Home HP9117C Series 1-3kVA UPS

HP9117C Series 1-3kVA UPS

HP9117C Series 1-3kVA UPS


The Application of HP9117C Series 1-3kVA UPS
HP9117C series 1-3kVA can be widely used for servers, data centers, critical network devices, sensitive electronic equipment, telecommunication, etc.


Features of HP9117C Series 1-3kVA UPS
1. Designed with DSP control technology.
2. HP9117C series 1-3kVA UPS adopts fully digital control technology, so it can provide higher precision and better drift-proof control, compared with traditional analog electronics.
3. Various languages such as English, Russian, German, French and Spanish can be displayed by LED.
4. The input power factor is more than 0.98 and output power factor is 0.9.
5. The output frequency is 50HZ or 60HZ. Additionally, a frequency converter can be installed to adjust the frequency.
6. Smart battery is available.
7. Smart RS-232, intelligent slot, USB and EPO communication port are installed in HP9117C series 1-3kVA.

HP9117C Series 1-3kVA UPS


The Parameters of HP9117C Series 1-3kVA UPS


Model1KT/1KR1KT-XL/1KR-XL2KT/2KR2KT-XL/2KR-XL3KT/3KR3KT-XL/3KR-XL
CapacityVA/W1000VA/900W2000VA/1800W3000VA/2700W
InputNominal voltage100/110/120/127 VAC or 200/208/220/230/240 VAC
Operating voltage range60-138VAC or 120-276VAC
Frequency rangeThe input frequency is in the range of 40 to 70 Hz. HP9117C series 1-3kVA can automatically select nominal frequency (50Hz or 60Hz) for inverter to match input (Auto sync.)
PhaseSingle phase
Power factor> 0.98
Cold start (0 to 100% load)Yes
OutputVoltage100, 110, 120, 127 VAC (±2%) or 200, 208, 220, 230, 240 VA (±2%)
Frequency50 Hz or 60 Hz (automatic selection) or configurable frequency according to the frequency converter
Wave formSine wave
Power factor0.9
Voltage distortionR load < 3 % THD, RCD load < 5 % THD
Overload capacityTransfer to bypass if available, or shut down. Reference data: 100% < load < 102%, overload warning; 102% < load < 130%, 12s; 130% < load < 150%, 2s.
Current crest ratio3:1
ConnectionHardwired
Efficiency>82% (1 kVA) >84% (2-3kVA)
BatteryTypeValve regulated lead acid battery (VRLA), minimum 3 years float service life at 25℃.
Nominal DC voltage36VDC36VDC96VDC96VDC96VDC96VDC
Quantity3x12V/7Ah3*12V/7Ah8*12V/7Ah
Transfer time0 ms (no break) in online mode, 5 ms (max) in high efficiency mode due to loss of utility.
BypassAutomatic bypass to provide an alternate path to utility power in case of overload, or internal failure.
Bypass is permitted only when frequency is within ±5 HZ of nominal frequency, and voltage is within 10 / -15 V (CS) of nominal voltage. Beyond this range, bypass is not available and will not occur (CS).
User interfaceLCD displayUPS status, I/P and O/P voltage and frequency, battery voltage, battery capacity, loading, temperature, and history record.
LanguageEnglish, German, French, Spanish, Russian (other language packs can be loaded)
CommunicationsDB-9 portRS-232, XCP, Relay mode
Intelligent slotOptions: SMNP Card, AS400 Card or Win power CMC / USB port
EnvironmentOperating temperature(At sea level) 0-40℃ online Mode. The unit will be derated linearly for altitude, Max altitude refer to 10.5.
Note: thermal protection device can transfer load to bypass in case of overheating.
Operating humidity5-90% non-condensing
Acoustic noise<45dB <45dB <50dB (2000~3000VA)
Physical featureWeight15, 7.5, 33.5, 14, 34, 14.5.
Dimensions (H x W x D)(mm)230.6*160*350 230.6*160*350 325*214*380 325*214*380 325*214*380 325*214*380

SH Power Co.,Ltd. is an ISO9001: 2000 certified UPS equipment manufacturer based in China. We mainly specialize in produce various off line UPS, on-line UPS, line-interactive UPS, high frequency online UPS, low frequency online UPS, and more.


Those products have high working efficiency and have been inspected strictly before put into the market. Hence, you can trust the quality.


For further inquiries and purchase, please contact us at SH Power Co.,Ltd. by phone or email addresses provided on this website.


Thank you very much for visiting our website.










Recommended Products
Hot Products