The CO2 fractional laser system can emit a laser beam of 10.6μm in wavelength and divide it into tiny beams, forming a small image point processing area at the treatment area.
This laser can scan deep into the dermis, so the biological tissue will be thermally coagulated, vaporized and carbonized, stimulating the regeneration of a large amount of collagen. This makes the skin look healthier. Since there is no bleeding during the treatment using CO2 laser resurfacing equipment, this method is highly safe. The area of treatment will heal quickly, effectively avoiding infection. Therefore, it can be applied to any part of the body.
Scope of treatmentCosmetic use | Wrinkles, sagging skin |
Pigmentation disorder | |
Capillaries dilation (red spot) | |
Sunburn(brown spot) | |
Coarse pores, rough skin | |
Scar (resulting from acnes, burns, scalds and operations) | |
Medical use | Actinic keratosis (sunburn damage, precancerous lesions) |
Seborrheic keratosis (sunburn damage, precancerous lesions) | |
Sebaceous hyperplasia (yellow, lustrous projections on the face) | |
Rhinophyma (nasal swelling caused by excessive tissue growth) | |
Epidermal chloasma | |
Gynecology | Stress incontinence |
Vaginal inflammation | |
Mild to moderate prolapse of uterus | |
Fleshy vulva | |
Vaginal relaxation |
Laser source | USA RF Laser Tube (Manufactured by Coherent America) |
Working Mode | Fractional Mode Continuous Wave Mode (CW) Pulse Mode (single and repeated) Ultra Pulse Mode |
Laser Wavelength | 10600nm |
Power of laser generator | Max 60W |
Output Power | 1-30W |
Focus Diameter | ≤0.1-1.2 mm |
Treatment Depth | Max 2mm |
Aiming Beam | Red Diode laser (650nm,≤5mW) |
Delivery System | 7-Articulated Arm |
Scanning Area | Max 20×20mm |
Scanning shape | Ellipse, Rectangular, Triangular, Line, Square, Hexagon |
Scanning mode | Sequence Mode, Middle split Mode, Random Mode |
Smoke Exhausting System | Built-in air blow |
Cooling system | Air Cooling |
Environmental temperature | 5°C~40°C |
Relative Humidity | ≤80% |
Power Supply | ~220V±22V, 50Hz±1Hz |
Dimension | 450mm×550mm×1400mm |
Weight | 40kg |
Scanning mode | Energy of each laser shot | Interval | Treatment density | Scanning area | Repetition | Course of treatment |
Wrinkle reduction | 12.5-15mj | 1-2ms | 1.56-6.25% | Square; Straight line | Repeat 3-4 times until the skin is whitened | 1-2 rounds for shallow wrinkles; 4-5 rounds for deep wrinkles. |
Scar revision | 7.5-15mj | 1-2ms | 1.56-6.25% | Circle 0.2*0.2mm, 0.5*0.5mm | Repeat 3-4 times until the skin is whitened | 2-3 rounds for shallow scars; 4-5 rounds for deep wrinkles |
Hemangioma removal | 12.5-15mj | 1-2ms | 1.56-2.89% | Square | Repeat 3-4 times until the skin is whitened | 2-3 rounds for small hemangiomas; 4-5 rounds for big hemangiomas |
Pore tightening | 7.5-15mj | 1-2ms | 1.56-6.25% | Circle | Repeat for 3-4 times until the skin is whitened | 2-3 rounds for mild cases; 4-5 rounds for serious cases |
Mole removal | >15mj | 1-2ms | 25% | Circle | Repeat 3-4 times until the skin is whitened and slightly bleed | 2-3 rounds for mild cases; 4-5 rounds for serious cases |
Vagina contracting | 30mj | 1-2ms | 1.56%, | Circle4*4mm | Repeat 1-2 times | 2-3 rounds |
Vaginal inflammation | 20mj | 1-2ms | 2.89%, | Circle4*4mm | Repeat 2 times | 2-3 rounds |
Attentions:
① Energy should be reduced properly in case of mild situations, and increased in case of serious situations. The patient's tolerance should be considered at the same time.
② When used in gynecological therapy, the maximum energy should not exceed 40mj.