Note:*Configured when HE>6000.
Item | Specification | Notes | ||
Nominal Handrail Width (mm) | 1200 | 1000 | 800* | |
Nominal Handrail Width (mm) | 1280 | 1080 | 880 | JS-B/JS-BF, JS-LB/JS-LBF |
1208 | 1008 | / | JS-SB/JS-SBF | |
1260 | 1060 | 860 | JP-B/JP-BF | |
Width of Step or Pedal (mm) | 1000 | 800 | 600 | |
Theoretical Transportation Capacity(people/hour) | 9000 | 6750 | 4500 | |
Series Model | JS-B/JS-BF, JS-LB/JS-LBF, JS-SB/ JS-SBF, JP-B/JP-BE | |||
Inclination Angle | 30,35 | |||
Speed(m/s) | 0.5 | |||
Lifting Height(mm) | 2241~9500 | When inclination angle is 30° | ||
2571~6000 | When inclination Angle is 35° | |||
Drive Power | 380V50Hz 3 Phases | |||
Lighting Power | 220V50Hz Single Phase | |||
Horizontal moving distance Of steps(mm) | Horizontal 2 Steps;Horizontal 3 Steps;Horizontal 4 Steps | When lifting height Is<=6000mm | ||
Horizontal3 Steps; Horizontal 4 Steps | When lifting height Is>6000mm | |||
Operation Environment | In Door | Please contact with Shanghai Mitsubishi Elevator Co.Ltd.(SMEC)for outdoor use. | ||
Passenger Photoelectric Type | Built-in Skirt Panel Photoelec- tric | Specification for varble frequency, optional configured for single elevator, Multiple elevators. | ||
External Photoelectric Column | Specification for variable frequency optional configured for single elevator. Please contact with Shanghai Mitsubshi Elevator Co.,Ltd. (SMEC) in the condition of multiple elevators. |
Note:*This specification is not available for Js-SB/JS-SBF.
Drive Power Capacity(3 Phases)
Nominal Handrail Width(mm) | Lifting Height(mm) | Drive Power Capaclty |
1200 | HE<=4500 | 8 |
4500<=6500<=6500 | 10.4 | |
6500<=9500<=9500 | 15.4 | |
1000 | HE<=5500 | 8 |
5500<=6800<=6800 | 10.4 | |
6800<=9500<=9500 | 15.4 | |
800 | HE<=6500 | 8 |
6500<=9500<=9500 | 10.4 | |
Lighting Power Capacity(Single Phase) | ||
Series Model | Lifting Height(mm) | Lighting Power Capacity |
JS-LB/JS-LBF | HE<=4000 | 2 |
4000<=6000<=6000 | 2.3 | |
6000<=9500<=9500 | 2.5 | |
JS-B/JS-BF | HE<=9500 | 1.3 |
JS-SB/JS-SBF | HE<=9500 | 1.3 |
JP-B/JP-BF | HE<=9500 | 1.3 |
Item | Standard | Optional | Notes |
TJ(MM)* | 2560 | 2560 ~ 5260 | HE<=6000mm/INC30°/ STEPHU2 |
2970 | 2970 ~ 5670 | HE<=6000mm/INC30°/ STEPHU3 | |
3380 | 3380 ~ 6080 | HE<=6000mm/INC30°/ STEPHU4 | |
2600 | 2600 ~ 5300 | HE<=6000mm/INC35°/ STEPHU2/TK>=2350mm | |
3010 | 3010 ~ 5710 | HE<=6000mm/INC35°/ STEPHU3/TK>=2350mm | |
3420 | 3420 ~ 6120 | HE<=6000mm/INC35°/ STEPHU4/TK>=2350mm | |
2375 | 2375 ~ 2684 | HE<=6000mm/INC35°/ STEPHU2/TK>=2350mm | |
2970 | 2970 ~ 5670 | 6001<=HE<=6500/STEPHU3 BNW1000,1200 | |
3170 | 3170 ~ 5670 | 6001<=HE<=6500/STEPHU3 BNW800 | |
3380 | 3380 ~ 6080 | 6001<=HE<=6500/STEPHU4 BNW1000,1200 | |
3580 | 3580 ~ 6080 | 6001<=HE<=6500/STEPHU4 BNW800 | |
3450 | 3450 ~ 6150 | 6501<=HE<=9500/STEPHU3 | |
3860 | 3860 ~ 6560 | 6501<=HE<=9500/STEPHU4 | |
TK(mm)* | 2290 | 2290 to 5000 | HE<=6000/INC30°/STEPHU2 |
2700 | 2700 ~ 5410 | HE<=6000/INC30°/STEPHU3 | |
3110 | 3110 ~ 5820 | HE<=6000/INC30°/STEPHU4 | |
2350 | 2265 ~ 5060 | HE<=6000/INC35°/STEPHU2 | |
2760 | 2760 ~ 5470 | HE<=6000/INC35°/STEPHU3 | |
3170 | 3170 ~ 5880 | HE<=6000/INC35°/STEPHU4 | |
FJ(mm) | 1030 | HE<=6500 | |
1100 | 6501<=HE<=9500 | ||
FK(mm) | 1030 | ||
FC(mm) | 915 | ||
Escalator Width ( mm) | 1550 | BNM1200 | |
1350 | BNM1000 | ||
1150 | BNM800 | ||
THE | 0 ~ 11000 | BNM1200: intermediate support number 1 | |
0 ~ 11400 | BNM1000: intermediate support number 1 | ||
0 ~ 11700 | BNM800: intermediate support number 1 | ||
LB | 0 ~ 11000 | BNM1200: intermediate support number 1 | |
0 ~ 11400 | BNM1000: intermediate support number 1 | ||
0 ~ 11700 | BNM800: intermediate support number 1 |
Notes:
1. Please contact with relative salesman of Shanghai Mitsubishi Elevator Co.,Ltd. (SMEC)
2. Min.values of TJ.TK size are recommended.
Shanghai SMEC Enterprise Co.,Ltd.
200070