TXF Series UPS
TXF series onlineuninterruptible power supply is suitable for critical servers, storageapplication and other networking equipment.
Features
1)True On-line doubleconversion design providing all power protection
2)Sine wave pulse width modulation
3)IGBT I inverter design
4)Wide input voltage range
5)Pure sine wave output with less than 3% THD
6)Expandable backup time
7)Generator compatible
8)Load/battery power LCD display
9)Overload, on-line, battery status LED LCD
10)Advanced Battery Management
11)Automatically charging in ups OFF mode
12)Zero transfer time on AC mode to/from battery, AC mode to/from bypass
13)Smart RS232 communication port
14) Optional SNMP cards
Technical Parameters
Series | TXF Series |
| ||||||||||
Model | 1KVA | 2KVA | 3KVA | 4KVA | 6KVA | 8KVA | 10KVA | 12KVA | 15KVA | 20KVA |
| |
Capacity(w) | 0.8KW | 1.6KW | 2.4KW | 3.2KW | 4.8KW | 6.4KW | 8KW | 9.6KW | 12KW | 16KW |
| |
Input | Voltage Range | 180~260VAC or 90~130VAC |
| |||||||||
Frequency | 50/60HZ±5% |
| ||||||||||
Phase | Single phase GND |
| ||||||||||
Max input current(110V) | 12A | 20A | 48A | 28A | 68A | 90A | 110A | 136A | 168A | 220A |
| |
Max input current(220V) | 6A | 10A | 14A | 24A | 34A | 45A | 56A | 68A | 84A | 112A |
| |
Output | Voltage Range | 220VAC±1%or110VAC±1% |
| |||||||||
Frequency | 50/60HZ±0.5% |
| ||||||||||
Phase | Single phase GND |
| ||||||||||
THD | <3%(linear load) |
| ||||||||||
Power Factor | 0.8 |
| ||||||||||
Short Circuit Protection | Current limit, turn off automatically, switch protect |
| ||||||||||
Overload Capacity | Overload(110%-150%),20s later go to bypass, automatically resume when load become normal | |||||||||||
Battery | Type | Sealed lead acid, maintenance free |
| |||||||||
DC | 48VDC(192V Optional) | 192VDC |
| |||||||||
Charge current | 4.2A | 4.2A | 4.2A | 4.2A | 4.2A | 4.2A | 4.2A | 4.2A | 4.2A | 4.2A |
| |
Charge Time | 90% capacity after 8 hours |
| ||||||||||
Panel indication | LCD | Working mode, I/P and O/P voltage, I/P and O/P frequency, Battery voltage, load percentage, UPS inner temperature | ||||||||||
LED | low battery, online, inverter, bypass, abnormal |
| ||||||||||
Efficiency | Whole unit | 0.8 |
| |||||||||
Communication | 1.Power status 2.UPS shutdown 3.monitor UPS status 4.UPS self test 5.auto-save files | |||||||||||
Protection | Surge Protection | IEEE527B |
| |||||||||
Noise | FCC.A |
| ||||||||||
Audible Noise | <55DB (at 1 meter) |
| ||||||||||
Environment | Temperature | 0~40℃ |
| |||||||||
Humidity | 0%~95% |
| ||||||||||
General | Net weight(without battery) | 46kg | 63kg | 75kg | 65kg | 69kg | 105kg | 115kg | 120kg | 210kg | 250kg |
|
Packing(W×D×H)mm | 320×620×730 | 350×725×810 | 470×765×916 | 726×485×1176 |
|
TianXin Electrical Co., Ltd. is a leading internationalmanufacturer of high quality power supply testing equipment, located in China. At TianXin, we can supply you high quality power supplytesting equipment such as AC automatic voltage regulator, uninterruptible powersupply, solar inverter, DC power supply and batterycharger.