Home Vacuum Circuit Breakers

Vacuum Circuit Breakers

Thanks to the cooperation with Siemens and Xiamen University, South China Electric has successfully developed and manufactured VSCE (I) vacuum circuit breaker. By adopting Siemens’ latest vacuum arc-extinguishing chamber and improved operating system, our vacuum interrupter ensures a good performance and has been universally used. All parts and components of our circuit breaker are precisely manufactured and well assembled, realizing an excellent coordination with minimized friction between moving parts, which is of vital importance to reliable operation. That’s why VSCE (I) vacuum circuit interrupter is featured by high insulating level, good vacuum leakproofness and exceptional endurance. This distinguished circuit interrupter has found wide application in energy infrastructure construction, power plant, commercial and residential buildings, industries and other fields.

Vacuum Circuit Breakers

Features
(1) High current breaking capacity
(2) Good insulation strength
(3) Lower contact resistance
(4) High vacuum degree
(5) Low chopping current
(6) Long lifespan
All vacuum circuit breakers have passed routine test, type test and special test by national labs. They also comply with national standards or client’s requirement. We will pick out unqualified products before delivery.


Parameters


S.N.. Item Unit Technical data
1. Rated voltage kV 12
2. Rated insulation level Rated short-time power-frequency withstand voltage (1 min) 42
3. Rated lightning impulse withstand voltage (peak) 75
4. Rated frequency Hz 50
5. Rated current A 630 630 1250 1250
1250 1250 1600 1600
2000 2000
2500 2500
3150 3150
4000 4000
6. Rated short-circuit breaking current kA 20 25 31.5 40
7. Rated short-circuit withstand current 20 25 31.5 40
8. Rated peak withstand current 50 63 31.5 100
9. Rated short-circuit making current (peak) 50 63 80 100
10. 4s thermal stability current 20 25 31.5 40
11. Rated dynamic stability current 50 63 80 100
12. Rated closing surge of capacitor bank 12.5 (frequency ≤ 1000Hz)
13. Rated breaking current of single/back-to-back capacitor bank A 630/400
14. Rated short-circuit continuous current S 4
15. Power-frequency withstand voltage of secondary circuit V 2000
16. Rated operating voltage Closing coil AC 110/220 DC 110/220
Opening coil AC 110/220 DC 110/220
Energy storage motor AC 110/220 DC 110/220
17. Opening time (rated voltage) ms 20~50
18. Closing time (rated voltage) 30~70
19. Allowable accumulative wearing thickness of moving and fixed contacts mm 3
20. Energy storage time s < 15
21. Clearance between open contacts mm 6 ± 0.5 8 ± 1
22. Contact travel s 3~4
23. Bouncing time of contact closing ms < 2
24. Asynchronous opening and closing of three-phase contacts < 2
25. Average opening speed (0-1/3 opening) ms 0.9~1.3
26. Average closing speed (0-1/3 opening, contact closed) 0.4~1.0
27. Rebounding amplitude of contact opening mm < 2
28. Resistance of primary conductive circuit μΩ < 55 (630A)
< 45 (1250A)
< 35 (1600A~2000A)
< 25 (above 2500)
29. Contact pressure of contact closing N 2000 ± 200 (20kA)
2400 ± 200 (25kA)
3100 ± 200 (31.5kA)
4750 ± 200 (40kA)
30. Operation sequence Opening-θ-closing and opening-180s-closing and opening


Technical Parameters of Energy Storage Motor


Mode Rated voltage Rated input power (W) Normal operating voltage range Energy storage time at rated voltage (s)
ZYJ66-8D 220V 90 85~100% of rated voltage ≤ 10


Technical Parameters of Closing and Opening Electromagnet


Items Closing electromagnet Opening electromagnet Latching electromagnet
Rated operating voltage (V) 220 220 220
Rated operating current (A) 1.1 1.1 25mA
Rated operating power (W) 242 242 2.7
Normal operating voltage range 85%-110% of rated voltage 65%-110% of rated voltage, opening will fail if the voltage is lower than 30% of rated voltage --


Model of Siemens Vacuum Arc Extinguishing Chamber for the Circuit Breaker


S.N.. Rated current (A) Rated breaking current (kA) Model of vacuum arc extinguishing chamber
1 630 20 VSA12-0-20
2 630, 1250 25/31.5 VSA12-0-25/VSA12-0-31.5
3 3150, 4000 40 VSA12-0-40


Supply Scope of VSCE (I) Intelligent Environment-Friendly Solid-Enveloped Vacuum Circuit Breaker


In (A) 630 1250
Isc (kA) 20 25 31.5 25 31.5 40 50
In (A) 1600 2000
Isc (kA) 25 31.5 40 50 31.5 40 50
In (A) 2500 3150
Isc (kA) 31.5 40 50 31.5 50 50
In (A) 4000
Isc (kA) 31.5 40 50

Recommended Products