Home HP9330C series 20-80kVA UPS

HP9330C series 20-80kVA UPS

HP9330C series 20-80kVA UPS


Application of HP9330C series 20-80kVA UPS
HP9330C series 20-80kVA UPS is particularly applicable to severs, data centers, critical network devices, sensitive electronic equipment, telecommunications, etc.


Features


1. N X parallel redundancy
The maximum of the inbuilt parallel mode is 8 pieces of UPS. In addition, battery is compatible in the parallel mode.


2. High-efficient DSP chip
Installed with digital DSP controlling chip, HP9330C series UPS products have precise data processing capacity. Furthermore, it is stable in output, and reliable in performance.




3. Outstanding electric property
The efficiency of the machine is 93%, and even reaches over 98% in the EC mode. The input power factor is as high as 0.99.


4. Twin-channel line input
HP9330C series UPS products can offer you safe power supply. You can choose either two-line input or one-line input according to the actual condition. Besides, smart battery is available.


Technical Parameters of HP9330C series 20-80kVA UPS


Product seriesHigh Frequency Online UPS 20-80kVA (3PH/3PH)
Model20K20K-XL30K30K-XL40K40K-XL60K-XLISO80K-XLISO
CapacityVA/W20KVA/16KW20KVA/16KW30KVA/24KW30KVA/24KW40KVA/32KW40KVA/32KW60KVA/48KW80KVA/64KW
Rectifier inputRectifier typeIGBT-based vector controlled PFC (PF corrected)
Input voltage380/400/415VAC(Accepted from 305 to 477 with ptebatt.use)
Input frequency50 or 60 Hz (accepted from 40 to 70)
Input current THD3% (without any filter)
Input power factor≥0.99 (with any filter)
Power walk-in5 to 30s (selectable)
Bypass inputInput voltage380/400/415VAC
BatteryBattery typeVRLA (valve regulated lead acid) or wet / flooded or NiCd
End-cell voltageSelectable from 1.60 to 1.90Vdc / Cell (for VRLA)
DC ripple current(float)<5% (of C 10 AH capacity) RMS value
DC ripple voltage(float and const V Ch)<1% (RMS value)
Temp.conp. ChargeStandard (where internal batteries is 10,15,20,30,40 kVA) and optional (for all other battery configurations)
Output Inverter typeIGBT-based vector, repetitive and PI controlled
Output voltage380/400/415VAC ± 0.5 regulation (3-phase RMS average)
Output frequency50 or 60Hz with ± 0.05 regulation
Output voltage THD1% (max)
Max. load crest factor3:1 (compliant with IEC 62040-3)
Transient Volt. Resp10ms to recover ± 5% of nominal voltage for 0% to 100% or 100% to 0% step load
Max. leading PF loadUp to 0.9
Voltage displacement120° ± 10° (with100% unbalanced load)
Overload110% for 60 minutes,125% for 10 minutes,150% for 1 minute
EfficiencyAC-ACUp to 0.9
EMC-classClass - A (applicable for both radiated and conducted)
EnvironmentalStorage temperature-20 to 70℃ (UPS) and 25 ± 5 (battery)
Operating temperature0 to 40℃ (UPS)and 25 ± 5 (battery)
Relative humidity0 to 95% (non-condensing)
Maximum altitude abovemean sea level1000m (as per IEC 62040/3)
Main unitDimension (W×D×H) mm420X600X1250420X600X950470X700X1750470X700X1150470X700X1750470X700X11503600X800X18503600X800X1850
Weight(kg)15882220110224114282306
UPS enclosure IPIP 20 (even with open front door)

Standard
IEC 62040-3             EN 50091-1-1       ANSI C62.41 (IEEE 587)
IEC 62040-2             EN 50091-2
IEC 62040-1-1         EN 50091-3
IEC 60146-1-1         EN 60950
IEC 61000-4-2, 4, 5,6, 8,11                   EN 60529