While no PV input and utility, it will use power from the batteryautomatically. See the diagram below.

Featuresof Off-Grid Power Inverter with Charger
1. The off-grid inverter with charger has alarge screen LCD display withmultilingual for options.
2. It offers up to five years metering of power generation and CO2 emissions.
3. Supporting software makes remote monitoring and controlling by computereasy.

Technical Specifications of the Off-GridPower Inverter with Charger

Off-Grid Power Inverter with Charger

Model

SMB-1K/1S

SMB-1K5/1S

SMB-2K/1S

SMB-2K5/1S

SMB-3K/1S

SMB-4K/1S

SMB-4K8/1S

INPUT(DC)

Recommended Input Power. W

1200

1750

2100

2625

3150

4200

5250

Max. PV Input DC Current. A

6

11

13

16

19

27

32

MPPT Voltage Range DC. V

180~ 360

Number of MPPT Trackers/Max. Number of Strings (parallel)

1/1

1/1

1/1

1/1

1/1

1/1

1/1

Recommend Batteries Num.12V

16

16

14

14

14

16

16

Continues AC Output Power. W

1000

1500

2000

2500

3000

4000

4800

Max. AC Output Current. A

5.45

8.18

10.91

13.64

16.36

21.82

26.18

Grid Voltage. A

220/220±20% or adjusted to local regulation

Grid Frequency/Range

50/60±0.5Hz or adjusted to local regulation

Factor

≥0.99999999

THD (%)

Less than 3%

Max. Efficiency

97%

European-Efficiency

95.50%

Protection

 

Over voltage protection, Under voltage protection, Over frequency protection. Under frequency protection, Over current protection, AC short-circuits protection, Ground fault protection, DC Reverse polarity protection, Over load protection

General Data

Dimensions(H/W/D)mm

454/270/182

454/270/182

466/270/181

466/270/181

466/270/181

538/310/181

538/310/181

Weight (kg)

18

19

20

20

20

25

25

Operating Temperature. ℃

-25~ 50 ℃

Standby Power Consumption

10W

Noise

≤ 42 dB(A)

Topology

Transformer-less

Cooling Concept

Natural cooling

Protection Grade

IP65

Features

Graphic Display

LCD

Interfaces

RS485/RS232

Software

SFENGINEER



Model

SMB-6K/1S

SMB-7K/1S

SMB-8K/1S

SMB-9K/1S

SMB-10K/1S

INPUT(DC)

Recommended Input Power. W

7000

8500

9500

11000

12750

Max. PV Input DC Current. A

40

46

53

60

65

MPPT Voltage Range DC. V

300~600

Max. BAT Input DC Current

35

37

42

47

52

Recommend Batteries Num.12V

above 14

above 14

above 14

above 14

above 14

Number of MPPT Trackers/Max. Number of Strings (parallel)

1/3

1/3

1/3

1/3

1/3

Continues AC Output Power. W

6000

7000

8000

9000

10000

Max. AC Output Current. A

32

38

43

49

54

Grid Voltage. A

220/220±20% or adjusted to local regulation

Grid Frequency/Range

50/60±0.5Hz or adjusted to local regulation

Factor

≥0.99999999

THD (%)

Less than 3%

Max. Efficiency

0.97

European-Efficiency

0.955

Protection

 

Over voltage protection, Under voltage protection, Over frequency protection, Under frequency protection, Over current protection, AC short-circuits protection, Ground fault protection, DC Reverse polarity protection, Over load protection

 

Operating Temperature. ℃

-25~ 50 ℃

Standby Power Consumption

5W

Noise

≤ 42 dB(A)

Topology

Transformer-less

Cooling Concept

Natural cooling

Protection Grade

IP65

Features

Graphic Display

LCD

Interfaces

RS485/RS232

Software

SFENGINEER