TXE Series UPS
TXE series uninterruptiblepower supply (UPS) can be used for big computer data center, industrial processand other miss-critical equipment.
Features
1)Three phase in, threephase out
2)True On-line double conversion design providing all power protection
3)Sine wave pulse width modulation
4)Double DSP digital control
5)LCD with control panel
6)Remote management
7)Advanced Battery Management
8)Parallel redundant
9)Self diagnose
10)Low noise
11)Wide input voltage range
12)High efficiency cuts down your expense
Technical Parameters
Model | TXE series | ||||||||
Capacity | 10KVA | 15KVA | 20KVA | 30KVA | 40KVA | 60KVA | 80KVA | 100KVA | 120KVA |
Power(W) | 8KW | 12KW | 16KW | 24KW | 32KW | 48KW | 64KW | 80KW | 96KW |
Power Factor | 0.8 | ||||||||
Input |
| ||||||||
Phase | 3 phase 4 wire and ground | ||||||||
Voltage Range | ±20% | ||||||||
Frequency Range | 45~65HZ | ||||||||
Rectifier | 3 phase 6 pulses | ||||||||
Output |
| ||||||||
Phase | 3 phase 4wire and ground | ||||||||
Wave form | Sine wave | ||||||||
Crest Factor | 3:1 | ||||||||
Rated voltage | 380/400/415V optional | ||||||||
Phase voltage setting | 200-244VAC(control panel) | ||||||||
Transient response | ±5%,10ms | ||||||||
Frequency | 50/60HZ | ||||||||
Frequency stability | ±0.05% | ||||||||
Range of phase lock | With synchronization;±0.05% Without synchronization;±2%(settable±1% on the control panel) | ||||||||
Total harmonic distortion | 3%(linear load) | ||||||||
Short circuit current | Short current for 0.1s(200%current) | ||||||||
Overload capacity | 110% / 125% / 150% rated current 300min / 10min / 1min | ||||||||
Battery |
| ||||||||
Battery | Maintenance free lead-acid cell | ||||||||
DC Voltage | 384VDC | 432VDC | 480VDC | ||||||
Bypass |
| ||||||||
Type | Static state manual maintenance bypass | ||||||||
Input Phase | 3 phase 4 wire and ground | ||||||||
Input voltage range | ±15%(the front control panel selectable) | ||||||||
Input frequency range | ±1%~±5% the front control panel selectable | ||||||||
Transfer time | Inverter / bypass transfer switch time(Overload):0ms inverter / bypass transfer switch time(fault inverter)1ms | ||||||||
Overload capacity(10min) | 170% | 180% | 170% | 170% | 170% | 140% | 130% | 125% | 125% |
System |
| ||||||||
Remote signaling | Dry contact(battery low, battery discharging, bypass /fault); output 12Vdc/80mA | ||||||||
Remote control | EPO and bypass | ||||||||
Communication interface | RS232(SNMP, modem optional) | ||||||||
Running temperature | 0-40 degree Celsius | ||||||||
Relative Humidity | Less than 95%(without condensing) | ||||||||
Altitude | 1000m output nominal power (with increase of 100m,it will reduce output of 1%)max 4000m | ||||||||
Noise at 1M | less than 60dB | ||||||||
Inverter Efficiency | 92% | 93% | |||||||
Degree of protection | IP20 | ||||||||
Applicable Standards | EN50091-1-EMC EN50091-2liv.A | ||||||||
Optional | Isolating transformer | ||||||||
Harmonic wave suppression filter | |||||||||
Parallel modules can be up to six | |||||||||
Net weight(Kg) | 200 | 230 | 230 | 330 | 330 | 520 | 555 | 900 | 900 |
Gross weight(Kg) | 230 | 260 | 260 | 360 | 360 | 580 | 615 | 970 | 970 |
Packing(W×D×H) | 660×860×1430 | 950×890×1620 | 1200×810×1540 |
TianXin Electrical Co., Ltd. is a leading internationalmanufacturer of high quality power supply testing equipment, located in China. At TianXin, we can supply you high quality power supplytesting equipment such as AC automatic voltage regulator, uninterruptible powersupply, solar inverter, DC power supply and batterycharger.