Application of G-GM Series 1-3kVA UPS
G-GM series 1-3kVA can be applicable to servers, data centers, critical network devices, sensitive electronic equipment, telecommunications, etc.
Features of G-GM Series 1-3kVA UPS
1. Designed with online double conversion technology, and employs advanced microprocessor control.
2. Wide input voltage range.
3. Zero transfer time.
4. Protection against all types of power problems.
5. Self test while starting the UPS.
6. Site wiring fault warning.
7. On-battery power-on function.
8. Smart RS232 communication interface.
9. Intelligent slot is available.
10. Sealed, lead-acid, and maintenance free battery.
Technical Specifications
Model | G1K | G2K | G3K | G1KS | G2KS | G3KS | |
GM1K | GM2K | GM3K | GM1KS | GM2KS | GM3KS | ||
Capacity | VA/W | 1kVA/0.7KW | 2kVA/1.4KW | 3kVA/2.1KW | 1kVA/0.7KW | 2kVA/1.4KW | 3kVA/2.1KW |
Input | Nominal voltage | 110/115/120 VAC or 220/230/240 VAC | |||||
Voltage range | 180-300VAC | ||||||
Frequency range | 50Hz, 46-54Hz, 60Hz, 56-64Hz. | ||||||
Phase | Single phase | ||||||
Power factor | >0.97 | ||||||
Connection | IEC320-10A inlet | IEC320-10A inlet | IEC320-16A inlet | IEC320-10A inlet | IEC320-10A inlet | IEC320-16A inlet | |
Output | Voltage | 110/115/120× (1±2%) VAC, 220/230/240×(1±2%)VAC | |||||
Frequency | Synchronization range (line mode), 50 or 60Hz×(1±0.2%) (Battery mode) | ||||||
Phase | Single phase | ||||||
Wave form | Sine wave | ||||||
Power factor | 0.7 or 0.8 optional | ||||||
Voltage distortion | 3% | 4% | 4% | 3% | 4% | 4% | |
Overload capability | 110%-150% for 30 sec., ≥150% for 200 ms | ||||||
Current crest radio | 3: 1 | ||||||
Connections | IEC320*4 | IEC320*6 | IEC320*3 terminal block | IEC320*4 | IEC320*6 | IEC320*3terminal block | |
Battery and charge | Type | Sealed, maintenance free, and lead-acid | |||||
Nominal DC to voltage | 36VDC | 96VDC | 96VDC | ||||
Quantity | 3 pieces | 8 pieces | 8 pieces | Depends on the requested back-up time | |||
Back-up time(full load) | 5 min | 9 min | 5min | Depends on the capacity of the external battery bank | |||
Recharge time | 5 hrs to 90% of capacity | Depends on the capacity of the external battery bank | |||||
Automatic transfer | On overload and UPS failure | ||||||
Before UPS power-on | Default 'ON' user adjustable to 'YES' | ||||||
Voltage range | 40-132VAC (default), user can adjust the voltage within 40-143VAC; 80-264VAC (default), user can adjust the voltage within 80-286VAC. | ||||||
Transfer time | AC to DC zero | Inverter to bypass 4 ms (typical) | |||||
Indicators | UG/LED display | Load level / battery / lever, battery, utility power, inverter, bypass, overload, fault | |||||
UX/LCD display | UPS status, I/P and O/P voltage and frequency, battery voltage, battery capacity, loading, temperature, history record | ||||||
Audible alarm | Bypass, on battery mode, battery low, overload, fault | ||||||
Acoustic noise | At 1 meter distance | <45 dB | <50 dB | <50 dB | <45 dB | <50 dB | <50 dB |
Communications | DB-9 port | PS-232 serial interface | |||||
Intelligent slot | Options: SNMP card, AS400 card or Win power CMC / (USB port) | ||||||
Environment | Operating temperature | 0-40℃ | |||||
Operating humidity | 20-90% non-condensing | ||||||
Weight | Net(Kg) | 13 | 31.5 | 32 | 7 | 13.5 | 14 |
Dimensions (package) | W ×D ×H (mm) | 240×495×335 | 335×590×480 | 355×590×480 | 240×495×335 | 335×590×480 | 335×590×480 |
As a primary UPS product manufacturer in China, SH Power Co.,Ltd. is dedicated to produce high quality off line UPS, high frequency online UPS, low frequency online UPS, and more. Those products employ advanced digital control technology, and have strong extended function. Currently, our products are CE certified and exported to the United States, Russia, Austria, Brazil, and other countries as a result of high quality and economical prices.