Application of HP9116CR & HP9316CR series Rack Mount Online UPS
HP9116CR & HP9316CR series rack mount online UPS is widely suitable for servers, data-center, critical network devices, sensitive electronics, telecommunications, etc.
Features
1. Designed with true online double conversion technology, and employs advanced microprocessor control.
2. Wide input voltage range.
3. Zero transfer time
4. Protection against all types of power problems.
5. Self test while starting UPS.
6. Site wiring fault warning.
7. On-battery power-on function.
8. Smart RS232 communication interface.
9. Intelligent slot is available.
10. Sealed, lead-acid, and maintenance-free battery.
Technical Parameters of HP9116CR & HP9316CR series Rack Mount Online UPS
Product series | Rack Mount UPS 1-10kVA | |||||
Model | 1KR/1KR-XL | 2KR/2KR-XL | 3KR/3KR-XL | 6KR/6KR-XL | 10KR/10KR-XL | |
Input | VA/W | 1kVA/0.7W | 2kVA/1.4KW | 3kVA/2.1KW | 6kVA/4.2W | 10kVA/7KW |
Nominal voltage | 110/115/120VAC or 220/230/240VAC | 220/230/240VAC | ||||
Voltage range | 60-138VAC or 180-300VAC | 176-276VAC | ||||
Frequency range | 50HZ, 46-54Hz or 60Hz, 56-64Hz | |||||
Power factor | >0.97 | >0.98 | ||||
Connection | IEC320-10A inlet | IEC320-10A inlet | IEC320-16A inlet | Terminal block | ||
Output | Voltage | 110/115/120×(1±1%)VAC or 220/230/240×(1±1%)VAC | 220/230/240×(1±1%)VAC | |||
Frequency | Synchronization range (line mode), 50 or 60×( 1±0.2%)Hz (Battery mode) | |||||
Waveform | Sine wave | |||||
Overload capability | 110%-150% for 30 sec, ≥150% for 300 ms | 105%-130% for 10 min, ≥130% for 1 ms | ||||
Current crest radio | 3:1 | |||||
Bypass | Automatic transfer | On overload and UPS failure | ||||
Before UPS power-on | Default "ON" user adjustable to "YES" | YES | ||||
Voltage range | 40-132VAC (default), Voltage is adjustable within 40-143VAC ; 80-264VAC (default), Voltage is adjustable within 80-286VAC. | 176-261VAC | ||||
Transfer time | 0 ms, less than 4 ms from inverter to bypass and vice versa | Zero | ||||
Output connections | IEC320-10A *4 | IEC320-10A *4 | IEC320-10A *4 and terminal block | IEC320-10A *4 and terminal block | IEC320-10A *4 and terminal block | |
Indicator | UGR/LED display | Load level / battery level, battery, utility power, inverter, bypass, overload, fault. | ||||
UXR/LCD display | UPS status, I/P and O/P voltage and frequency, battery voltage, loading, temperature, history record. | |||||
Audible alarm | Bypass, on battery mode, battery low, overload, fault. | |||||
Communications | DB-9 Port | RS-232 serial interface | ||||
Intelligent slot | Option: SNMP card, AS400 card or Win power CMC. | |||||
Network surge protection | RJ45 I/O port is available for network or fax/modem | |||||
Environment | Operating temperature | 0-40℃ | ||||
Operating humidity | 20-90% non-condensing | |||||
Main unit | Net weight(kg) | 16.3/9.1 | 10.3/11.5 | 11.2/12.3 | 18.3/19.5 | 20.3/21.5 |
Battery pack | Dimensions (W×D×H) mm | 482.6×450×89(2U) | 482.6×600×133.5(3U) | 482.6×600×133.5(4U) | ||
Type | Internal batteries | External battery pack | ||||
Nominal voltage | 36VDC | 96VDC | 96VDC | 240VDC | 240VDC | |
Backup time (full load) | 5 min | 9 min(with 1 BP) | 5 min(with 1 BP) | 7 min(with 1 BP) | 7 min(with 1 BP) | |
Net Weight(kg) | 25.3 | 25.3 | 58.2 | 58.2 | ||
Dimensions | 482.6×450×89(2U) | 482.6×600×133.5(3U) |