Applications of HP9116C & HP9316C series 6-20kVA UPS
HP9116C & HP9316C series 6-20kVA is quite suitable for servers, data centers, critical network devices, sensitive electronic equipment, telecommunications, etc.
Features of HP9116C & HP9316C series 6-20kVA UPS
1. Designed with true on-line double conversion technology, and employs advanced microprocessor control.
2. Wide input voltage.
3. Zero transfer time.
4. Protection against all types of power problems.
5. No add-on CNTL unit required for parallel connection.
6. Site wiring fault warning.
7. Low initial investment and flexible for future expansion.
8. Good reliability and performance for power sharing and redundancy.
9. Equipped with maintenance bypass switch.
10. Smart RS232 communication interface.
11. Intelligent slot is available.
12. Sealed, lead-acid, and maintenance free battery.
Features
1. Adopts LCD to display the detailed real-time UPS status.
2. Microprocessor control guarantees high reliability.
3. Equipped with boost and buck AVR to stabilize input voltage.
4. Built-in DC start function is designed to start UPS while AC power supply is unavailable.
5. HP9116C & HP9316C series UPS products are installed with smart RS-232 communication port. You can download software from the internet.
6. User-replaceable battery design.
7. Auto charge even though UPS is off.
8. Auto restart while AC recovery.
9. Provides modem or phone line surge protection.
10. Provides discharge, overcharge, and overload protection.
11. USB port is available upon request.
Technical Specifications
Product series | HP9116C 6 - 10kVA (1 PH / 1 PH) | HP9316C 10 - 20kVA (3PH / 1PH) | ||||||
Model number | 6KT | 10KT | 6KT-XL | 10KT-XL | 10KT-XL | 15KT-XL | 20KT-XL | |
Rated power | Volt-amps/Watts | 6kVA/4.2KW | 10kVA/8KW | 6kVA/4.2KW | 10kVA/7KW | 10Kva/7KW | 15Kva/10.5KW | 20Kva/14KW |
Input | Low line transfer | 176VAC ± 3VAC | 304VAC ± 3VAC | |||||
Low line comeback | 185VAC ± 3VAC | 322VAC ± 3VAC | ||||||
High line transfer | 276VAC ± 3VAC | 478VAC ± 3VAC | ||||||
High line comeback | 266VAC ± 3VAC | 461VAC ± 3VAC | ||||||
Frequency range | 50Hz, 46-54Hz, 60Hz, 56-64Hz. | |||||||
Power factor | ≥ 0.98 | ≥ 0.95 | ||||||
Phase | Single Phase with ground | Three phase (4 Wires ground) | ||||||
Connection | Hardwired | |||||||
Output | Voltage | 220VAC or 230VAC or 240VAC | ||||||
Voltage regulation | ± 1% | |||||||
Frequency | Synchronization range (line mode); 50 or 60Hz × (1 ± 0.05% ) Hz (battery mode) | |||||||
Power factor | 0.7 or 0.8 | |||||||
Wave form | Pure sine wave | |||||||
Phase | Single phase | |||||||
Voltage distortion | ≤ 2% THD (linear load), ≤ 6% THD (non - linear load) | |||||||
Overload capability | 105%~130% for 10 min., more than 130% for 1 second | |||||||
Current crest ratio | 3:1 max | |||||||
Connection | Hardwired | |||||||
Battery | Type | Valve regulated, sealed, lead-acid | External battery bank | |||||
Nominal DC voltage | 240VDC | |||||||
Backup time (full load) | 7 min | 5 min | Depends on the external battery capacity | |||||
Recharge time | 7 hours to 90% | 8 hours to 90% | Depends on the external battery capacity | |||||
Charge current (max.) | 2A | 4.2A | ||||||
Charge voltage | 274Vdc ± 1V | |||||||
Transfer time | AC to DC | 0 ms | ||||||
Inverter to bypass | 2.5 ms (typical) | |||||||
Indicators | Status | Load level / battery level, battery, utility power, inverter, bypass, overload, fault. | ||||||
Audible alarm | Bypass | Alarm beeps every two seconds | ||||||
Battery discharge | Alarm beeps every four seconds. Alarm beeps every one second if battery capacity is low. | |||||||
Overload | Alarm beeps twice every one second | |||||||
Fault | Alarm beeps continuously | |||||||
Maintenance bypass switch | Yes | |||||||
Communications interface | DB-9 Port | RS-232 serial interface | ||||||
Intelligent slot | Options: SNMP card, AS400 card or Win power CMC / (USB port) | |||||||
Parallel port | Availability of up to three units in parallel for power redundancy and load sharing | |||||||
Environment | Operating temperature | 0 ~ 40℃ | ||||||
Operating humidity | 20 ~ 90% non-condensing | |||||||
Noise level | Less than 55dB@1 meter | Less than 60dB@1 meter | ||||||
Physical feature | Weight net (Kg) | 90 | 93 | 35 | 38 | 39 | 55 | |
Body size W×D×H (mm) | 260×570×717 |